Skip to main content

Gyuseong Cho

Korea Advanced Institute of Science and Technology · 物理学・天文学

研究室紹介

Professor Gyuseong Cho's research lab specializes in radiation detection and measurement, with a focus on developing advanced gamma and neutron spectrometers for environmental, personal, and industrial monitoring. The lab emphasizes innovative detector systems using scintillators—such as NaI(Tl) and plastic scintillators—combined with modern readout technologies like silicon photomultipliers (SiPMs) to enhance performance in compact, low-power, and cost-effective designs. Key research directions include pulse pileup correction, ambient dose equivalent estimation, pseudo-gamma spectroscopy using deep learning, and the design of compact, accelerator-driven neutron sources for industrial applications. The lab integrates Monte Carlo simulations, machine learning, and experimental validation to advance radiation detection systems for real-world deployment.

gamma spectrometryscintillator detectorsSiPMneutron sourceradiation monitoring

Research Overview

Papers
400
Total Citations
1,912
Papers (5y)
44
Primary Field
物理学・天文学

Research Output Trend

Figures are computed from collected data and may differ slightly.

Publications per year (5y)
44total
2022
2023
2024
2025
2026
Citations per year (5y)
88total
20222023202420252026

Selected Papers

15
1
Article|65 citations·2019
Multi-radioisotope identification algorithm using an artificial neural network for plastic gamma spectra
Jinhwan Kim, Kyeongjin Park, Gyuseong Cho
SJR Q2Applied Radiation and Isotopes
RadiationPhysics and Astronomy
2
Article|52 citations·2009
Scintillation characteristics and imaging performance of CsI:Tl thin films for X-ray imaging applications
Bo Kyung, Jeong-Hyun Shin, Jun Hyung Bae, Chaehun Lee, Sung-Ho Chang, Hyun Ki Kim, Chan Kyu Kim, Gyuseong Cho
SJR Q2Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
RadiationPhysics and Astronomy
3
Article|40 citations·2019
Quantitative analysis of NaI(Tl) gamma-ray spectrometry using an artificial neural network
Jinhwan Kim, Kyung Taek Lim, Junhyeok Kim, Chang-jong Kim, Byoungil Jeon, Kyeongjin Park, Giyoon Kim, Hojik Kim, Gyuseong Cho
SJR Q2Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
RadiationPhysics and Astronomy
4
Article|33 citations·2007
A study on spatial resolution of pixelated CsI(Tl) scintillator
Byoung-Jik Kim, Bo Kyung, Hosang Jeon, Yong Ki, Gyuseong Cho
SJR Q2Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
RadiationPhysics and Astronomy
5
Article|29 citations·2019
Pulse pileup correction method for gamma-ray spectroscopy in high radiation fields
Minju Lee, Daehee Lee, Eunbie Ko, Kyeongjin Park, Junhyuk Kim, Kilyoung Ko, M. Sharma, Gyuseong Cho
SJR Q2Nuclear Engineering and TechnologyOA

The detector suffers from pulse pileup by overlapping of the signals when it was used in high radiation fields. The pulse pileup deteriorates the energy spectrum and causes count losses due to random coincidences, which might not resolve within the resolving time of the detection system. In this study, it is aimed to propose a new pulse pileup correction method. The proposed method is to correct the start point of the pileup pulse. The parameters are obtained from the fitted exponential curve us

RadiationPhysics and Astronomy
6
Article|24 citations·2019
Ambient dose equivalent measurement with a CsI(Tl) based electronic personal dosimeter
Kyeongjin Park, Jinhwan Kim, Kyung Taek Lim, Junhyeok Kim, Hojong Chang, Hyunduk Kim, M. Sharma, Gyuseong Cho
SJR Q2Nuclear Engineering and TechnologyOA

In this manuscript, we present a method for the direct calculation of an ambient dose equivalent (H*(10)) for the external gamma-ray exposure with an energy range of 40 keV to 2 MeV in an electronic personal dosimeter (EPD). The designed EPD consists of a 3×3 mm2 PIN diode coupled to a 3×3×3 mm3 CsI (Tl) scintillator block. The spectrum-to-dose conversion function (G(E)) for estimating H*(10) was calculated by applying the gradient-descent method based on the Monte-Carlo simulation. The optimal

