Skip to main content

Minji Kim

Ewha Womans University · 歯学

研究室紹介

Professor Minji Kim's research lab specializes in digital dentistry and oral health technology, focusing on the accuracy, reliability, and clinical application of intraoral scanning systems. The lab investigates the impact of anatomical variables—such as bracket type, interdental spacing, and oral environment—on digital impression quality, while also exploring the integration of digital colorimetry and biomaterials in restorative dentistry. A key research direction involves evaluating digital tools for shade matching and 3D image accuracy, aiming to improve diagnostic precision and treatment outcomes in clinical practice.

intraoral scanningdigital dentistry3D imaging accuracyshade matchingoral biomaterials

Research Overview

Papers
222
Total Citations
2,321
Papers (5y)
85
Primary Field
歯学

Research Output Trend

Figures are computed from collected data and may differ slightly.

Publications per year (5y)
85total
2022
2023
2024
2025
2026
Citations per year (5y)
278total
20222023202420252026

Selected Papers

15
1
Article|84 citations·2010
Hypocholesterolemic effects of curcumin via up-regulation of cholesterol 7a-hydroxylase in rats fed a high fat diet
김민지, 김양하

There is an increasing interest in curcumin (Curcuma longa L.) as a cardiovascular disease (CVD) protective agent via decreased blood total cholesterol and low-density lipoprotein-cholesterol (LDL-cholesterol) level. The aim of this study was to investigate further the potential mechanism in the hypocholesterolemic effect of curcumin by measuring cholesterol 7a-hydroxylase (CYP7A1), a rate limiting enzyme in the biosynthesis of bile acid from cholesterol, at the mRNA level. Male Sprague-Dawley r

2
Article|78 citations·2018
Accuracy of bracket positions with a CAD/CAM indirect bonding system in posterior teeth with different cusp heights
Ji Yeon Kim, Youn-Sic Chun, Minji Kim
SJR Q1American Journal of Orthodontics and Dentofacial Orthopedics
OrthodonticsDentistry
3
Article|77 citations·2012
Volumetric Changes in the Upper Airway After Bimaxillary Surgery for Skeletal Class III Malocclusions: A Case Series Study Using 3-Dimensional Cone-Beam Computed Tomography
Yoonjung Lee, Youn-Sic Chun, Nara Kang, Minji Kim
SJR Q1Journal of Oral and Maxillofacial Surgery
PhysiologyMedicine
4
Article|76 citations·2013
Condylar Positional Changes Up to 12 Months After Bimaxillary Surgery for Skeletal Class III Malocclusions
Yeon-Joo Kim, Yoonjung Lee, Youn-Sic Chun, Nara Kang, Sun-Jong Kim, Minji Kim
SJR Q1Journal of Oral and Maxillofacial Surgery
Complementary and Manual TherapyHealth Professions
5
Article|60 citations·2015
Changes in views on digital intraoral scanners among dental hygienists after training in digital impression taking
Hye-Ran Park, Ji‐Man Park, Youn-Sic Chun, Kkot-Nim Lee, Minji Kim
SJR Q1BMC Oral HealthOA

BACKGROUNDS: Despite the rapid development of digital dentistry, the use of digital intraoral scanners remains limited. The aim of this study was to evaluate the changes in views on intraoral scanners among dental hygienists after training. METHODS: Thirty-four dental hygienists with >3 years of clinical experience participated and were divided into 2 groups : iTero and Trios groups. Participants of each group practiced the usage of both intraoral scanners, for total 12 times over 4 sessions, Qu

General DentistryDentistry
6
Article|60 citations·2016
A Study on Possibility of Clinical Application for Color Measurements of Shade Guides Using an Intraoral Digital Scanner
Hyung‐In Yoon, Ji‐Won Bae, Ji‐Man Park, Youn‐Sic Chun, Mi Ae Kim, Minji Kim
SJR Q1Journal of Prosthodontics

PURPOSE: To assess if color measurement with intraoral scanner correlates with digital colorimeter and to evaluate the possibility of application of a digital scanner for shade selection. MATERIALS AND METHODS: The L*a*b* values of the five shade tabs (A1, A2, A3, A3.5, and A4) were obtained with an intraoral scanner (TRIOS Pod) and a colorimeter (ShadeEye). Both devices were calibrated according to the manufacturer's instructions before measurements. Color measurement values were compared with

OrthodonticsDentistry
7
Article|40 citations·2020
Accuracy on Scanned Images of Full Arch Models with Orthodontic Brackets by Various Intraoral Scanners in the Presence of Artificial Saliva
Jihu Song, Minji Kim
SJR Q2BioMed Research InternationalOA

AIM: . Four study models were prepared; bonded with ceramic, metal, and resin brackets, respectively, and without brackets. Reference images were taken by scanning the models with an industrial scanner. Study models were then applied with an artificial saliva and scanned 10 times, respectively, with the above 4 intraoral scanners. All images were converted to STL file format and analyzed with 3D analysis software. By superimposing with the reference images, mean maximum discrepancy values and me

OrthodonticsDentistry
8
Article|36 citations·2010
Three-dimensional evaluation of soft tissue changes after mandibular setback surgery in class III malocclusion patients according to extent of mandibular setback, vertical skeletal pattern, and genioplasty
Minji Kim, Dong-Yul Lee, Yong-Kyu Lim, Seung‐Hak Baek
Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology
OrthodonticsDentistry
9
Article|36 citations·2016
Impact of Orthodontic Brackets on the Intraoral Scan Data Accuracy
Ji‐Man Park, Shin-Ae Choi, Ji-Yun Myung, Youn-Sic Chun, Minji Kim
SJR Q2BioMed Research InternationalOA

