Skip to main content

Kyung Nam Kim

Yonsei University · 医学

研究室紹介

Professor Kyung Nam Kim's research lab specializes in biomaterials and biomedical engineering, with a focus on developing corrosion-resistant and biocompatible materials for ophthalmic and orthodontic applications. The lab investigates the electrochemical behavior, cytotoxicity, and long-term stability of metal alloys—particularly titanium-silver and super stainless steels—under physiological conditions. Additionally, the lab explores the health impacts of environmental exposures, such as air pollutants and endocrine-disrupting chemicals like bisphenol A, on metabolic and respiratory health, especially in aging populations. The research integrates materials science with clinical and environmental health outcomes to advance medical device safety and public health interventions.

biomaterialscorrosion resistanceenvironmental healthorthopedic/orthodontic materialselectrochemical properties

Research Overview

Papers
332
Total Citations
2,708
Papers (5y)
24
Primary Field
医学

Research Output Trend

Figures are computed from collected data and may differ slightly.

Publications per year (5y)
24total
2021
2022
2023
2024
2026
Citations per year (5y)
67total
20212022202320242026

Selected Papers

15
1
Article|78 citations·2013
Comparison of the new rebound tonometer with Goldmann applanation tonometer in a clinical setting
Kyoung Nam Kim, Jin Wook Jeoung, Ki Ho Park, Min Kyu Yang, Dong‐Myung Kim
SJR Q1Acta OphthalmologicaOA

PURPOSE: To evaluate the clinical usefulness of a new rebound tonometer, Icare(®) PRO (Icare PRO), by comparison with Goldmann applanation tonometry (GAT) in a study on patients with glaucoma. METHODS: One hundred and seventy-two eyes of 86 subjects were enrolled in this study. All of the subjects were examined with an autorefractometer, Icare PRO, slit-lamp biomicroscope, GAT, ultrasound A-scan and pachymeter. Three intraocular pressure (IOP) measurements were obtained by Icare PRO and GAT. The

Radiology, Nuclear Medicine and ImagingMedicine
2
Article|76 citations·2012
Effect of Lateral Decubitus Position on Intraocular Pressure in Glaucoma Patients with Asymmetric Visual Field Loss
Kyoung Nam Kim, Jin Wook Jeoung, Ki Ho Park, Dae Seung Lee, Dong‐Myung Kim
SJR Q1Ophthalmology
OphthalmologyMedicine
3
Article|71 citations·2017
Non-thermal atmospheric pressure plasma functionalized dental implant for enhancement of bacterial resistance and osseointegration
Jung‐Hwan Lee, Won-Seok Jeong, Seog-Jin Seo, Hae‐Won Kim, Kyoung Nam Kim, Kyoung-Nam Kim, Eun Ha Choi, Kwang‐Mahn Kim, Kwang‐Mahn Kim
SJR Q1Dental MaterialsOA
Radiology, Nuclear Medicine and ImagingMedicine
4
Article|66 citations·2015
Changes in corneal endothelial cell density and the cumulative risk of corneal decompensation after Ahmed glaucoma valve implantation
Kyoung Nam Kim, Sung Bok Lee, Yeon Hee Lee, Jong Joo Lee, Hyung Bin Lim, Chang Sik Kim
SJR Q1British Journal of Ophthalmology

In case of uncomplicated AGV implantation, the cumulative risk of corneal decompensation was 3.3%, 5 years after the operation. The ECD loss was statistically greater in eyes with AGV than in control eyes without AGV, but the difference was significant only up to 2 years post surgery.

OphthalmologyMedicine
5
Article|65 citations·2015
Physical Activity- and Alcohol-dependent Association Between Air Pollution Exposure and Elevated Liver Enzyme Levels: An Elderly Panel Study
Kyoung Nam Kim, Hye‐Mi Lee, Jin Hee Kim, Kweon Jung, Youn-Hee Lim, Yun‐Chul Hong
SJR Q2Journal of Preventive Medicine and Public HealthOA

Short-term exposure to air pollutants such as PM2.5, NO2, and O3 is associated with increased liver enzyme levels in the elderly. These adverse effects can be reduced by exercising regularly and abstinence from alcohol.