RadiationPhysics and Astronomy
7
Article|23 citations·2019
Parametric optimization for energy calibration and gamma response function of plastic scintillation detectors using a genetic algorithm
Byoungil Jeon, Jong-Yul Kim, Myungkook Moon, Gyuseong Cho
SJR Q2Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
RadiationPhysics and Astronomy
8
Article|23 citations·2015
Iterative Monte Carlo simulation with the Compton kinematics-based GEB in a plastic scintillation detector
Chankyu Kim, Yewon Kim, Myungkook Moon, Gyuseong Cho
SJR Q2Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
RadiationPhysics and Astronomy
9
Article|22 citations·2021
Pseudo-Gamma Spectroscopy Based on Plastic Scintillation Detectors Using Multitask Learning
Byoungil Jeon, Junha Kim, Eunjoong Lee, Myungkook Moon, Gyuseong Cho
SJR Q1SensorsOA

Although plastic scintillation detectors possess poor spectroscopic characteristics, they are extensively used in various fields for radiation measurement. Several methods have been proposed to facilitate their application of plastic scintillation detectors for spectroscopic measurement. However, most of these detectors can only be used for identifying radioisotopes. In this study, we present a multitask model for pseudo-gamma spectroscopy based on a plastic scintillation detector. A deep- learn

RadiationPhysics and Astronomy
10
Article|20 citations·2008
Performance studies of a monolithic scintillator-CMOS image sensor for X-ray application
Bo Kyung, Jun Hyung Bae, Byoung-Jik Kim, Hosang Jeon, Gyuseong Cho
SJR Q2Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Electrical and Electronic EngineeringEngineering
11
Article|20 citations·1990
Measurements of 1/f Noise in A-Si:H Pin Diodes and Thin-Film-Transistors
Gyuseong Cho, J. Drewery, Ichiro Fujieda, Tao Jing, S.N. Kaplan, V. Perez-Mendez, S. Qureshi, D. Wildermuth, R. A. Street
MRS ProceedingsOA

ABSTRACT We measured the equivalent noise charge of a-Si:H pin diodes (5 ∼ 45 μm i-layer) with a pulse shaping time of 2.5 μ.sec under reverse biases up to 30 V/μm and analyzed it as a four component noise source. The frequency spectra of 1/f noise in the soft-breakdown region and of the Nyquist noise from contact resistance of diodes were measured. Using the conversion equations for a CR-RC shaper, we identified the contact resistance noise and the 1/f noise as the main noise sources in the low

Electrical and Electronic EngineeringEngineering
12
Article|19 citations·2010
The sensitivity and spatial resolution dependence on the microstructures of CsI:Tl scintillation layer for X-ray imaging detectors
Bo Kyung, Jun Hyung Bae, Chaehun Lee, Sung-Ho Chang, Gyuseong Cho
SJR Q2Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
RadiationPhysics and Astronomy
13
Article|18 citations·2019
Efficient design of a ∅2×2 inch NaI(Tl) scintillation detector coupled with a SiPM in an aquatic environment
Junhyeok Kim, Kyeongjin Park, Jisung Hwang, Hojik Kim, Jinhwan Kim, Hyunduk Kim, Sung‐Hee Jung, Young‐Sug Kim, Gyuseong Cho
SJR Q2Nuclear Engineering and TechnologyOA

After the Fukushima accident in 2011, there has been increased public concern about radioactive contamination of water resources through fallout in neighboring countries. However, there is still no available initial response system that can promptly detect radionuclides. The purpose of this research is to develop the most efficient gamma spectrometer to monitor radionuclides in an aquatic environment. We chose a thallium-doped sodium iodide (NaI(Tl)) scintillator readout with a silicon photo mul

RadiationPhysics and Astronomy
14
Article|18 citations·2015
Optimal design of a CsI(Tl) crystal in a SiPM based compact radiation sensor
Hyunjun Yoo, Segyeong Joo, Shi-Young Yang, Gyuseong Cho
SJR Q2Radiation Measurements
RadiationPhysics and Astronomy
15
Article|17 citations·2007
An X-ray imaging detector based on pixel structured scintillator
Byoung-Jik Kim, Gyuseong Cho, Bo Kyung, Bo-Sun Kang
SJR Q2Radiation Measurements
RadiationPhysics and Astronomy

Research Areas

RadiationElectrical and Electronic EngineeringRadiology, Nuclear Medicine and ImagingBiomedical EngineeringPulmonary and Respiratory MedicineMaterials Chemistry

Gyuseong Choの研究をNubintでさらに深く

この研究室の論文をアプリで開き、AIと共に読み、要約し、引用しましょう。