Skip to main content

Eun Seok Cho

Yonsei University · 医学

研究室紹介

Professor Eun Seok Cho's research lab specializes in medical imaging and image-guided interventions, with a focus on optimizing diagnostic accuracy and image quality in abdominal and biliary tract imaging. The lab investigates advanced computed tomography (CT) protocols—particularly low-kVp techniques with various iodinated contrast media—to enhance vascular contrast, reduce radiation dose, and improve diagnostic performance in hepatocellular carcinoma and cholangiocarcinoma. Additionally, the lab explores magnetic resonance imaging (MRI) biomarkers for predicting HCC prognosis, emphasizing quantitative imaging features such as apparent diffusion coefficient (ADC) values and hepatobiliary phase enhancement. The integration of advanced imaging techniques with clinical outcomes defines the lab’s translational research approach.

low-kVp CTiodine contrastMRI biomarkersliver cancer imagingimage optimization

Research Overview

Papers
110
Total Citations
1,632
Papers (5y)
25
Primary Field
医学

Research Output Trend

Figures are computed from collected data and may differ slightly.

Publications per year (5y)
25total
2021
2022
2023
2024
2025
Citations per year (5y)
477total
20212022202320242025

Selected Papers

15
1
Article|126 citations·2020
Gadoxetic acid-enhanced MRI of macrotrabecular-massive hepatocellular carcinoma and its prognostic implications
Hyungjin Rhee, Eun‐Suk Cho, Ji Hae Nahm, Mi Jang, Yong Eun Chung, Song‐Ee Baek, Sunyoung Lee, Myeong‐Jin Kim, Mi‐Suk Park, Dai Hoon Han, Jin‐Young Choi, Young Nyun Park
SJR Q1Journal of Hepatology
HepatologyMedicine
2
Review|110 citations·2015
MRI Features of Hepatocellular Carcinoma Related to Biologic Behavior
Eun‐Suk Cho, Jin‐Young Choi
SJR Q1Korean Journal of RadiologyOA

Imaging studies including magnetic resonance imaging (MRI) play a crucial role in the diagnosis and staging of hepatocellular carcinoma (HCC). Several recent studies reveal a large number of MRI features related to the prognosis of HCC. In this review, we discuss various MRI features of HCC and their implications for the diagnosis and prognosis as imaging biomarkers. As a whole, the favorable MRI findings of HCC are small size, encapsulation, intralesional fat, high apparent diffusion coefficien

EpidemiologyMedicine
3
Article|67 citations·2021
Preoperative prediction of postsurgical outcomes in mass-forming intrahepatic cholangiocarcinoma based on clinical, radiologic, and radiomics features
Hyo Jung Park, Bumwoo Park, Seo Young Park, Sang Hyun Choi, Hyungjin Rhee, Ji Hoon Park, Eun-Suk Cho, Suk Keu Yeom, Sumi Park, Mi‐Suk Park, Seung Soo Lee
SJR Q1European RadiologyOA
SurgeryMedicine
4
Article|66 citations·2021
Impact of subcutaneous and visceral fat adiposity in patients with colorectal cancer
Jin‐Mok Kim, Eric Chung, Eun‐Suk Cho, Jae Hoon Lee, Su‐Jin Shin, Hye Sun Lee, Eun Jung Park, Seung Hyuk Baik, Kang Young Lee, Jeonghyun Kang
SJR Q1Clinical NutritionOA
PhysiologyMedicine
5
Article|56 citations·2011
Cerebral Computed Tomography Angiography Using a Low Tube Voltage (80 kVp) and a Moderate Concentration of Iodine Contrast Material
Eun‐Suk Cho, Tae‐Sub Chung, Dae Kun Oh, Hyun Seok Choi, Sang Hyun Suh, Hyeon-Kyeong Lee, Kyung Hee Lee
SJR Q1Investigative Radiology

The use of 80 kVp with MC-CM improved arterial enhancement, SNR, and CNR and provided superior quality images using a smaller amount of iodine and a lower radiation dose than the conventional protocol of 120 kVp with HC-CM.

Radiology, Nuclear Medicine and ImagingMedicine
6
Article|54 citations·2008
A Survey of Consistency Checking Techniques for UML Models
Muhammad Usman, Aamer Nadeem, Tai-hoon Kim, Eun‐Suk Cho

UML is the de-facto industry standard to design object-oriented software. UML provides a set of diagrams to model every aspect of an object-oriented application design in sufficient detail, but lacks any mechanism to rigorously check consistency between the models. Today, most of the effort is applied on creating accurate and consistent UML models rather than implementing the design. Automatic code generation from UML models has emerged as a promising area in recent years. The accuracy of genera

Artificial IntelligenceComputer Science
7
Article|52 citations·2004
Early Biliary Complications of Laparoscopic Cholecystectomy: Evaluation on T2-Weighted MR Cholangiography in Conjunction with Mangafodipir Trisodium-Enhanced T1-Weighted MR Cholangiography
Mi‐Suk Park, Ki Whang Kim, Jeong‐Sik Yu, Myeong‐Jin Kim, Kyoung Won Kim, Joon Seok Lim, Eun‐Suk Cho, Dong Sup Yoon, Tae Kyoung Kim, Sung In Lee, Jong Du Lee, Woo Jung Lee
SJR Q1American Journal of RoentgenologyOA

Combined conventional T2-weighted and MnDPDP-enhanced T1-weighted MR cholangiography may eliminate the use of other studies for the imaging of biliary complications after cholecystectomy if this preliminary data can be verified in a larger study.

