Skip to main content
QUICK REVIEW

[Paper Review] Three-Omega Thermal-Conductivity Measurements with Curved Heater Geometries

Gabriel R. Jaffe, Keenan J. Smith|arXiv (Cornell University)|May 4, 2020
Thermal properties of materialsMaterials Science27 references5 citations
TL;DR

This study demonstrates that three-omega thermal conductivity measurements remain accurate even with heater wires curved to radii as small as 200 µm, with thermal conductivity measurements differing by only 0.2% from straight wires. The work establishes that wire curvature has negligible impact on thermal resistance measurements as long as the thermal penetration depth is no more than 4.3 times the minimum radius of curvature, providing critical design guidelines for three-omega experiments on complex or residue-laden samples like 2D materials and nanomembranes.

ABSTRACT

The three-omega method, a powerful technique to measure the thermal conductivity of nanometer-thick films and the interfaces between them, has historically employed straight conductive wires to act as both heaters and thermometers. When investigating stochastically prepared samples such as two-dimensional materials and nanomembranes, residue and excess material can make it difficult to fit the required millimeter-long straight wire on the sample surface. There are currently no available criteria for how diverting three-omega heater wires around obstacles affects the validity of the thermal measurement. In this Letter, we quantify the effect of wire curvature by performing three-omega experiments with a wide range of frequencies using both curved and straight heater geometries on SiO$_2$/Si samples. When the heating wire is curved, we find that the measured Si substrate thermal conductivity changes by only 0.2%. Similarly, we find that wire curvature has no significant effect on the determination of the thermal resistance of a $\sim$65 nm SiO$_2$ layer, even for the sharpest corners considered here, for which the largest measured ratio of the thermal penetration depth of the applied thermal wave to radius of curvature of the heating wire is 4.3. This result provides useful design criteria for three-omega experiments by setting a lower bound for the maximum ratio of thermal penetration depth to wire radius of curvature.

Motivation & Objective

  • To determine the maximum allowable curvature in three-omega heater wires without introducing significant error in thermal conductivity measurements.
  • To evaluate the impact of wire curvature on the accuracy of thermal resistance measurements in SiO2/Si samples.
  • To establish design criteria for routing three-omega heaters around obstacles in stochastic samples such as 2D materials and nanomembranes.
  • To quantify how curvature affects the three-omega method's sensitivity to thermal penetration depth and geometric non-uniformity.

Proposed method

  • Performed three-omega experiments on SiO2/Si substrates with both straight and curved heater geometries across a wide frequency range.
  • Used electron beam lithography and liftoff to fabricate 70 nm thick Au/Ti heaters with controlled radii of curvature down to 200 µm.
  • Measured thermal resistance and substrate thermal conductivity using voltage probes and lock-in amplification at the third harmonic (3ω) of the excitation frequency.
  • Calculated thermal penetration depth using the formula λ = √(D / 2ω), where D is thermal diffusivity of the substrate.
  • Compared thermal resistance differences between 220 nm and 285 nm SiO2 films using straight and curved heaters to assess geometric effects.
  • Used differential measurement to isolate thin-film thermal resistance by subtracting substrate contributions.

Experimental results

Research questions

  • RQ1How does wire curvature affect the measured thermal conductivity of a Si substrate in three-omega experiments?
  • RQ2What is the maximum allowable ratio of thermal penetration depth to wire radius of curvature before measurement accuracy degrades?
  • RQ3Does curvature significantly alter the determination of thin-film thermal resistance in a multilayer system?
  • RQ4To what extent do geometric differences in heater paths affect the differential measurement of thermal resistance in three-omega setups?
  • RQ5Can curved heater geometries be reliably used in three-omega measurements on complex, residue-laden samples like 2D materials?

Key findings

  • The measured Si substrate thermal conductivity differed by only 0.2 Wm⁻¹K⁻¹ between straight and curved heater geometries.
  • The difference in cross-plane thermal resistance between 220 nm and 285 nm SiO2 films was as low as 4.3 m²K W⁻¹ when comparing curved and straight wires.
  • Even when the thermal penetration depth was 4.3 times larger than the minimum radius of curvature, no significant deviation in thermal resistance was observed.
  • The thermal conductivity of the SiO2 film was calculated as 1.91 ± 0.24 Wm⁻¹K⁻¹, which is 44% higher than literature values, likely due to increased interface resistance from plasma etching.
  • No measurable effect of wire curvature was found on the determination of thermal resistance, even for sharp corners with high curvature-to-penetration depth ratios.
  • The results establish a lower bound: wire curvature is acceptable as long as the thermal penetration depth is ≤4.3 times the minimum radius of curvature.