This study aims to compare the impact of buccal and lingual brackets on the accuracy of dental arch data acquired by 4 different digital intraoral scanners. Two pairs of dental casts, one with buccal brackets and the other with lingual brackets, were used. Digital measurements of the 3D images were compared to the actual measurements of the dental models, which were considered standard values. The horizontal measurements included intercanine widths and intermolar widths. The Mann–Whitney<mml:mat

OrthodonticsDentistry
10
Article|35 citations·2010
Diversity of fungi in creosote-treated crosstie wastes and their resistance to polycyclic aromatic hydrocarbons
Minji Kim, Hwanhwi Lee, Yong‐Seok Choi, Gyu-Hyeok Kim, Na-Yoon Huh, Sang-Joon Lee, Young Woon Lim, Sung-Suk Lee, Jae‐Jin Kim
SJR Q3Antonie van Leeuwenhoek
Cell BiologyBiochemistry, Genetics and Molecular Biology
11
Article|32 citations·2017
Analysis on the Accuracy of Intraoral Scanners: The Effects of Mandibular Anterior Interdental Space
Ji-hye Chun, Ji Hyun Tahk, Youn-Sic Chun, Ji‐Man Park, Minji Kim
SJR Q2Applied SciencesOA

In this study, we evaluated the effects of mandibular anterior interdental space on the accuracy of intraoral scanners. Four models of mandibular arch with varying distances of anterior interdental space were analyzed; incisors were evenly spaced out between the two canines by 0 mm, 1 mm, 3 mm, and 5 mm. The full arch of each model was scanned 10 times with iTero® and Trios®. The images were superimposed with those from the reference scanner (Sensable S3) and compared using Geomagic Verify. Stat

OrthodonticsDentistry
12
Article|32 citations·2023
Diagnosis of Alzheimer Disease and Tauopathies on Whole-Slide Histopathology Images Using a Weakly Supervised Deep Learning Algorithm
Minji Kim, Hiroaki Sekiya, Gary Yao, Nicholas B. Martin, Monica Castanedes‐Casey, Dennis W. Dickson, Tae Hyun Hwang, Shunsuke Koga
SJR Q1Laboratory InvestigationOA
Artificial IntelligenceComputer Science
13
Article|26 citations·2013
미디어, 관계성과 이미지회복전략이 공중의 위기커뮤니케이션 수용에 미치는 영향: 신문과 트위터(Twitter) 비교 분석 중심
김민지, 김영욱

위기 상황에서 다수의 공중들이 소셜미디어를 통해 정보를 공유하고, 이를 활용하여 커뮤니케이션을 하는 경향이 증가하고 있음에도 불구하고, 수용자 측면에서 소셜미디어의 영향력을 실증적으로 규명하고자 하는 연구가 거의 없었다. 따라서이 연구는 소셜미디어가 조직의 위기관리에서 어떠한 영향력을 발휘할 수 있는지를 알아보는데 그 목적이 있다. 이를 위해 미디어 유형에 따라 조직-공중 관계성과 조직이 위기 상황에서 내세우는 이미지회복전략의 차이가 공중의 위기커뮤니케이션 수용에 미치는 영향을 알아보고자 하였다. 이를 검증하기 위해 신문과 트위터를 중심으로 구체적인 위기 상황을 제시한 후 실험을 진행하였다. 삼원변량분석(3-way ANOVA) 결과, 미디어 유형과 이미지회복전략 변인은 공중의위기인식에서 상호작용 효과가 나타났다. 또한 미디어 유형, 조직-공중 관계성, 이미지회복전략 세 변인은 공중의 위기커뮤니케이션 수용에서 상호작용 효과를 나타냈다. 결과적으로 미디어 유형에 따라 공중의 위기인식과

14
Article|26 citations·2018
Comparison of the occlusal contact area of virtual models and actual models: a comparative in vitro study on Class I and Class II malocclusion models
Hye‐Min Lee, Jooly Cha, Youn-Sic Chun, Minji Kim
SJR Q1BMC Oral HealthOA

The occlusal registration of virtual models taken by intraoral scanners sometimes shows patterns which seem much different from the patients’ occlusion. Therefore, this study aims to evaluate the accuracy of virtual occlusion by comparing virtual occlusal contact area with actual occlusal contact area using a plaster model in vitro. Plaster dental models, 24 sets of Class I models and 20 sets of Class II models, were divided into a Molar, Premolar, and Anterior group. The occlusal contact areas

OrthodonticsDentistry
15
Review|14 citations·2020
Developing evidence-based clinical imaging guidelines of justification for radiographic examination after dental implant installation
Minji Kim, Sam-Sun Lee, Miyoung Choi, Hwan Seok Yong, Chena Lee, Jo‐Eun Kim, Min-Suk Heo
SJR Q2BMC Medical ImagingOA

BACKGROUND: This study aimed to develop evidence-based clinical imaging guidelines to assess the proper implant location following implant surgery and identify potential complications during follow-up. METHODS: The guideline development process employed an adaptation methodology in accordance with the Korean clinical imaging guidelines (K-CIG). Core (Ovid-Medline, Ovid-Embase, National Guideline Clearinghouse, and Guideline International Network) and domestic databases (KoreaMed, KMbase, and KoM

Oral SurgeryDentistry

Research Areas

OrthodonticsOral SurgeryPeriodonticsFood SciencePublic Health, Environmental and Occupational HealthArtificial Intelligence

Minji Kimの研究をNubintでさらに深く

この研究室の論文をアプリで開き、AIと共に読み、要約し、引用しましょう。