Pulmonary and Respiratory MedicineMedicine
8
Article|51 citations·2007
Biliary Ductal Involvement of Hilar Cholangiocarcinoma
Eun‐Suk Cho, Mi‐Suk Park, Jeong‐Sik Yu, Myeong‐Jin Kim, Ki Whang Kim
SJR Q3Journal of Computer Assisted TomographyOA

In evaluating the biliary ductal extension of hilar cholangiocarcinoma, MDCT and MRC showed similar accuracies and agreements.

SurgeryMedicine
9
Article|50 citations·2019
Prognostic significance of sarcopenia and skeletal muscle mass change during preoperative chemoradiotherapy in locally advanced rectal cancer
Eric Chung, Hye Sun Lee, Eun‐Suk Cho, Eun Jung Park, Seung Hyuk Baik, Kang Young Lee, Jeonghyun Kang
SJR Q1Clinical NutritionOA
PhysiologyMedicine
10
Article|46 citations·2012
CT Angiography of the Renal Arteries: Comparison of Lower-Tube-Voltage CTA With Moderate-Concentration Iodinated Contrast Material and Conventional CTA
Eun‐Suk Cho, Jeong‐Sik Yu, Jhii-Hyun Ahn, Joo Hee Kim, Jae Bock Chung, Hyeon-Kyeong Lee, Kyung Hee Lee
SJR Q1American Journal of RoentgenologyOA

The use of 80 kVp with moderate-concentration CM could improve arterial enhancement and provide superior image quality with a smaller amount of iodine and a lower radiation dose.

Biomedical EngineeringEngineering
11
Article|42 citations·2023
Albumin‐myosteatosis gauge as a novel prognostic risk factor in patients with non‐metastatic colorectal cancer
Yerim Kim, Jae‐Hoon Lee, Eun‐Suk Cho, Hye Sun Lee, Su‐Jin Shin, Eun Jung Park, Seung Hyuk Baik, Kang Young Lee, Jeonghyun Kang
SJR Q1Journal of Cachexia Sarcopenia and MuscleOA

BACKGROUND: Myosteatosis and systemic inflammation are well-known prognostic factors in patients with colorectal cancer (CRC). The serum albumin level is a reflection of malnutrition and systemic inflammation, which in turn plays a key role in the development of myosteatosis. However, few studies have been conducted on these synergistic effects. This study aimed to examine the individual and synergistic effects of different prognostic markers related to skeletal muscle quality and serum albumin

PhysiologyMedicine
12
Article|40 citations·2011
Detection of small intrahepatic metastases of hepatocellular carcinomas using diffusion-weighted imaging: comparison with conventional dynamic MRI
Jeong‐Sik Yu, Jae Bock Chung, Joo Hee Kim, Eun‐Suk Cho, Dae Jung Kim, Jhii-Hyun Ahn, Ki Whang Kim
SJR Q2Magnetic Resonance ImagingOA
Radiology, Nuclear Medicine and ImagingMedicine
13
Article|37 citations·2023
Combining prognostic nutritional index (PNI) and controlling nutritional status (CONUT) score as a valuable prognostic factor for overall survival in patients with stage I–III colorectal cancer
Harin Kim, Dong Min Shin, Jae‐Hoon Lee, Eun‐Suk Cho, Hye Sun Lee, Su‐Jin Shin, Eun Jung Park, Seung Hyuk Baik, Kang Young Lee, Jeonghyun Kang
SJR Q2Frontiers in OncologyOA

Background and aims This study compared the prognostic significance of various nutritional and inflammatory indicators such as neutrophil-to-lymphocyte ratio, lymphocyte-to-monocyte ratio and platelet-to-lymphocyte ratio, prognostic nutritional index, and controlling nutritional status score. In addition, we aimed to establish a more accurate prognostic indicator. Methods We retrospectively evaluated 1112 patients with stage I–III colorectal cancer between January 2004 and April 2014. The contro

OncologyMedicine
14
Article|27 citations·2013
CT Venography for Deep Vein Thrombosis Using a Low Tube Voltage (100 kVp) Setting Could Increase Venous Enhancement and Reduce the Amount of Administered Iodine
Eun‐Suk Cho, Jae Bock Chung, Sung Jun Kim, Joo Hee Kim, Jeong‐Sik Yu, Choon-Sik Yoon
SJR Q1Korean Journal of RadiologyOA

The 100 kVp setting in CTV substantially help improve venous enhancement and CNR(VEIN). Furthermore, it enables to reduce the amount of administered iodine while maintaining venous attenuation, as compared with the 120 kVp setting.

Internal MedicineMedicine
15
Article|23 citations·2014
Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose
Eun‐Suk Cho, Tae‐Sub Chung, Sung Jun Ahn, KyoungHoon Chong, Jang Hun Baek, Sang Hyun Suh
SJR Q1European RadiologyOA
Radiology, Nuclear Medicine and ImagingMedicine

Research Areas

HepatologySurgeryRadiology, Nuclear Medicine and ImagingOncologyPhysiologyComputer Networks and Communications

Eun Seok Choの研究をNubintでさらに深く

この研究室の論文をアプリで開き、AIと共に読み、要約し、引用しましょう。