Skip to main content
QUICK REVIEW

[Paper Review] X-ray observations of the isolated black hole candidate OGLE-2011-BLG-0462 , and other collapsed objects discovered through gravitational microlensing

S. Mereghetti, L. Sidoli|arXiv (Cornell University)|Jun 15, 2022
Astrophysical Phenomena and ObservationsPhysics and Astronomy37 references9 citations
TL;DR

This study presents the first X-ray upper limits for the isolated black hole candidate OGLE-2011-BLG-0462, using Chandra, XMM-Newton, and INTEGRAL data. It finds that the observed X-ray flux is consistent with low-efficiency accretion expected for a black hole, disfavoring a neutron star interpretation despite ongoing debate over its mass and nature.

ABSTRACT

Isolated black holes and neutron stars can be revealed through the observation of long duration gravitational microlensing events. A few candidates have been found in surveys of stars in the direction of the Galactic bulge. Recently, thanks to the addition of astrometric information at milliarcsecond level, it has been possible to reduce the uncertainties in the masses and distances for some of these "dark" gravitational lenses and select the most promising candidates. These isolated compact objects might emit X-rays powered by accretion from the interstellar medium. Using data of the Chandra, XMM-Newton, and INTEGRAL satellites, we searched for X-ray emission in the isolated black hole candidate OGLE-2011-BLG-0462, and in several other putative collapsed objects found with gravitational microlensing. OGLE-2011-BLG-0462 has been recently interpreted as a 7.1 M_sun black hole at a distance of 1.6 kpc, although a different group obtained a mass range (1.6-4.4 M_sun) that cannot exclude a massive neutron star. We have derived upper limits on the flux from OGLE-2011-BLG-0462 of 9$ imes10^{-15}$ erg cm$^{-2}$ s$^{-1}$ in the 0.5-7 keV range and $\sim2 imes10^{-12}$ erg cm$^{-2}$ s$^{-1}$ in the 17-60 keV range. The implied X-ray luminosity is consistent with the small radiative efficiency expected for a black hole and disfavours a neutron star interpretation. Limits down to a factor about five lower are obtained for the soft X-ray flux of other candidates, but their interpretation is affected by larger uncertainties in the masses, distances and spatial velocities.

Motivation & Objective

  • To test the hypothesis that isolated stellar-mass black holes and neutron stars can be detected via X-ray emission from interstellar medium accretion.
  • To resolve the ambiguity in the nature of OGLE-2011-BLG-0462—whether it is a 7.1 M⊙ black hole or a massive neutron star—using X-ray observations.
  • To establish the tightest existing X-ray flux upper limits for microlensing-derived compact object candidates, especially OGLE-2011-BLG-0462.
  • To assess the impact of uncertain space velocities and distances on accretion rate estimates for isolated compact objects.
  • To enable future statistical studies of ISM accretion by compiling high-sensitivity X-ray limits for a sample of microlensed compact objects.

Proposed method

  • Acquired and analyzed archival X-ray data from Chandra, XMM-Newton, and INTEGRAL for the microlensing event OGLE-2011-BLG-0462 and other candidate collapsed objects.
  • Calculated soft X-ray flux upper limits in the 0.5–7 keV band (9×10⁻¹⁵ erg cm⁻² s⁻¹) and hard X-ray limits in the 17–60 keV band (∼2×10⁻¹² erg cm⁻² s⁻¹) for OGLE-2011-BLG-0462.
  • Used the Bondi accretion model to estimate expected X-ray luminosities based on mass, radius, and velocity for both black hole and neutron star scenarios.
  • Projected X-ray flux limits onto the ISM density–space velocity plane to constrain the environment of each candidate, assuming MNS = 1.4 M⊙, RNS = 10 km, and λ = 1.
  • Combined soft and hard X-ray limits to assess the robustness of constraints under varying interstellar absorption conditions.
  • Applied statistical modeling to account for uncertainties in lens mass, distance, and transverse velocity, particularly for the neutron star interpretation of OGLE-2011-BLG-0462.

Experimental results

Research questions

  • RQ1Is the isolated compact object OGLE-2011-BLG-0462 consistent with a black hole or a neutron star based on X-ray non-detection?
  • RQ2What are the tightest current X-ray flux upper limits for microlensed compact object candidates, especially OGLE-2011-BLG-0462?
  • RQ3How do uncertainties in space velocity and distance affect the inferred accretion rates and X-ray luminosities of isolated compact objects?
  • RQ4Can X-ray observations distinguish between black hole and neutron star candidates in the absence of optical or radio counterparts?
  • RQ5What constraints do X-ray limits place on the local interstellar medium density around isolated compact objects?

Key findings

  • The soft X-ray flux upper limit for OGLE-2011-BLG-0462 is 9×10⁻¹⁵ erg cm⁻² s⁻¹ in the 0.5–7 keV band, consistent with low-efficiency accretion expected for a black hole.
  • The hard X-ray flux upper limit in the 17–60 keV band is ∼2×10⁻¹² erg cm⁻² s⁻¹, providing absorption-independent constraints applicable even in dense molecular environments.
  • The X-ray flux limits disfavor a neutron star interpretation for OGLE-2011-BLG-0462, as the expected flux for a neutron star with typical space velocity exceeds the observed upper limit unless in a very low-density environment.
  • For OGLE-2011-BLG-0462, a space velocity below 100 km s⁻¹ implies an ISM density below ∼10 cm⁻³, excluding it from being inside or within a dense molecular cloud.
  • The study provides the tightest X-ray flux upper limits to date for microlensing-derived compact object candidates, with limits down to a factor of five lower than previous estimates for soft X-rays.
  • The relative positions of flux limits in the velocity–density plane are primarily determined by the space velocity of the source, highlighting the critical role of velocity uncertainty in accretion modeling.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.