[Paper Review] Voltage control of DC networks: robustness for unknown ZIP-loads

Michele Cucuzzella, Krishna Chaitanya Kosaraju|arXiv (Cornell University)|Jul 23, 2019
Microgrid Control and OptimizationEngineering43 references11 citations
TL;DR

This paper proposes a novel passivity-based control scheme for DC microgrids with unknown ZIP-loads (impedance, current, and power components), using a mixed potential function to establish passivity with the voltage derivative as the output port-variable. The method ensures robust voltage regulation under all positive voltage references and arbitrary load parameters, eliminating restrictive assumptions present in prior work.

ABSTRACT

In this paper we propose a new passivity-based control technique for DC power networks comprising the so-called ZIP-loads, i.e., nonlinear loads with the parallel combination of unknown constant impedance (Z), current (I) and power (P) components. More precisely, we propose a novel passifying input and a storage function based on the so-called mixed potential function introduced by Brayton and Moser, leading to a novel passivity property with output port-variable equal to the first time derivative of the voltage. Differently from the existing results in the literature, where restrictive (sufficient) conditions on Z, P and the voltage reference are assumed to be satisfied, we establish a passivity property for every positive voltage reference and every type of load. Consequently, we develop a new decentralized passivity-based control scheme that is robust with respect to the uncertainty affecting the ZIP-loads.

Motivation & Objective

  • Address the instability caused by constant power (P) loads in DC microgrids, which exhibit negative incremental impedance and can lead to voltage oscillations or collapse.
  • Overcome the limitations of existing passivity-based controllers that require restrictive sufficient conditions on Z, P, and voltage reference for passivity.
  • Develop a decentralized control scheme that is robust to uncertainties in ZIP-load parameters, including the absence of Z-components.
  • Enable voltage regulation toward desired references even when the equivalent conductance becomes negative due to high P-load contributions.
  • Establish a new passivity property where the output is the time derivative of voltage, enabling effective damping injection independent of load composition.

Proposed method

  • Introduce a novel passifying input that combines feedforward compensation for filter resistance and damping injection via modification of the system's dissipative structure.
  • Propose a storage function based on the mixed potential function from Brayton and Moser theory, ensuring the closed-loop system is passive with output equal to the voltage derivative.
  • Shape the storage function to have a minimum at the desired equilibrium point, ensuring asymptotic stability of the voltage reference.
  • Use a decentralized control architecture where each node independently computes its control input based on local measurements, enhancing scalability and robustness.
  • Establish passivity for all trajectories with positive voltage, under only a mild assumption (positive voltage reference), without requiring bounds on Z, P, or their ratios.
  • Demonstrate that the controller remains effective even when traditional passivity properties (e.g., shifted or Krasovskii) fail due to negative equivalent conductance.

Experimental results

Research questions

  • RQ1Can a passivity-based control scheme be designed for DC networks with unknown ZIP-loads that remains effective even when the equivalent conductance becomes negative?
  • RQ2Is it possible to establish passivity with the voltage derivative as the output port-variable without restrictive assumptions on load parameters or voltage reference?
  • RQ3How can damping be effectively injected into a DC network with P-loads to counteract their negative incremental impedance?
  • RQ4Can a decentralized control strategy ensure voltage regulation toward desired references regardless of the presence or absence of Z-components in the loads?
  • RQ5What is the performance of the proposed controller under load parameter variations that invalidate standard passivity-based approaches?

Key findings

  • The proposed controller achieves robust voltage regulation for all positive voltage references and all combinations of ZIP-load parameters, including cases where the equivalent conductance is negative.
  • The closed-loop system is passive with output equal to the time derivative of voltage, enabling effective damping injection independent of load composition.
  • In Scenario 1 (mixed ZIP-loads), the controller maintains stability and regulation even when load parameters are changed such that the equivalent conductance becomes negative (e.g., from 0.011 S to -0.017 S at Node 1).
  • In Scenario 2 (pure P-loads), the controller successfully regulates voltages to their references without requiring any Z-component, demonstrating robustness beyond the scope of prior methods.
  • The controller outperforms existing schemes (e.g., [17]) that become unstable under high P-load conditions, as confirmed by simulation results showing stable voltage convergence.
  • Theoretical analysis confirms that the passivity property holds for all trajectories with positive voltage, under only a mild assumption, making the approach widely applicable to real-world DC microgrids.