[Paper Review] Towards Radar-Agnostic Gait Analysis Across UWB and FMCW Systems

Charalambos Hadjipanayi, Maowen Yin|arXiv (Cornell University)|Jan 7, 2026
Advanced SAR Imaging TechniquesEngineering0 citations
TL;DR

The paper validates a unified processing framework for spatiotemporal gait analysis that works across collocated UWB and FMCW radars, achieving high agreement with motion capture and strong inter-modality consistency.

ABSTRACT

Radar sensing has emerged in recent years as a promising solution for unobtrusive and continuous in-home gait monitoring. This study evaluates whether a unified processing framework can be applied to radar-based spatiotemporal gait analysis independent of radar modality. The framework is validated using collocated impulse-radio ultra-wideband (IR-UWB) and frequency-modulated continuous-wave (FMCW) radars under identical processing settings, without modality-specific tuning, during repeated overground walking trials with 10 healthy participants. A modality-independent approach for automatic walking-segment identification is also introduced to ensure fair and reproducible modality performance assessment. Clinically relevant spatiotemporal gait parameters, including stride time, stride length, walking speed, swing time, and stance time, extracted from each modality were compared against gold-standard motion capture reference estimates. Across all parameters, both radar modalities achieved comparably high mean estimation accuracy in the range of 85-98%, with inter-modality differences remaining below 4.1%, resulting in highly overlapping accuracy distributions. Correlation and Bland-Altman analyses revealed minimal bias, comparable limits of agreement, and strong agreement with reference estimates, while intraclass correlation analysis demonstrated high consistency between radar modalities. These findings indicate that no practically meaningful performance differences arise from radar modality when using a shared processing framework, supporting the feasibility of radar-agnostic gait analysis systems.

Motivation & Objective

  • Demonstrate that a single processing framework can extract gait parameters from different radar modalities without modality-specific tuning.
  • Quantify agreement of radar-derived gait parameters with gold-standard motion capture (MOCAP).
  • Assess inter-radar consistency between UWB and FMCW systems under identical processing settings.

Proposed method

  • Collocated data collection with two radar modalities: IR-UWB (7.29 GHz, 1.4 GHz BW) and FMCW (60 GHz).
  • Apply an identical offline processing pipeline to both modalities to obtain range–Doppler–time representations and RDT frames.
  • Use high-pass and adaptive exponential moving-average filtering to suppress clutter, followed by STFT-based Doppler analysis to derive gait-relevant envelopes.
  • Automatic walking-segment detection via short-time autocorrelation on feet-speed trajectories to produce a modality-independent walking mask.
  • Detect gait events (HS, TO) from radar-derived feet velocity and compute spatiotemporal gait parameters (stride time/length, walking speed, swing/stance times).
  • Compare radar estimates to MOCAP ground truth using correlation, Bland–Altman, and ICC analyses.

Experimental results

Research questions

  • RQ1Can a unified processing framework yield comparable gait parameter estimates from UWB and FMCW radars when applied without modality-specific tuning?
  • RQ2What is the level of agreement between radar-derived gait parameters and gold-standard MOCAP across modalities?
  • RQ3How consistent are gait parameter estimates between UWB and FMCW radars under the same processing pipeline?

Key findings

  • Both FMCW and UWB radars achieve high correlation with MOCAP for torso range/velocity (≈0.999) and feet trajectories (≈0.90–0.99 after processing).
  • Gait event detection accuracy exceeds 99.7% for HS/TO locations with small range-time differences between modalities (mean HS time and HS range differences ≈0.08–0.19%).
  • Mean gait-parameter accuracy differences between modalities range from 0.3% to 4.1% across parameters, with walking velocity showing the largest inter-modality difference (4.1%).
  • Bland–Altman and correlation analyses indicate near-zero bias and strong agreement with MOCAP for most parameters; walking speed shows near-perfect inter-modality agreement (r ≈ 0.98, ICC ≈ 0.97).
  • Correlation between FMCW and UWB estimates is high for all parameters (e.g., walking speed r ≈ 0.98, stride time r ≈ 0.88).
  • The results support radar-agnostic gait analysis using a shared pipeline.