Skip to main content
QUICK REVIEW

[Paper Review] XENON1T implications for the DAMA annual modulation: The good, the bad and the ugly

R. Foot|arXiv (Cornell University)|Nov 5, 2020
Dark Matter and Cosmic PhenomenaPhysics and Astronomy4 citations
TL;DR

This paper re-evaluates a mirror dark matter model with collisional shielding that explains the DAMA annual modulation via low-energy electron recoils. It finds that while the model can simultaneously fit the DAMA signal and the XENON1T electron recoil excess, a severe tension arises with the XENON1T S2-only analysis, which rules out the predicted rate at ~1 keV, challenging the model's viability unless the analysis contains flaws.

ABSTRACT

Previous work has argued that the DAMA annual modulation signal might be due to electron recoils in plasma dark matter models. A specific model assuming mirror dark matter and featuring collisional shielding of a detector due to Earth-bound dark matter was put forward by this author [arXiv:1806.04293]. That explanation predicted a low energy electron recoil signal in the XENON1T experiment. In light of the excess of electron recoils observed in XENON1T, we re-examine that model's predictions for both DAMA and XENON1T.

Motivation & Objective

  • To assess the viability of a mirror dark matter model with collisional shielding in explaining the DAMA annual modulation signal.
  • To examine whether the same model can simultaneously account for the low-energy electron recoil excess observed in XENON1T.
  • To evaluate the consistency of the model with recent constraints, particularly from the XENON1T S2-only analysis.
  • To investigate the impact of energy scale uncertainties on the spectral shape of the predicted recoil rate.
  • To determine whether the model remains viable in light of conflicting constraints from LUX and XENON1T.

Proposed method

  • The model employs mirror dark matter with kinetic mixing-induced Coulomb interactions between dark electrons and ordinary electrons.
  • It incorporates collisional shielding of the detector by Earth-bound dark matter, which modifies the energy spectrum of incoming dark electrons.
  • The interaction rate is modeled as dR/dER ∝ 1/ER² for ER ≲ ET, with a spectral knee at ET, dependent on model parameters.
  • The analysis uses a benchmark point with ET ≈ 1.7 keV from a prior study (shield1) to test consistency with DAMA and XENON1T data.
  • The model's predictions are compared with DAMA's annual modulation data, XENON1T's low-energy excess, and the S2-only analysis from XENON1T.
  • Energy scale mismodelling is explored as a potential mechanism to flatten the steep spectral shape to match DAMA observations.

Experimental results

Research questions

  • RQ1Can the mirror dark matter model with collisional shielding simultaneously explain the DAMA annual modulation and the XENON1T electron recoil excess?
  • RQ2How sensitive is the model's predicted recoil spectrum to energy scale uncertainties in the experiments?
  • RQ3To what extent is the model ruled out by the XENON1T S2-only analysis, which sets a stringent upper limit on electron recoils at ~1 keV?
  • RQ4Why does the LUX experiment fail to observe a similar excess, and could location-dependent shielding effects explain the discrepancy?
  • RQ5Is the observed tension between the model and XENON1T S2-only data due to a flaw in the analysis or a fundamental flaw in the model?

Key findings

  • The model can simultaneously explain the DAMA annual modulation and the XENON1T electron recoil excess, though with a significant tension in spectral shape.
  • The predicted recoil spectrum is too steep to match DAMA data unless energy scale uncertainties of ~0.6 keV are introduced to flatten it.
  • The XENON1T S2-only analysis places a stringent limit of dR/dER ≤ 1 event/tonne/day/keV at ER ~ 1 keV, which is incompatible with the model’s prediction.
  • The LUX experiment’s constraints on electron recoil modulation are strong, but the model may still be viable if shielding effects depend on location, such as elevation or terrain.
  • The model’s prediction for the XENON1T excess is consistent with the observed rate, but only if the spectral knee ET is above ~4 keV or the excess is not due to the same physics as the DAMA signal.
  • The incompatibility with the S2-only analysis poses a major challenge, suggesting the model is unlikely unless that analysis contains a fundamental flaw.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.