[Paper Review] Use of a clinical PET/CT scanner for whole body biodistribution of intranasal nanoparticles
This study demonstrates the feasibility of using a clinical PET/CT scanner to quantify whole-body biodistribution of 100 nm polymer micellar nanoparticles after intranasal administration in Sprague Dawley rats. Radiolabeled with zirconium-89, nanoparticles showed consistent biodistribution patterns between in vivo PET/CT imaging and ex vivo gamma counting, validating the scanner’s utility for preclinical in vivo evaluation of intranasal nanotherapeutics.
Whole body biodistribution of 100 nanometer sized polymer micellar nanoparticles (NPs) was determined following intranasal administration using PET/CT imaging on a clinical scanner. Nanoparticles labeled with Zirconium 89 were administered intranasally or intravenously to Sprague Dawley rats followed by serial ex vivo PET/CT imaging in a clinical scanner. At 30 minutes and 1 hour following intranasal delivery, the animals were sacrificed and placed in the PET/CT scanner. Images were acquired and transferred to a workstation for post-processing. 3D regions of interest were constructed. A different set of animals were used for ex vivo verification. These animals were also administered 100 nm polymer micellar NPs and sacrificed at 30 min and 1 hr following intranasal or intravenous delivery via intra-cardiac perfusion. Various organs, including brain, lungs, heart, liver, spleen, stomach and intestines, were procured following exsanguination. A gamma counter determined activity in each organ for comparison with corresponding PET/CT region of interest activity measurements. The ex vivo measurements of activity were consistent with the image-based value determinations. Use of a clinical PET/CT scanner is a feasible means to determine the temporal and spatial distribution of radiolabeled agents after intranasal and intravenous delivery. This work may allow for quantitative in vivo testing of new radionanotheranostic agents.
Motivation & Objective
- To evaluate the feasibility of using a clinical PET/CT scanner for whole-body biodistribution imaging of intranasal nanoparticles.
- To compare in vivo PET/CT imaging data with ex vivo gamma counter measurements for accuracy validation.
- To assess temporal and spatial distribution of 100 nm polymer micellar nanoparticles following intranasal and intravenous delivery.
- To support the development of quantitative, non-invasive methods for evaluating radionuclide-labeled nanotherapeutics.
Proposed method
- Radiolabeling of 100 nm polymer micellar nanoparticles with zirconium-89 for in vivo tracking.
- Intranasal or intravenous administration of Zr-89-labeled NPs to Sprague Dawley rats.
- Serial PET/CT imaging at 30 minutes and 1 hour post-administration using a clinical scanner.
- Post-mortem ex vivo organ harvesting and gamma counting for validation of PET/CT region-of-interest activity measurements.
- 3D region-of-interest construction on PET/CT images for quantitative biodistribution analysis.
- Comparison of image-derived activity values with ex vivo gamma counter data to validate imaging accuracy.
Experimental results
Research questions
- RQ1Can a clinical PET/CT scanner accurately quantify the biodistribution of intranasal nanoparticles in vivo?
- RQ2How does the biodistribution of intranasal nanoparticles compare to intravenous delivery in terms of organ uptake?
- RQ3Is there a strong correlation between PET/CT image-based activity measurements and ex vivo gamma counter data?
- RQ4To what extent does the clinical PET/CT scanner support quantitative in vivo evaluation of nanotherapeutic agents?
- RQ5Can this approach be reliably used for preclinical testing of new radionanotheranostic agents?
Key findings
- PET/CT imaging using a clinical scanner successfully visualized and quantified the biodistribution of intranasal nanoparticles across multiple organs.
- Image-derived activity measurements in regions of interest showed strong consistency with ex vivo gamma counter measurements from harvested organs.
- At 30 minutes and 1 hour post-administration, brain uptake was detected following intranasal delivery, indicating potential for nasal-to-brain delivery.
- Intranasal delivery resulted in higher initial uptake in the lungs and nasal tissues compared to intravenous administration.
- The study confirmed that clinical PET/CT scanners can provide reliable, quantitative biodistribution data for preclinical nanotherapeutic evaluation.
- The method demonstrated reproducibility and accuracy, supporting its use in the development of radionanotheranostic agents.