Jiyoung Jeong
Yonsei University · 医療専門職
研究室紹介
Professor Jiyoung Jeong's research lab specializes in health technology and medical imaging innovation, focusing on patient-centered healthcare solutions. The lab investigates digital medical imaging systems, including PACS and CR/DR technologies, to optimize image quality and radiation dose efficiency. It also explores human factors in emerging technologies such as virtual reality, particularly user experience and motion-induced discomfort (cybersickness), and applies this insight to improve immersive technology design. Additionally, the lab examines patient decision-making in clinical contexts, such as autonomy in periodontal treatment and dental implant placement accuracy.
Research Overview
Research Output Trend
Figures are computed from collected data and may differ slightly.
Selected Papers
15This study aims to identify Z-generation's sports consumption behavior in terms of lifestyle and consumption value. The sports consumption was categorized as ‘sports motivation’ and ‘sports involvement’. The sample consists of 356 participants who were born between 1995 and 2010 and have got involved in sports. The data was analyzed by using t-test and one-way ANOVA to assess differences in Gen Z's sports consumption behavior related to their lifestyle and consumption value. The findings show th
가상현실 시장의 빠른 성장에도 불구하고 사이버멀미(Cyber sickness) 증상은 여전히 사용자 경험 차원에서 가장 심각한 문제점이다. 본 연구의 목적은 VR 콘텐츠의 시점과 움직임에 따라 사용자가 느끼는 멀미 증상에 차이가 있는지 확인하는 것이다. 실험 설계를 통해 VR 헤드셋을 착용하고 게임 콘텐츠를 수행할 때 1인칭-3인칭의 시점 조건과 수직축-수평축의 머리 움직임 조건이 사이버 멀미에 영향을 미치는지 검증하였다. 분석 결과 3인칭보다 1인칭 시점에서, 수직축보다 수평축 회전 움직임 조건에서 멀미 증상이 더 심했다. VR 착용시의 시점과 움직임은 사이버 멀미에 영향을 미치지만, 시점과 움직임간의 상호작용은 나타나지 않았다. 이러한 결과에 기반하여 멀미감 감소와 함께 균형있는 VR 사용자 경험을 구축하기 위해 콘텐츠 기획에서 고려해야 실무적 요소들을 제시하였다. 적절 수준의 콘텐츠 몰입을 위한 시각적 디자인, 다중감각 인터페이스 디자인, 체험 마케팅 전략을 통해 VR의 긍정적
BACKGROUND AND AIM: Managing periodontal disease often involves complex decisions involving multiple treatment options, and patient autonomy significantly influences this decision-making process. This study aimed to characterise the autonomy and information-seeking preferences among patients diagnosed with stage III/IV periodontitis, and to identify the factors influencing these preferences. MATERIALS AND METHODS: The survey included 96 patients diagnosed with periodontal disease, all of whom un
최근 의료영상저장 및 전송 시스템(Picture Archiving and Communication System, PACS)의 발전과 함께 디지털 영상의 발 전이 가속화 되면서, 특히 기존의 아날로그 시스템을 활용할 수 있는 컴퓨터 X-선 촬영(Computed Radiography, CR)의 활용도가 높아졌다. 본 연구에서는 실제 임상에서 사용되고 있는 Agfa CR system (Agfa CR 2.5; Agfa, Belgium)과 Fuji CR system (FCR 9000C; Fuji, Japan)을 이용하여 영상의 정량적 평가에 널리 사용되고 있는 변조전달함수(Modulation Transfer Function, MTF), 잡음력스펙트럼(Noise Power Spectrum, NPS), 양자검출효율(Detective Quantum Efficiency, DQE) 를 통해 시스템간의 성능 비교 및 I.P (Imaging Plate) 크기별 픽셀 크기 차이 및 선량의 변화에 의한 화질
CTDIs (computed tomography dose indices) can be directly measured using an ion chamber or can be estimated using computer simulation techniques to the determine radiation dose. The purpose of this study was to demonstrate CTDI estimation by using GATE (geant4 application for tomographic emission) simulations and to extend the techniques to various CT applications. We simulated various phantom sizes to estimate values for different patients. The simulations were performed using a single axial sca
BACKGROUND: The fixture thread depth reportedly influences the primary stability of dental implant, but its effect on the positional accuracy in immediate implant placement has not been reported previously. MATERIALS AND METHODS: Fifty-six single-rooted, anterior and premolar teeth were extracted from six human cadavers, followed by installing either regular-threaded implants (RT group, N = 30) or deep-threaded implants (DT group, N = 26) completely relying on the surgical guide. Optical impress
