Kun Yung Kim
Seoul National University · 医学
研究室紹介
Professor Kun Yung Kim's research lab specializes in interventional radiology and minimally invasive therapies, focusing on the development and evaluation of endovascular and endoluminal stents for treating malignant strictures and fistulas. The lab investigates drug-eluting and biodegradable stents to reduce restenosis and granulation tissue formation, with applications in the esophagus, urethra, and peripheral vasculature. Additionally, the lab explores innovative ablation techniques, such as cryoablation for lung nodules, and embolization strategies for degenerative joint diseases, emphasizing patient-centered palliative care and improved clinical outcomes.
Research Overview
Research Output Trend
Figures are computed from collected data and may differ slightly.
Selected Papers
15Esophageal stents have been used to palliate patients with dysphagia caused by esophageal cancer. Early rigid plastic prostheses have been associated with a high risk of complications. However, with the development of self-expanding stents, it has developed into a widely accepted method for treating malignant esophageal strictures and esophagorespiratory fistulas (ERFs). The present review covers various aspects of self-expanding metallic stent placement for palliating esophageal cancer, includi
Purpose To investigate the use of sirolimus-eluting biodegradable stents (SEBSs) to suppress granulation tissue formation after stent placement in a rat urethral model. Materials and Methods All experiments were approved by the animal research committee. A total of 36 male Sprague-Dawley rats were randomized into three equal groups after biodegradable stent placement. Group A received control biodegradable stents. Groups B and C received stents coated with 90 µg/cm<sup>2</sup> and 450 µg/cm<sup>
BACKGROUND: Knee osteoarthritis (OA) is accompanied by inflammation and angiogenesis. Modifying angiogenesis through transcatheter arterial embolization (TAE) can be a potential treatment for knee OA. OBJECTIVE: We subjected five OA knees in three patients to TAE and report the results of our post-treatment observations. CASE DESCRIPTION: Three patients that had experienced knee pain for a minimum of one year prior to the study, and whose pain had persisted despite conservative treatment, were i
Placing a self-expandable metallic stent (SEMS) is safe and effective for the palliative treatment of malignant gastroduodenal (GD) strictures. SEMS abutment in the duodenal wall is associated with increased food impaction, resulting in higher stent malfunction and shorter stent patency. The desire to evaluate the mechanism and significance of stent abutment led us to design an in vitro experiment using a flexible anthropomorphic three-dimensional (3D)-printed GD phantom model. A GD phantom was
Treatments for pure ground-glass nodules (GGNs) include limited resection; however, surgery is not always possible in patients with limited pulmonary functional reserve. In such patients, cryoablation may be a suitable alternative to treat a pure GGN. Here, we report our initial experience with cryoablation of a pure GGN that remained after repeated surgical resection in a patient with multiple GGNs. A 5-mm-sized pure GGN in the left lower lobe was cryoablated successfully without recurrence at
Purpose of this study was to compare the complication rates between reverse-tapered and nontapered peripherally inserted central catheters (PICCs). In total, 407 patients who had an inpatient clinic-based PICC insertion between September 2019 and November 2019 were retrospectively analyzed. Seven PICC types were used (4 reverse tapered: 4-Fr single-lumen (n = 75), 5-Fr single-lumen (n = 78), 5-Fr double-lumen (n = 62), and 6-Fr triple-lumen (n = 61); 3 nontapered: 4-Fr single-lumen (n = 73), 5-F
A canine model may be appropriate for intranodal lymphangiography and TD access. Most lymphatic intervention techniques can be performed in a canine using the same instruments that are employed in a clinical setting.