Skip to main content
QUICK REVIEW

[Paper Review] TRITIUM - A Real-Time Tritium Monitor System for Water Quality Surveillance

C.D.R. Azevedo, A. Baeza|arXiv (Cornell University)|Feb 14, 2019
Radiation Detection and Scintillator TechnologiesPhysics and Astronomy2 references10 citations
TL;DR

This paper presents the TRITIUM project, a real-time, in-situ tritium monitor for river water near nuclear power plants, using scintillating optical fibers read out by silicon photomultipliers (SiPMs) in coincidence mode to detect low-level tritium with high sensitivity. The system achieves sub-100 Bq/L detection capability through optimized fiber geometry, background rejection, and hyperpure water purification, with prototype validation demonstrating stable performance and a 10-fold signal improvement over earlier models.

ABSTRACT

In this work the development results of the TRITIUM project is presented. The main objective of the project is the construction of a near real-time monitor for low activity tritium in water, aimed at in-situ surveillance and radiological protection of river water in the vicinity of nuclear power plants. The European Council Directive 2013/51/Euratom requires that the maximum level of tritium in water for human consumption to be lower than 100 Bq/L. Tritium levels in the cooling water of nuclear power plants in normal operation are much higher than the levels caused by the natural and cosmogenic components, and may easily surmount the limit required by the Directive. The current liquid-scintillation measuring systems in environmental radioactivity laboratories are sensitive to such low levels, but they are not suitable for real-time monitoring. Moreover, there is no currently available device with enough sensitivity and monitoring capabilities that could be used for surveillance of the cooling water of nuclear power plants. A detector system based on scintillation fibers read out by photomultiplier tubes (PMTs) or silicon photomultiplier (SiPM) arrays is under development for in-water tritium measurement. This detector will be installed in the vicinity of Almaraz nuclear power plant (Spain) in Spring 2019. An overview of the project development and the results of first prototypes are presented.

Motivation & Objective

  • Develop a near real-time, in-situ tritium monitoring system for river water near nuclear power plants to ensure compliance with the EU Directive 2013/51/Euratom limiting tritium to 100 Bq/L.
  • Overcome limitations of current liquid scintillation methods, which require sample collection and are unsuitable for continuous, autonomous monitoring.
  • Design a detector with sufficient sensitivity to detect tritium levels below 100 Bq/L, even in the presence of cosmic and natural background radiation.
  • Implement a water purification system to maintain hyperpure water (conductivity ~10 µS/cm) and ensure no tritium loss during processing.
  • Achieve autonomous, continuous measurement with an alarm trigger for tritium levels exceeding 100 Bq/L within less than 10 minutes of measurement time.

Proposed method

  • Utilize unclad scintillating optical fibers (1 mm and 2 mm diameter) as the primary detection medium for low-energy beta particles from tritium decay.
  • Read out scintillation signals using silicon photomultipliers (SiPMs) or photomultiplier tubes (PMTs) in coincidence mode to suppress intrinsic detector noise.
  • Implement active and passive shielding—using plastic scintillators and lead bricks—to reject cosmic and natural background radiation.
  • Integrate a hyperpure water purification system with conductivity <10 µS/cm to prevent fiber fouling and preserve tritium activity during measurement.
  • Design a modular detector with 15 cylindrical cells, each containing 500 fibers (25 cm long, 1 mm diameter), read out by two SiPM arrays per cell in coincidence.
  • Use GEANT4 simulations to optimize fiber length, diameter, and geometric configuration for maximum energy deposition and detection efficiency.

Experimental results

Research questions

  • RQ1Can scintillating optical fibers without cladding detect low-energy beta particles from tritium decay with sufficient efficiency and signal-to-noise ratio?
  • RQ2What is the optimal fiber diameter and geometric configuration to maximize energy deposition from tritium decay electrons while minimizing signal loss?
  • RQ3Can coincidence detection using SiPMs or PMTs effectively suppress intrinsic detector noise and improve sensitivity below 100 Bq/L?
  • RQ4How does the performance of the detector system scale with the number of scintillating fibers and their surface condition?
  • RQ5Can a continuous-flow, hyperpure water system maintain tritium levels and enable 10-minute renewal cycles for real-time monitoring?

Key findings

  • GEANT4 simulations show that electrons from tritium decay deposit energy in 2 mm diameter unclad fibers with a peak around 12 keV, ranging from 2 to 18 keV, and that decay events occur within 5 µm of the fiber surface.
  • The TRITIUM-1 Aveiro prototype achieved a tenfold increase in tritium signal compared to the TRITIUM-0 prototype due to a higher number of fibers and optimized coincidence readout.
  • The detector prototype maintained a stable response over 9 months of continuous laboratory testing, demonstrating long-term reliability.
  • Low-energy detection was validated using a 55Fe source (5.9 keV photons), confirming the system's capability to detect signals near the 6 keV average energy of tritium beta decay.
  • The system successfully measured tritiated water at 108.11 MBq/L with clear signal separation from hyperpure water in data spectra, confirming sensitivity at levels far above the regulatory limit.
  • The hyperpure water purification system preserved tritium activity and enabled a 10-minute water renewal cycle, supporting real-time monitoring requirements.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.