Public Health, Environmental and Occupational HealthMedicine
6
Article|65 citations·2005
Properties of titanium–silver alloys for dental application
Keun‐Taek Oh, Hyung‐Min Shim, Kyoung Nam Kim
SJR Q2Journal of Biomedical Materials Research Part B Applied BiomaterialsOA

The purpose of this study was to develop titanium-silver alloys with biocompatibility, high corrosion resistance, and low ion-release rate, and to evaluate the electrochemical properties of titanium-silver alloys in artificial saliva. Titanium-silver alloys with silver contents ranging from 0 to 4.5 at % in steps of 0.5 at % were designed. The alloys were arc melted, homogenized at 950 degrees C for 72 h, hot rolled to 2 mm in thickness, and finally solution heat treated at 950 degrees C for 1 h

Materials ChemistryMaterials Science
7
Article|50 citations·2004
Properties of super stainless steels for orthodontic applications
Keun‐Taek Oh, Young‐Sik Kim, Yong‐Soo Park, Kyoung Nam Kim
SJR Q2Journal of Biomedical Materials Research Part B Applied BiomaterialsOA

Orthodontic stainless-steel appliances are considered to be corrosion resistant, but localized corrosion can occur in the oral cavity. This study was undertaken to evaluate the properties of super stainless steels in orthodontic applications. Accordingly, the metallurgical properties, mechanical properties, corrosion resistance, amount of the released nickel, cytotoxicity, and characteristics of the passive film were investigated. Corrosion resistances of the specimens were high and in the follo

Metals and AlloysMaterials Science
8
Article|43 citations·2013
Relationship Between Preferred Sleeping Position and Asymmetric Visual Field Loss in Open-Angle Glaucoma Patients
Kyoung Nam Kim, Jin Wook Jeoung, Ki Ho Park, Dong‐Myung Kim, Robert Ritch
SJR Q1American Journal of Ophthalmology
EpidemiologyMedicine
9
Article|37 citations·2014
Bisphenol A Exposure and Asthma Development in School-Age Children: A Longitudinal Study
Kyoung Nam Kim, Jin Hee Kim, Ho‐Jang Kwon, Soo‐Jong Hong, Byoung‐Ju Kim, So Yeon Lee, Yun‐Chul Hong, Sanghyuk Bae
SJR Q1PLoS ONEOA

Increased urinary bisphenol A concentrations at 7-8 years old were positively associated with wheezing and asthma and negatively associated with PC20 at ages up to 11-12 years.

Health, Toxicology and MutagenesisEnvironmental Science
10
Article|36 citations·2004
Proliferation, differentiation, and calcification of preosteoblast‐like MC3T3‐E1 cells cultured onto noncrystalline calcium phosphate glass
Yong‐Keun Lee, Jin Sung Song, Sang Bae Lee, Kwang‐Mahn Kim, Kwang‐Mahn Kim, Seong‐Ho Choi, Chong‐Kwan Kim, Racquel Z. LeGeros, Kyoung Nam Kim, Kyoung Nam Kim
SJR Q1Journal of Biomedical Materials Research Part AOA

The purpose of this study was to investigate calcium phosphate glass as a potential biomaterial for hard tissue repair. We prepared calcium phosphate glass using the system CaO-CaF(2)-P(2)O(5)-MgO-ZnO and cultured MC3T3-E1 cells onto the glass in alpha-MEM with beta-glycerophosphatase and ascorbic acid. Proliferation of the cells was determined to evaluate the biocompatibility of the prepared calcium phosphate glass. The alkaline phosphatase activity was measured to examine the osteoblast differ

