Skip to main content
QUICK REVIEW

[Paper Review] Unsupervised MR Motion Artifact Deep Learning using Outlier-Rejecting Bootstrap Aggregation

Gyutaek Oh, Jeong Eun Lee|arXiv (Cornell University)|Nov 12, 2020
Advanced MRI Techniques and ApplicationsMedicine44 references6 citations
TL;DR

This paper proposes an unsupervised deep learning method for MR motion artifact correction that uses outlier-rejecting bootstrap aggregation via k-space subsampling along the phase encoding direction to suppress motion-induced k-space outliers. By training a cycle-GAN with optimal transport-driven unsupervised learning, the method achieves high-quality artifact removal without paired training data, outperforming state-of-the-art methods in both quantitative metrics and clinical evaluation on simulated and real transient severe motion (TSM) data.

ABSTRACT

Recently, deep learning approaches for MR motion artifact correction have been extensively studied. Although these approaches have shown high performance and reduced computational complexity compared to classical methods, most of them require supervised training using paired artifact-free and artifact-corrupted images, which may prohibit its use in many important clinical applications. For example, transient severe motion (TSM) due to acute transient dyspnea in Gd-EOB-DTPA-enhanced MR is difficult to control and model for paired data generation. To address this issue, here we propose a novel unsupervised deep learning scheme through outlier-rejecting bootstrap subsampling and aggregation. This is inspired by the observation that motions usually cause sparse k-space outliers in the phase encoding direction, so k-space subsampling along the phase encoding direction can remove some outliers and the aggregation step can further improve the results from the reconstruction network. Our method does not require any paired data because the training step only requires artifact-free images. Furthermore, to address the smoothing from potential bias to the artifact-free images, the network is trained in an unsupervised manner using optimal transport driven cycleGAN. We verify that our method can be applied for artifact correction from simulated motion as well as real motion from TSM successfully, outperforming existing state-of-the-art deep learning methods.

Motivation & Objective

  • To address the lack of paired motion-free and artifact-corrupted MR images in clinical settings, especially for transient severe motion (TSM) in Gd-EOB-DTPA-enhanced MRI.
  • To develop a deep learning method that corrects motion artifacts without requiring supervised paired data, which is often unavailable in real-world clinical applications.
  • To improve image quality by explicitly rejecting k-space outliers caused by motion, leveraging the sparsity of motion-induced phase-encoding artifacts.
  • To reduce blurring and preserve anatomical details by using optimal transport-driven cycle-GAN instead of standard supervised training.

Proposed method

  • The method uses k-space subsampling along the phase encoding direction to probabilistically reject motion-induced outliers, exploiting their sparsity in k-space.
  • Bootstrap aggregation is applied by training a reconstruction network on multiple random k-space subsampling masks to improve robustness.
  • An unsupervised cycle-GAN framework is employed with optimal transport to align domain distributions between artifact and clean images, avoiding bias from paired data.
  • The network is trained solely on artifact-free MR images, eliminating the need for paired data during training.
  • The framework is designed to be robust to real-world motion artifacts, including TSM in hepatobiliary phase MRI.
  • The method integrates k-space subsampling with deep learning reconstruction to achieve artifact correction without explicit motion modeling.

Experimental results

Research questions

  • RQ1Can k-space subsampling along the phase encoding direction effectively reject motion-induced outliers in MR images?
  • RQ2Does unsupervised training with optimal transport-driven cycle-GAN outperform supervised learning in preserving image details and reducing blurring?
  • RQ3Can the proposed method achieve high-quality motion artifact correction without any paired training data?
  • RQ4How does the method perform on real transient severe motion (TSM) data compared to existing state-of-the-art methods?
  • RQ5Is the performance of the method sensitive to subsampling direction, and does phase encoding direction subsampling uniquely enable artifact correction?

Key findings

  • The method successfully corrects both simulated and real motion artifacts in TSM-affected Gd-EOB-DTPA-enhanced MR scans without requiring paired data.
  • Subsampling along the phase encoding direction is essential for artifact correction; frequency encoding direction subsampling fails to remove motion artifacts.
  • The unsupervised cycle-GAN with optimal transport preserves fine anatomical textures better than supervised training, which leads to blurring.
  • The method achieves competitive quantitative metrics compared to the supervised state-of-the-art method MARC, despite not using paired data.
  • Clinical evaluation confirms that the method produces diagnostically usable images with improved structural fidelity and reduced artifacts.
  • The method outperforms Cycle-MedGAN V2.0 in both quantitative metrics and qualitative results, avoiding the amplification of residual artifacts.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.