Skip to main content
QUICK REVIEW

[Paper Review] $ u$-net: Deep Learning for Generalized Biventricular Cardiac Mass and Function Parameters

Hinrich B. Winther, Christian Hundt|arXiv (Cornell University)|Jun 14, 2017
Cardiac Imaging and DiagnosticsMedicine23 references14 citations
TL;DR

This paper introduces ν-net, a deep learning model for fully automated, high-accuracy segmentation of left and right ventricular endocardium and epicardium in cardiac MRI. Trained on 253 manually segmented cases and validated across four multicenter datasets (>1,000 cases), ν-net achieves state-of-the-art performance with intraclass correlation coefficients (ICC) of 98% (LV EF), 96% (RV EF), and 95% (LV VM), demonstrating robust generalization and a simple adaptation procedure for varying segmentation philosophies.

ABSTRACT

Background: Cardiac MRI derived biventricular mass and function parameters, such as end-systolic volume (ESV), end-diastolic volume (EDV), ejection fraction (EF), stroke volume (SV), and ventricular mass (VM) are clinically well established. Image segmentation can be challenging and time-consuming, due to the complex anatomy of the human heart. Objectives: This study introduces $ u$-net (/nju:n$\varepsilon$t/) -- a deep learning approach allowing for fully-automated high quality segmentation of right (RV) and left ventricular (LV) endocardium and epicardium for extraction of cardiac function parameters. Methods: A set consisting of 253 manually segmented cases has been used to train a deep neural network. Subsequently, the network has been evaluated on 4 different multicenter data sets with a total of over 1000 cases. Results: For LV EF the intraclass correlation coefficient (ICC) is 98, 95, and 80 % (95 %), and for RV EF 96, and 87 % (80 %) on the respective data sets (human expert ICCs reported in parenthesis). The LV VM ICC is 95, and 94 % (84 %), and the RV VM ICC is 83, and 83 % (54 %). This study proposes a simple adjustment procedure, allowing for the adaptation to distinct segmentation philosophies. $ u$-net exhibits state of-the-art performance in terms of dice coefficient. Conclusions: Biventricular mass and function parameters can be determined reliably in high quality by applying a deep neural network for cardiac MRI segmentation, especially in the anatomically complex right ventricle. Adaption to individual segmentation styles by applying a simple adjustment procedure is viable, allowing for the processing of novel data without time-consuming additional training.

Motivation & Objective

  • To develop a deep learning model for fully automated, high-quality segmentation of biventricial endocardium and epicardium in cardiac MRI.
  • To improve generalization across diverse imaging protocols, acquisition techniques, and patient pathologies such as cardiomyopathies.
  • To enable adaptation to different segmentation philosophies—especially regarding trabeculations and papillary muscles—without retraining.
  • To deliver clinically accurate biventricular function and mass parameters (EF, ESV, EDV, SV, VM) with minimal human intervention.
  • To provide a scalable solution for large-scale, multicenter cardiac MRI analysis, reducing time and cost.

Proposed method

  • A deep neural network (U-Net based) was trained on 253 manually segmented cardiac MRI cases from a single center.
  • Non-linear data augmentation techniques were applied to artificially increase training data diversity and improve generalization.
  • The model was evaluated on four independent multicenter datasets totaling over 1,000 cases with varying acquisition protocols and pathologies.
  • Clinical parameters (EF, ESV, EDV, SV, VM) were computed from automated segmentations and compared to manual ground truth using ICC, Dice score, and Bland-Altman analysis.
  • A simple post-processing adjustment procedure was introduced to align predictions with specific segmentation philosophies (e.g., inclusion/exclusion of trabeculations).
  • The model uses the Simpson's method for volume calculation and applies a fixed density factor (1.05 g/cm³) to compute ventricular mass.

Experimental results

Research questions

  • RQ1Can a deep learning model achieve high-accuracy, fully automated segmentation of both left and right ventricular endocardium and epicardium across diverse cardiac MRI datasets?
  • RQ2How well does the model generalize across different imaging protocols, scanner manufacturers, and patient pathologies such as cardiomyopathy?
  • RQ3Can the model be adapted to different segmentation philosophies—particularly regarding trabeculations and papillary muscles—without retraining?
  • RQ4What is the performance of the model in estimating key clinical parameters (EF, ESV, EDV, SV, VM) compared to expert manual segmentation?
  • RQ5Can the model maintain high accuracy across multicenter, multi-reader settings without requiring extensive retraining?

Key findings

  • ν-net achieved an intraclass correlation coefficient (ICC) of 98% for left ventricular ejection fraction (LV EF) and 96% for right ventricular ejection fraction (RV EF) on independent multicenter datasets.
  • The model achieved ICCs of 95% for LV ventricular mass (VM) and 83% for RV VM, demonstrating strong reliability in mass estimation.
  • Dice similarity coefficients (DSC) for LV endocardial, myocardial, and epicardial segmentation were 91.5±4.3%, 88.8±2.9%, and 94.5±2.0%, respectively.
  • For the RV, DSC values were 87.7±5.5% (endocardial), 75.8±5.9% (myocardial), and 89.8±3.8% (epicardial), indicating high performance even in the complex right ventricle.
  • The proposed adjustment procedure enabled accurate adaptation to different segmentation philosophies without retraining, preserving high performance.
  • Correlation analysis showed high R² values (rho = 0.9762 for LV endocardial volume and 0.9598 for LV mass) on the MICCAI 2009 LVSC dataset, with low RMSD and MAPE.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.