Skip to main content
QUICK REVIEW

[Paper Review] Transient Stability Assessment for Current Constrained and Unconstrained Fault Ride-Through in Virtual Oscillator Controlled Converters

M A Awal, Iqbal Husain|arXiv (Cornell University)|Nov 18, 2020
Microgrid Control and OptimizationEngineering23 references7 citations
TL;DR

This paper proposes a unified transient stability analysis framework for virtual oscillator controlled (uVOC) converters under both current-constrained and unconstrained fault ride-through (FRT) conditions. By introducing a novel phase-plane analysis using $̅{x}-x$ surfaces that jointly capture voltage and power angle dynamics, the method reveals that uVOC is not limited by a critical clearing angle—unlike second-order droop or VSM controllers—enabling robust FRT without stability loss even under severe current saturation.

ABSTRACT

Unified virtual oscillator controller (uVOC) inherits the rigorous analytical foundation offered by oscillator based grid-forming (GFM) controllers and enables fast over-current limiting and fault ride-through (FRT). Control design for effective FRT requires transient stability analysis. Existing transient stability analysis methods and studies are limited in either considering only current unconstrained scenarios or neglecting the simultaneous power angle and voltage dynamics. Under current-constrained faults, the voltage and power angle dynamics are strongly coupled and both play critical roles in determining transient stability. Therefore, decoupled analysis of the two, typically used in transient stability studies, does not offer comprehensive insight into the system dynamics. In this work, the overall FRT method for uVOC is presented and a comprehensive modeling and analysis method for transient stability is developed under both current-saturated and unsaturated symmetrical AC faults. We utilize phase-plane analysis of the overall system in a single graphical representation to obtain holistic insights into the coupled voltage and power angle dynamics. The FRT controller and the analysis method have been validated through simulations and hardware experiments. The results demonstrate that uVOC is not constrained by a critical clearing angle unlike droop and virtual synchronous machine (VSM) type second order controllers.

Motivation & Objective

  • To address the lack of comprehensive transient stability analysis for oscillator-based grid-forming converters under simultaneous voltage and power angle dynamics.
  • To develop a unified modeling and analysis method for both current-constrained and unconstrained symmetrical AC faults in uVOC-based converters.
  • To overcome the limitations of decoupled analysis methods that treat power angle and voltage dynamics separately.
  • To validate the proposed FRT controller and analysis framework through simulation and hardware experimentation.
  • To demonstrate that uVOC maintains transient stability without critical clearing angle constraints, even under current saturation.

Proposed method

  • Develops a comprehensive dynamic model of the uVOC-based converter system under symmetrical AC faults, including both current-saturated and unsaturated conditions.
  • Introduces a novel phase-plane analysis using $̅{x}-x$ surfaces to visualize the coupled dynamics of voltage ($V$) and power angle ($\delta$) in a single 3D graphical representation.
  • Employs a fault management subsystem within the uVOC controller that generates switching signals $x_f$ and $x_r$ to transition between normal and current-constrained operation modes.
  • Utilizes a first-order nonlinear time-domain controller structure that embeds current reference generation within the synchronizing oscillator, avoiding inner voltage/current loop saturation.
  • Validates the model and analysis through both electromagnetic transient simulations and hardware experiments on a single-phase equivalent system with scaled ratings.
  • Applies large-signal nonlinear analysis to assess stability under severe fault conditions, including limit-cycle behavior during current-saturated faults.

Experimental results

Research questions

  • RQ1How do coupled voltage and power angle dynamics affect transient stability in uVOC-based converters during current-constrained faults?
  • RQ2Can a unified phase-plane analysis method effectively capture the holistic dynamics of voltage and power angle under both current-saturated and unsaturated fault conditions?
  • RQ3Does uVOC maintain transient stability without being constrained by a critical clearing angle, even under current saturation?
  • RQ4How does the proposed FRT controller perform in hardware under severe voltage sag and over-current conditions?
  • RQ5What is the behavior of the system when no equilibrium point exists during a fault, particularly in terms of limit-cycle oscillations?

Key findings

  • The proposed $̅{x}-x$ phase-plane analysis provides a holistic, single-graphical representation of coupled voltage and power angle dynamics, overcoming limitations of traditional decoupled analysis.
  • uVOC-based converters exhibit no critical clearing angle constraint under both current-constrained and unconstrained faults, unlike second-order droop or VSM controllers.
  • Hardware experiments confirmed that during a 0.5 p.u. voltage sag, the converter entered current-limited operation, raised terminal voltage to 0.64 p.u., and maintained stability.
  • Under a 0.6 p.u. voltage sag, the converter remained within current limits, with terminal voltage rising to 0.94 p.u., and returned to normal operation after fault clearing.
  • In a severe fault condition (0.5 p.u. voltage sag), a limit-cycle response with a period of approximately 400 ms was observed, confirming the absence of a stable equilibrium point.
  • The system rapidly resumed normal operation within one cycle after fault clearance, demonstrating robust fault ride-through capability.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.