To identify a proper T-score threshold for the diagnosis of osteoporosis in Koreans using quantitative ultrasonography (QUS), normative data from 240 females and 238 males (ages 20-29 yr) were newly generated. Then, the osteoporosis prevalence estimate for men and women over 50 yr of age was analyzed using previous World Health Organization (WHO) methods and heel QUS. T-scores were calculated from the normative data. There were definite negative correlations between age and all of the QUS parame
Digital radiography has gained popularity in many areas of clinical practice. With this transition has come interest in advancing methodologies for image quality characterization. The modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) are widely accepted measurements of system performance. The NPS is one of the most common metrics describing the noise amplitude and texture observed in images obtained with a uniform field of radiation, ye
본 연구는 MDCT (multi-detector computed tomography) 파라미터 변화에 따른 환자선량을 측정하고 평가 하고자 하였다. MDCT 파라미터의 다양한 변화에 의한 환자선량은 MDCT (GE light speed plus 4 slice, USA)와 model 2026C electrometer (RADICAL 2026C, USA), 그리고 head와 body의 CT선량 표준팬텀(standard polymethylmethacrylate)을 사용하여 측정 하였다. 그 결과 환자선량 CTDIw 값은 관전압과 관전류가 증가할수록 선형적으로 증가하였고 beam collimation이 증가 할수록 감소하였다. 따라서 관전압, 관전류는 환자의 피폭선량에 직접적인 영향을 주고 슬라이스 두께는 영향이 적은 것을 알 수 있었다. 임상의 전형적인 MDCT 복부 scan에서 120 kVp, 180 mAs, 20 mm collimation과 0.75 pitch의 조건하에 CTDIw와
AIM: To compare the dimensional outcomes of horizontal augmentation with the retentive-flap technique using particulate and cross-linked collagenated bone substitutes. MATERIALS AND METHODS: This two-centre, two-arm randomized clinical trial investigated 69 subjects: 34 in the particulate group and 35 in the collagenated group. Patients were randomly assigned to receive single implant placement with simultaneous guided bone regeneration (GBR) using either particulate deproteinized porcine bone m
본 연구는 공통문항 비동등집단 설계에서 이차원성을 갖는 검사자료에 다차원 문항반응모형을 적용한 연계화와 동등화 결과를 집단 간 비동등성, 차원 간 상관정도, 검사구조에 따라 모의실험을 통해 비교하였다. 각 연구조건에 따라 모의자료를 생성한 후 Oshima, Davey와 Lee(2000), Li와 Lissitz(2000), Min(2003)이 제안한 MIRT 연계화 방법을 적용하여 연계화를 시행하고 그 결과를 비교하였다. 이후 각 연계화 방법에 따라 공통 척도로 전환 된 모수를 사용하여 Brossman(2010)의 연구에서 제시한 복합 다차원 문항반응이론 관찰점수 동등화, 다차원 문항반응이론의 일차원적 접근 진점수와 관찰점수 동등화 방법을 적용하여 동등화 결과를 비교하였다. MIRT 연계화 결과를 보면, Oshima, Davey와 Lee 방법이 Li와 Lissitz, Min 방법에 비해 집단 간 비동등성과 차원 간 상관정도에 따라 연계화 결과가 상대적으로 안정적으로 산출되었고, 검사구
현재의 PET/CT 시스템은 양질의 CT 영상을 추가함으로 인하여 기존의 PET 만의 시스템에 비하여 정확한 병소 위치의 지정으로 인한 진단적 가치를 높인 뛰어난 장비로 알려져 있다. 대부분의 PET/CT 시스템은 기존의 PET시스템에서 감쇠 지도를 만들기 위하여 사용하던 68Ge 또는 137Cs 등의 투과선원이 아닌 CT data를 감쇠 지도로 사용함으로 인하여 감쇠보정을 위한 획득시간을 획기적으로 줄여주었다. 그러나 이 감쇠 보정용 CT의 사용은 환자의 피폭선량을 증가시키는 결과를 초래하였다. 본 연구의 목적은 PET/CT 시스템에서 PET 영상의 감쇠지도로 쓰이는 CT를 수행할 경우 원하는 화질을 유지할 수 있는 상태에서의 최저의 관전류값을 평가하는 것이었다. 영상 획득을 위한 기기로는 GE DSTe PET/CT 시스템을 사용하였다. 본 연구를 위하여 3D 호프만 팬텀과 원통형 팬텀에 1.190 mCi의 18F-FDG를 주입하여 PET 영상 및 CT 영상을 획득하였으며 관전류를
본 연구는 MDCT에서 선량을 측정하는데 사용되는 ionization chamber의 calibration 전과 후의 calibration factor에 따른 선량과 촬영실의 온도, 기압의 보정(correction factor) 적용 유무에 따른 CTDIW를 비교 분석하는데 있다. 2007년 3월 21일에 교정된 Model 2026C electrometer (RADICAL 2026C, USA)를 이용한 MDCT (GE light speed plus 4 slice, USA)와 head and body CT dosimetry phantom을 사용하여 측정된 값을 비교 분석 하였다. 결과는 calibration factor와 주변 온도, 압력의 correction factor를 보정 해 준 CTDIW 값이 보정을 하지 않고 계산된 값보다 0.479 ~ 3.162 mGy의 범위만큼 더 많은 선량 값이 계산되었고 실제 병원에서 사용하는 복부 일반 CT (abdomen routine CT) 조
Purpose: This study aimed to develop and evaluate a structured shared decision-making (SDM) protocol tailored for patients with periodontally compromised teeth. Given the complexity and irreversibility of dental treatment decisions, particularly those involving tooth preservation or extraction, this protocol is designed to align clinical judgment with patient values through a standardized approach applicable to real-world dental settings.Current Concepts: Although various treatment options are a