Skip to main content
QUICK REVIEW

[Paper Review] Transfer Learning for Oral Cancer Detection using Microscopic Images

Rutwik Jayant Palaskar, Renu Vyas|arXiv (Cornell University)|Nov 23, 2020
AI in cancer detectionComputer Science16 references14 citations
TL;DR

This study proposes a transfer learning framework using pre-trained CNNs—specifically Inception V3, ResNet, and MobileNet—on a newly collected, augmented dataset of oral squamous cell microscopic images to improve early oral cancer detection. The approach achieves a 10–15% absolute accuracy gain over simple CNN baselines, with Inception V3 fine-tuned and augmented achieving 91.13% accuracy and 88% F1-score, demonstrating strong performance for histopathological classification in low-data regimes with class imbalance.

ABSTRACT

Oral cancer has more than 83% survival rate if detected in its early stages, however, only 29% of cases are currently detected early. Deep learning techniques can detect patterns of oral cancer cells and can aid in its early detection. In this work, we present the first results of neural networks for oral cancer detection using microscopic images. We compare numerous state-of-the-art models via transfer learning approach and collect and release an augmented dataset of high-quality microscopic images of oral cancer. We present a comprehensive study of different models and report their performance on this type of data. Overall, we obtain a 10-15% absolute improvement with transfer learning methods compared to a simple Convolutional Neural Network baseline. Ablation studies show the added benefit of data augmentation techniques with finetuning for this task.

Motivation & Objective

  • To address the critical challenge of low early detection rates in oral cancer (currently only 29%) by automating histopathological classification using deep learning.
  • To develop and evaluate transfer learning models on a newly collected, high-quality dataset of oral squamous cell carcinoma and normal epithelium images.
  • To investigate the impact of data augmentation and fine-tuning on model performance in the context of limited medical imaging data.
  • To evaluate and compare multiple class imbalance handling techniques—oversampling, undersampling, and loss weighting—for improving model fairness and generalization.
  • To validate model robustness through multi-site testing using data from a separate clinical source.

Proposed method

  • Transfer learning was applied using pre-trained ImageNet models: MobileNet, ResNet-50, and Inception V3, fine-tuned on a custom dataset of 1224 histopathological images.
  • Data augmentation techniques such as rotation, flipping, and scaling were applied to increase training diversity and improve generalization.
  • Fine-tuning was performed by replacing the final classification layer and training the last few layers with a lower initial learning rate.
  • Three class imbalance mitigation strategies were evaluated: oversampling the minority class, undersampling the majority class, and class-weighted loss during training.
  • Model evaluation used standard metrics: accuracy, precision, recall, F1-score, and AUC-ROC, with confusion matrix analysis to assess class-wise performance.
  • Multi-site testing was conducted using 123 additional OSCC images from a collaborating dental hospital, combined with non-cancerous images from the original test set.

Experimental results

Research questions

  • RQ1How do state-of-the-art transfer learning models perform on classifying oral squamous cell carcinoma from normal epithelium in microscopic images?
  • RQ2What is the relative contribution of data augmentation and fine-tuning to model performance in this low-data medical imaging setting?
  • RQ3Which class imbalance handling technique—oversampling, undersampling, or loss weighting—yields the most balanced and accurate classification performance?
  • RQ4How generalizable are the models when tested on data from a different clinical site?
  • RQ5Which model architecture achieves the highest accuracy and robustness across multiple evaluation metrics?

Key findings

  • Inception V3 with both data augmentation and fine-tuning achieved the highest test accuracy of 91.13%, with 88% F1-score and 87% AUC-ROC, outperforming all other models.
  • Transfer learning with fine-tuning alone improved accuracy by 10–15% over simple CNN baselines, with ResNet and Inception V3 showing the most significant gains.
  • Data augmentation provided measurable performance gains, especially when combined with fine-tuning, improving Inception V3’s accuracy from 89.52% to 91.13%.
  • Loss weighting outperformed oversampling and undersampling for the Large CNN, achieving a higher AUC-ROC (0.66) than oversampling (0.56), indicating better class balance.
  • Multi-site testing showed competitive performance across all transfer learning models, with Inception V3 achieving 83.66% accuracy, confirming model generalization across different data sources.
  • Confusion matrix analysis revealed that while both Large CNN and Inception V3 had similar true positive rates, the Large CNN significantly underperformed on true negatives, indicating poor specificity and class imbalance bias.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.