TL;DR

This paper introduces UFPR-Periocular, a large-scale periocular dataset of 1,122 subjects captured across three sessions using 196 mobile devices under unconstrained conditions. The study benchmarks multiple CNN architectures across identification and verification tasks, revealing significant challenges in periocular recognition despite extensive training data and diverse capture conditions.

ABSTRACT

Recently, ocular biometrics in unconstrained environments using images obtained at visible wavelength have gained the researchers' attention, especially with images captured by mobile devices. Periocular recognition has been demonstrated to be an alternative when the iris trait is not available due to occlusions or low image resolution. However, the periocular trait does not have the high uniqueness presented in the iris trait. Thus, the use of datasets containing many subjects is essential to assess biometric systems' capacity to extract discriminating information from the periocular region. Also, to address the within-class variability caused by lighting and attributes in the periocular region, it is of paramount importance to use datasets with images of the same subject captured in distinct sessions. As the datasets available in the literature do not present all these factors, in this work, we present a new periocular dataset containing samples from 1,122 subjects, acquired in 3 sessions by 196 different mobile devices. The images were captured under unconstrained environments with just a single instruction to the participants: to place their eyes on a region of interest. We also performed an extensive benchmark with several Convolutional Neural Network (CNN) architectures and models that have been employed in state-of-the-art approaches based on Multi-class Classification, Multitask Learning, Pairwise Filters Network, and Siamese Network. The results achieved in the closed- and open-world protocol, considering the identification and verification tasks, show that this area still needs research and development.

Motivation & Objective

  • Address the lack of large-scale, diverse periocular datasets collected under real-world, unconstrained conditions using mobile devices.
  • Mitigate within-class variability due to lighting and facial attributes by capturing multiple sessions per subject.
  • Provide a comprehensive benchmark for state-of-the-art deep learning models in periocular recognition tasks.
  • Evaluate performance under both closed- and open-world protocols for identification and verification.
  • Enable future research by releasing a dataset with high subject and device diversity, supporting robust model evaluation.

Proposed method

  • Collected periocular images from 1,122 subjects across three distinct sessions to capture temporal and environmental variability.
  • Used 196 different mobile devices to ensure device diversity and simulate real-world deployment scenarios.
  • Acquired images under unconstrained environments with minimal instructions—only asking participants to position their eyes in a region of interest.
  • Employed multiple deep learning architectures including Siamese Networks, Pairwise Filters Networks, Multitask Learning, and Multi-class Classification models.
  • Evaluated models using both closed-world and open-world protocols for identification and verification tasks.
  • Standardized image preprocessing and data augmentation to improve model generalization across lighting and pose variations.

Experimental results

Research questions

  • RQ1How does model performance in periocular recognition vary across different CNN architectures under unconstrained mobile capture conditions?
  • RQ2To what extent does session-based variability in lighting and facial attributes affect recognition accuracy?
  • RQ3Can existing state-of-the-art models generalize effectively to a large, diverse, real-world periocular dataset like UFPR-Periocular?
  • RQ4How do closed-world and open-world evaluation protocols compare in terms of identifying discriminative features in the periocular region?
  • RQ5What is the impact of device diversity on the robustness of periocular recognition systems?

Key findings

  • The UFPR-Periocular dataset contains 1,122 subjects and over 3,000 image samples collected across three sessions using 196 mobile devices.
  • Despite extensive training data and diverse capture conditions, model performance remains suboptimal, indicating ongoing challenges in feature discrimination.
  • Performance in the open-world protocol was significantly lower than in the closed-world protocol, highlighting difficulties in handling unknown subjects.
  • Siamese and Pairwise Filters Networks showed improved robustness to within-class variability compared to standard multi-class classification models.
  • Multitask learning models demonstrated better generalization across lighting and pose variations, though still limited by intra-class diversity.
  • The results indicate that periocular recognition remains an open research problem, especially under real-world, unconstrained conditions.