[Paper Review] Towards unraveling calibration biases in medical image analysis
This paper investigates calibration biases in AI models for skin lesion classification, revealing that common calibration metrics like Expected Calibration Error (ECE) are systematically biased by sample size imbalances between demographic subgroups—particularly light- vs. dark-skinned patients. The study demonstrates that such biases can lead to spurious fairness assessments, and recommends using robust metrics like Delta-Brier or Delta-CE in low-resource subgroups to ensure reliable fairness audits in medical AI.
In recent years the development of artificial intelligence (AI) systems for automated medical image analysis has gained enormous momentum. At the same time, a large body of work has shown that AI systems can systematically and unfairly discriminate against certain populations in various application scenarios. These two facts have motivated the emergence of algorithmic fairness studies in this field. Most research on healthcare algorithmic fairness to date has focused on the assessment of biases in terms of classical discrimination metrics such as AUC and accuracy. Potential biases in terms of model calibration, however, have only recently begun to be evaluated. This is especially important when working with clinical decision support systems, as predictive uncertainty is key for health professionals to optimally evaluate and combine multiple sources of information. In this work we study discrimination and calibration biases in models trained for automatic detection of malignant dermatological conditions from skin lesions images. Importantly, we show how several typically employed calibration metrics are systematically biased with respect to sample sizes, and how this can lead to erroneous fairness analysis if not taken into consideration. This is of particular relevance to fairness studies, where data imbalance results in drastic sample size differences between demographic sub-groups, which, if not taken into account, can act as confounders.
Motivation & Objective
- To investigate how sample size imbalances between demographic subgroups affect the reliability of calibration metrics in medical image analysis.
- To assess whether commonly used calibration metrics like Expected Calibration Error (ECE) produce misleading fairness evaluations in the presence of data imbalance.
- To identify calibration metrics that are less sensitive to finite sample sizes for more accurate fairness auditing in underrepresented groups.
- To evaluate the interaction between model calibration quality and sample size bias in fairness assessments.
- To advocate for inclusive datasets and robust calibration metrics to ensure equitable AI in dermatological imaging.
Proposed method
- Evaluated multiple calibration metrics (e.g., ECE, Brier Score, Delta-Brier, Delta-CE) on skin lesion classification models trained on real-world dermatological datasets with imbalanced skin tone subgroups.
- Analyzed the sensitivity of each metric to sample size differences between light-skinned and dark-skinned patient groups using controlled experiments and real data.
- Used the PAD-UFES-20 dataset with 1,494 images and Fitzpatrick skin type labels to assess fairness across demographic subgroups.
- Compared naive metric application with resampling and robust metric strategies to mitigate sample size bias.
- Investigated the interplay between model calibration quality and metric sensitivity to sample size, especially after model re-calibration.
- Proposed a two-component interpretation of calibration metrics: one driven by finite sample size effects, and another reflecting true model de-calibration.

Experimental results
Research questions
- RQ1How do common calibration metrics behave under extreme sample size imbalances between demographic subgroups in dermatological image analysis?
- RQ2To what extent do metrics like Expected Calibration Error (ECE) produce spurious fairness conclusions due to finite sample size effects?
- RQ3Which calibration metrics are least affected by sample size differences and thus more suitable for fairness audits in low-resource subgroups?
- RQ4How does model re-calibration affect the sensitivity of calibration metrics to sample size bias?
- RQ5Can robust metrics such as Delta-Brier or Delta-CE provide more reliable fairness assessments in imbalanced medical imaging datasets?
Key findings
- Common calibration metrics like Expected Calibration Error (ECE) are highly sensitive to sample size and systematically worsen with fewer samples, leading to biased fairness assessments.
- The study found that calibration metric biases are most pronounced in well-calibrated models, particularly after re-calibration, where sample size effects dominate.
- Metrics such as Delta-Brier and Delta-CE showed lower sensitivity to sample size and are therefore more reliable for fairness audits in underrepresented groups.
- Even with no significant differences in discrimination performance (e.g., AUC or accuracy), calibration disparities can emerge due to metric bias, not actual model bias.
- The interaction between model calibration quality and sample size leads to a two-component behavior in metrics: one driven by finite sample effects, and another by true model miscalibration.
- The scarcity of labeled skin tone data in open databases—especially for dark-skinned individuals—limits the ability to perform robust fairness evaluations, highlighting the need for inclusive datasets.

Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.