[Paper Review] Uncertainty-aware deep learning for digital twin-driven monitoring: Application to fault detection in power lines
This paper proposes an uncertainty-aware deep learning framework for digital twin-driven fault detection in power lines, combining assumed density filtering (ADF) for aleatoric uncertainty and Monte Carlo dropout for epistemic uncertainty. Results show that probabilistic models significantly improve prediction confidence and classification accuracy over deterministic models, with ADF-based models achieving the best performance and generalization.
Deep neural networks (DNNs) are often coupled with physics-based models or data-driven surrogate models to perform fault detection and health monitoring of systems in the low data regime. These models serve as digital twins to generate large quantities of data to train DNNs which would otherwise be difficult to obtain from the real-life system. However, such models can exhibit parametric uncertainty that propagates to the generated data. In addition, DNNs exhibit uncertainty in the parameters learnt during training. In such a scenario, the performance of the DNN model will be influenced by the uncertainty in the physics-based model as well as the parameters of the DNN. In this article, we quantify the impact of both these sources of uncertainty on the performance of the DNN. We perform explicit propagation of uncertainty in input data through all layers of the DNN, as well as implicit prediction of output uncertainty to capture the former. Furthermore, we adopt Monte Carlo dropout to capture uncertainty in DNN parameters. We demonstrate the approach for fault detection of power lines with a physics-based model, two types of input data and three different neural network architectures. We compare the performance of such uncertainty-aware probabilistic models with their deterministic counterparts. The results show that the probabilistic models provide important information regarding the confidence of predictions, while also delivering an improvement in performance over deterministic models.
Motivation & Objective
- Address the challenge of unreliable DNN performance in low-data regimes when training on data generated by digital twins with inherent uncertainty.
- Quantify and mitigate the impact of two uncertainty sources: parametric uncertainty in digital twins and parameter uncertainty in trained DNNs.
- Develop a unified uncertainty quantification framework that enhances model reliability for real-world deployment in power system monitoring.
- Evaluate the effectiveness of uncertainty-aware models compared to deterministic counterparts in fault detection for power lines.
Proposed method
- Use a physics-based digital twin to generate synthetic data for training DNNs, incorporating parametric uncertainty through multiple realizations.
- Apply assumed density filtering (ADF) to explicitly model heteroscedastic aleatoric uncertainty by estimating input-dependent variance.
- Employ Monte Carlo dropout to quantify epistemic uncertainty by sampling from the posterior distribution of DNN weights during inference.
- Train and evaluate three DNN architectures (Plain, Heteroscedastic, ADF) on both synthetic and real-like data to compare uncertainty-aware and deterministic models.
- Fuse data from 10 digital twin instances to improve input statistics and assess the impact on model performance and uncertainty estimation.
- Use variance-aware loss functions and evaluate model performance using metrics like AUC-ROC and prediction confidence intervals.
Experimental results
Research questions
- RQ1How does uncertainty in digital twin-generated data affect the performance and reliability of DNN-based fault detection models?
- RQ2To what extent can assumed density filtering (ADF) and Monte Carlo dropout improve prediction confidence and generalization in low-data scenarios?
- RQ3How does information fusion from multiple digital twin instances influence the performance of uncertainty-aware DNN models?
- RQ4Can ADF-based models maintain high performance when deployed with fixed variance estimates instead of dynamic input variance?
- RQ5What is the comparative performance of deterministic, heteroscedastic, and ADF-based models in classifying healthy vs. faulty power line conditions?
Key findings
- Probabilistic models, particularly those using assumed density filtering (ADF), significantly outperform deterministic models in fault detection accuracy and generalization.
- ADF-based models achieve the highest classification performance, with a marginal drop of only ~2% in performance when using a fixed variance of 0.53 instead of dynamic variance estimation.
- Heteroscedastic models perform poorly in this case study, despite their theoretical elegance in predicting input-dependent aleatoric uncertainty.
- Fusing data from 10 digital twin instances enables Plain and Heteroscedastic models to achieve performance comparable to ADF models, highlighting the value of data diversity.
- The prediction variance in ADF models clearly distinguishes between healthy and faulty conditions, providing valuable interpretability for decision-making.
- Even with reduced variance information, ADF models retain a meaningful distinction between healthy and faulty data, indicating robustness to partial uncertainty estimation.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.