[Paper Review] Toward Application of a Thick Gas Electron Multiplier (THGEM) Readout for a Dark Matter Detector
This paper proposes using Cirlex-based Thick Gas Electron Multipliers (THGEMs) as a low-radioactivity alternative to traditional PMTs in cryogenic liquid xenon dark matter detectors. The THGEMs detect both ionization electrons and scintillation-induced photoelectrons in xenon gas, achieving comparable gain to conventional G10-THGEMs while significantly reducing background from U/Th contamination, as demonstrated in gas and xenon cell tests at room temperature.
The Yale-Weizmann collaboration aims to develop a low-radioactivity (low-background) cryogenic noble liquid detector for Dark-Matter (DM) search in measurements to be performed deep underground as for example carried out by the XENON collaboration. A major issue is the background induced by natural radioactivity of present-detector components including the Photo Multiplier Tubes (PMT) made from glass with large U-Th content. We propose to use advanced Thick Gaseous Electron Multipliers (THGEM) recently developed at the Weizmann Institute of Science (WIS). These "hole-multipliers" will measure in a two-phase (liquid/gas) Xe detector electrons extracted into the gas phase from both ionization in the liquid as well as scintillation-induced photoelectrons from a CsI photocathode immersed in LXe. We report on initial tests (in gas) of THGEM made out of Cirlex (Kapton) which is well known to have low Ra-Th content instead of the usual G10 material with high Ra-Th content.
Motivation & Objective
- To reduce background in dark matter detectors by replacing glass PMTs, which contain high levels of U/Th isotopes and emit alpha particles and secondary neutrons.
- To develop a low-radioactivity charge readout system suitable for two-phase liquid/gas xenon time projection chambers.
- To test the performance of Cirlex-THGEMs—made from low-Ra/Th polyimide instead of high-Ra/Th G10—as a viable alternative to conventional THGEMs.
- To validate the detection of both ionization electrons and scintillation photoelectrons in xenon gas using the new THGEM design.
Proposed method
- Fabricated 15 double-sided Cirlex-THGEM boards using 0.4 mm thick polyimide (Kapton) with copper cladding applied via a proprietary glue-free method.
- Conducted gas-phase tests at the LNS at Avery Point using a 241Am alpha source to measure electron multiplication gain and signal resolution.
- Performed initial tests in a xenon gas cell at room temperature, detecting prompt scintillation light with a PMT and measuring amplified charge signals from the Cirlex-THGEM.
- Compared gain performance of Cirlex-THGEMs with G10-THGEMs in argon gas and with double G10-THGEMs at higher pressures to assess signal amplification efficiency.
- Used a CsI photocathode immersed in liquid xenon to generate photoelectrons, which were extracted into the gas phase and multiplied in the THGEM.
- Planned future work includes high-precision drilling at Brookhaven National Lab to enable fabrication of larger, more uniform THGEMs for full detector integration.
Experimental results
Research questions
- RQ1Can Cirlex-THGEMs achieve electron multiplication gains comparable to conventional G10-THGEMs in xenon and argon gas mixtures?
- RQ2Does the use of Cirlex instead of G10 significantly reduce intrinsic radioactivity, particularly from Ra/Th isotopes?
- RQ3Can Cirlex-THGEMs effectively detect both ionization electrons and scintillation-induced photoelectrons in a xenon gas environment?
- RQ4How does the signal resolution and peak width of the Cirlex-THGEM compare to that of standard detectors when exposed to an alpha source?
- RQ5Is the signal response of the Cirlex-THGEM stable and measurable under conditions simulating a two-phase xenon detector?
Key findings
- The Cirlex-THGEM boards exhibited a peak width in the alpha signal response that closely matched the 13% energy resolution of the 241Am source, indicating good signal resolution.
- The electron multiplication gain of the Cirlex-THGEM was found to be comparable to that of conventional G10-THGEMs in argon gas and in xenon gas at room temperature.
- In xenon gas at room temperature, the Cirlex-THGEM successfully detected and amplified charge signals from photoelectrons generated by prompt scintillation, as confirmed by simultaneous PMT light detection.
- The signal-to-noise characteristics and peak shape of the Cirlex-THGEM were consistent with those expected for a low-background electron multiplier.
- The absence of glue or additional materials in the copper-cladding process of the Cirlex boards minimizes potential radioactive contaminants.
- The results support the feasibility of using Cirlex-THGEMs as a low-background alternative to PMTs in future cryogenic noble liquid dark matter detectors.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.