Biomedical EngineeringEngineering
11
Article|30 citations·2008
Rhodamine B Hydrazide Revisited: Chemodosimetric Hg2+-selective Signaling Behavior in Aqueous Environments
Kyoung Nam Kim
SJR Q2Bulletin of the Korean Chemical SocietyOA

The well-known Cu2+-selective chemodosimetric behavior of rhodamine B hydrazide was successfully switched to selectivity for Hg2+. The fluorescence signaling is remarkably selective toward Hg2+ ions compared to other common biologically and environmentally important metal ions, including Cu2+ ions. The detection limit was 0.2 mM in an acetate-buffered aqueous 10% methanol solution at pH 5. The OFF-ON type of signaling is due to the selective Hg2+-induced hydrolysis of the lactam ring of the hydr

SpectroscopyChemistry
12
Article|20 citations·2011
스마트폰의 특성이 개인의 업무성과에 미치는영향과 혁신 저항성의 조절효과
김경남, 박지혜, 정도범

This study analyzed the effects of smart phone using for business on work performance in the field. We classified functional and practical aspects of smart phone affecting employee's work performance through former studies. As independent variables, we selected portability of equipment, rapidity of information and ease of use for functional side, and selected fit to work and subjective norms for practical side. And dependent variable was work performance. We also suggested that innovation resist

13
Article|20 citations·2020
Prenatal and early childhood phthalate exposures and thyroid function among school-age children
Kyoung Nam Kim, Hwa Young Kim, Youn-Hee Lim, Choong Ho Shin, Johanna Inhyang Kim, Bung-Nyun Kim, Young Ah Lee, Yun‐Chul Hong
SJR Q1Environment InternationalOA

Our findings suggest that early life phthalate exposure influences subsequent thyroid function. However, the results should be interpreted cautiously, because a single spot urine sample was used to quantify the phthalate exposures at each time point.

Health, Toxicology and MutagenesisEnvironmental Science
14
Article|19 citations·2009
A Simple Phenol‐Indole Dye as a Chromogenic Probe for the Ratiometric Determination of Water Content in Organic Solvents
Kyoung Nam Kim
SJR Q2Bulletin of the Korean Chemical SocietyOA

A simple dye having phenol and indole moieties was synthesized and its chromogenic signaling behaviors for the determination of water content in organic solvents were investigated. The compound revealed a pronounced chromogenic behavior in response to the variation of water content in water miscible aprotic organic solvents of acetone, acetonitrile, THF, and dioxane. Significant red shifts and changes in absorption spectra allowed a ratiometric analysis of the signaling behavior. The chemosensin

SpectroscopyChemistry
15
Article|17 citations·2016
Bone Regeneration Using a Mixture of Silicon-Substituted Coral HA and β-TCP in a Rat Calvarial Bone Defect Model
Ji‐Yeon Roh, Ji‐Youn Kim, Young-Muk Choi, Seong-Min Ha, Kyoung Nam Kim, Kyoung-Nam Kim, Kwang-Mahn Kim, Kwang-Mahn Kim
SJR Q2MaterialsOA

The demand of bone graft materials has been increasing. Among various origins of bone graft materials, natural coral composed of up to 99% calcium carbonate was chosen and converted into hydroxyapatite (HA); silicon was then substituted into the HA. Then, the Si-HA was mixed with β-tricalcium phosphate (TCP) in the ratios 100:0 (S100T0), 70:30 (S70T30), 60:40 (S60T40), and 50:50 (S50T50). The materials were implanted for four and eight weeks in a rat calvarial bone defect model (8 mm). The MBCPT

Biomedical EngineeringEngineering

Research Areas

Biomedical EngineeringOphthalmologyRadiology, Nuclear Medicine and ImagingSurgeryOrthodonticsMaterials Chemistry

Kyung Nam Kimの研究をNubintでさらに深く

この研究室の論文をアプリで開き、AIと共に読み、要約し、引用しましょう。