Skip to main content
QUICK REVIEW

[Paper Review] Tumour ROI Estimation in Ultrasound Images via Radon Barcodes in Patients with Locally Advanced Breast Cancer

Hamid R. Tizhoosh, Mehrdad J. Gangeh|arXiv (Cornell University)|Feb 8, 2016
AI in cancer detectionComputer Science17 references4 citations
TL;DR

This paper proposes a semi-automated method for estimating tumor regions of interest (ROI) in ultrasound B-mode images of locally advanced breast cancer (LABC) patients using Radon barcodes. By leveraging content-based barcodes derived from global and local Radon transforms, the method identifies similar cases in a database to estimate a bounding box around the tumor, achieving 81% accuracy in leave-one-out validation, significantly reducing manual segmentation effort.

ABSTRACT

Quantitative ultrasound (QUS) methods provide a promising framework that can non-invasively and inexpensively be used to predict or assess the tumour response to cancer treatment. The first step in using the QUS methods is to select a region of interest (ROI) inside the tumour in ultrasound images. Manual segmentation, however, is very time consuming and tedious. In this paper, a semi-automated approach will be proposed to roughly localize an ROI for a tumour in ultrasound images of patients with locally advanced breast cancer (LABC). Content-based barcodes, a recently introduced binary descriptor based on Radon transform, were used in order to find similar cases and estimate a bounding box surrounding the tumour. Experiments with 33 B-scan images resulted in promising results with an accuracy of $81\%$.

Motivation & Objective

  • To address the time-consuming and tedious manual segmentation of tumor regions of interest (ROI) in ultrasound B-mode images of locally advanced breast cancer (LABC) patients.
  • To develop a fast, semi-automated approach for rough tumor localization that avoids full contour extraction, which is challenging due to low contrast and ambiguous tumor borders.
  • To evaluate the feasibility of using Radon barcodes as content-based image descriptors for ROI estimation in ultrasound imaging.
  • To enable efficient preprocessing for subsequent quantitative ultrasound (QUS) analysis, such as tissue characterization and treatment response prediction.
  • To reduce reliance on expert manual contouring, which can take days for large studies, especially in 3D ABUS imaging.

Proposed method

  • The method uses content-based Radon barcodes—binary descriptors derived from the Radon transform—to represent both global image content and local tumor ROI regions.
  • For each ground-truth image, two barcodes are generated: a global barcode for the full image and a local barcode for the tumor bounding box.
  • A query image is processed by user-provided center point click to define a fixed-size ROI, which is then used to extract its own global and local barcodes.
  • Similarity between the query and training images is computed using Hamming distance on both global and local barcodes, combined into a total dissimilarity score.
  • The top M most similar training cases are selected, and their bounding box coordinates are weighted by inverse similarity (using Eq. 5) to compute a fused estimated ROI (Eq. 4).
  • The final estimated ROI is evaluated using the Dice coefficient against the ground-truth bounding box to measure accuracy.

Experimental results

Research questions

  • RQ1Can Radon barcodes effectively represent tumor appearance in ultrasound images for content-based retrieval in the context of tumor ROI estimation?
  • RQ2How accurately can a semi-automated method using Radon barcodes estimate tumor bounding boxes compared to expert-annotated ground truth in low-contrast, noisy ultrasound images?
  • RQ3To what extent does user input (center point click) affect the accuracy of the estimated ROI, and how robust is the method to small variations in input location?
  • RQ4Can this approach significantly reduce the time and effort required for ROI selection in QUS-based cancer response monitoring and prediction studies?
  • RQ5Is the combination of global and local Radon barcodes more effective than using either alone for tumor localization in ultrasound imaging?

Key findings

  • The proposed method achieved a mean Dice similarity coefficient of 81% ± 14% in leave-one-out validation across 33 B-scan images from LABC patients.
  • The method demonstrated robustness to small variations in the user-provided center point, as long as it was within the vicinity of the true tumor center.
  • The use of both global and local Radon barcodes improved localization accuracy compared to using either descriptor alone, as confirmed by the combined similarity metric.
  • The approach significantly reduces manual effort in ROI selection—potentially cutting days of work in large-scale studies—by providing a fast, semi-automated alternative to full manual segmentation.
  • The method is computationally efficient and scalable, as it relies on binary barcode comparison rather than complex image registration or deep learning inference.
  • The results suggest strong potential for integration into QUS pipelines for treatment prediction and tissue characterization in breast cancer.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.