Skip to main content
QUICK REVIEW

[Paper Review] Y-Net: A deep Convolutional Neural Network for Polyp Detection

Ahmed Mohammed, Sule Yildirim Yayilgan|arXiv (Cornell University)|Jan 1, 2018
Colorectal Cancer Screening and DetectionMedicine11 references35 citations
TL;DR

This paper proposes Y-Net, a novel two-encoder, one-decoder U-Net-inspired deep learning architecture for polyp detection in colonoscopy videos. It combines a pre-trained VGG19 encoder with a randomly initialized mirrored encoder, using a novel sum-skip-concatenation operation and encoder-specific learning rates to improve feature learning from limited medical data. Y-Net achieves 85.9% F1-score and 84.4% recall on the ASU-MAYO dataset, outperforming state-of-the-art methods by 7.3% in F1-score and 13% in recall.

ABSTRACT

Colorectal polyps are important precursors to colon cancer, the third most common cause of cancer mortality for both men and women. It is a disease where early detection is of crucial importance. Colonoscopy is commonly used for early detection of cancer and precancerous pathology. It is a demanding procedure requiring significant amount of time from specialized physicians and nurses, in addition to a significant miss-rates of polyps by specialists. Automated polyp detection in colonoscopy videos has been demonstrated to be a promising way to handle this problem. {However, polyps detection is a challenging problem due to the availability of limited amount of training data and large appearance variations of polyps. To handle this problem, we propose a novel deep learning method Y-Net that consists of two encoder networks with a decoder network. Our proposed Y-Net method} relies on efficient use of pre-trained and un-trained models with novel sum-skip-concatenation operations. Each of the encoders are trained with encoder specific learning rate along the decoder. Compared with the previous methods employing hand-crafted features or 2-D/3-D convolutional neural network, our approach outperforms state-of-the-art methods for polyp detection with 7.3% F1-score and 13% recall improvement.

Motivation & Objective

  • To address the challenge of low polyp detection accuracy in colonoscopy due to limited annotated training data and high appearance variation.
  • To improve detection performance in polyp detection by leveraging both pre-trained and untrained encoder networks.
  • To reduce false positives and false negatives in polyp detection by introducing a novel sum-skip-concatenation mechanism for feature fusion.
  • To achieve high recall and precision in polyp detection without relying on extensive data augmentation.
  • To develop a practical deep learning framework that generalizes well across diverse polyp shapes, sizes, and textures in real colonoscopy videos.

Proposed method

  • Y-Net employs a dual-encoder, single-decoder architecture inspired by U-Net, where one encoder is a pre-trained VGG19 and the other is a randomly initialized mirrored network.
  • The model uses a novel sum-skip-concatenation operation to fuse features from both encoders before passing them to the decoder, enabling deeper and more robust feature learning.
  • Encoder-specific learning rates are applied during training: the pre-trained encoder is fine-tuned with a lower rate, while the untrained encoder is trained from scratch with a higher rate.
  • The decoder is trained from scratch using a discriminative loss function to optimize for polyp localization and segmentation.
  • The framework avoids extensive data augmentation, relying instead on architectural innovation to generalize from limited training data.
  • The model is trained end-to-end on the ASU-MAYO polyp detection dataset, with inference performed on test videos to evaluate detection latency and segmentation accuracy.

Experimental results

Research questions

  • RQ1Can a dual-encoder architecture combining pre-trained and untrained networks improve polyp detection performance on limited medical datasets?
  • RQ2Does the proposed sum-skip-concatenation operation enhance feature representation and segmentation accuracy compared to standard skip connections?
  • RQ3How does encoder-specific learning rate scheduling affect model convergence and performance in polyp detection?
  • RQ4Can Y-Net achieve higher recall and F1-score than state-of-the-art methods without relying on data augmentation?
  • RQ5What is the detection latency of Y-Net in real-time colonoscopy video sequences?

Key findings

  • Y-Net achieves a 85.9% F1-score on the ASU-MAYO dataset, representing a 7.3% improvement over the previous state-of-the-art method.
  • The model records 84.4% recall, a 13% improvement over the prior state-of-the-art, indicating significantly better detection of true polyp instances.
  • Y-Net achieves the highest number of true positives (3582) and the lowest number of false negatives (662) among all compared methods on the ASU-MAYO dataset.
  • The model demonstrates a detection latency of 8 frames or less for all polyp-containing test videos, indicating real-time applicability.
  • The use of a pre-trained VGG19 encoder combined with a randomly initialized mirrored encoder and sum-skip-concatenation outperforms both single-encoder U-Net variants and hybrid hand-crafted feature methods.
  • The ablation study confirms that the fusion of pre-trained and untrained encoders yields the best balance between precision and recall, outperforming models with only a pre-trained encoder or a randomly initialized encoder.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.