Skip to main content

Sanghun Park

Seoul National University · 社会科学

研究室紹介

Professor Sanghun Park's research lab specializes in sustainable building technologies with a focus on radiant heating and cooling systems, particularly Thermally Activated Building Systems (TABS) and Radiant Ceiling Panel Systems (RCPS). The lab investigates thermal performance, energy efficiency, and indoor thermal comfort through advanced analytical modeling, experimental validation, and building energy simulation. Research directions include optimizing thermal mass utilization, load shifting via time-lag effects, and improving system design for residential and commercial buildings under varying climatic and occupancy conditions.

TABSradiant coolingthermal performancebuilding energy efficiencythermal modeling

Research Overview

Papers
11
Total Citations
20
Papers (5y)
10
Primary Field
社会科学

Research Output Trend

Figures are computed from collected data and may differ slightly.

Publications per year (5y)
10total
2010
2012
2013
2014
2023
Citations per year (5y)
20total
20102012201320142023

Selected Papers

11
1
Article|8 citations·2010
구체축열시스템의 설계인자 조합에 따른 방냉량 영향도 분석에 관한 연구
박상훈, 김일민, 구소영, 김광우, 여명석
http://www.auric.or.kr/user/rdoc/doc_rdoc_kci.asp?catvalue=3&returnVal=RD_R&page=1&dn=244451

The Radiant heating and cooling system could save building energy by using the mechanism of radiant heat transfer. TABS(Thermally Activated Building System) is one of the radiant heating and cooling system. The main difference between the other radiant system and TABS is the usage of the time-lag effect by storing heat energy at the concrete. It enables the building to shift peak loads to night time. Because TABS are installed at the building structure there are some considerations when design T

2
Article|4 citations·2012
공동주택의 단열 및 차양에 따른 구체축열시스템 냉방성능 평가
유미혜, 여명석, 이유지, 정웅준, 박상훈, 김광우

Thermally Activated Building System(TABS) is a radiant heating and cooling system which uses structures as thermal storage by embedding pipes in a concrete slab. Using TABS as the cooling system in residential buildings can reduce energy consumption and peak loads. But the ratio of cooling loads handled by TABS is low in the residential buildings which are significantly influenced by outside condition because condensation and over-cooling may occur. However,recent interest on energy-saving build

3
Article|2 citations·2014
천장 복사 패널시스템의 방냉량 평가 실험
박상훈, 김동우, 여명석, 김광우
대한건축학회논문집

The radiant ceiling panel system (RCPS) is a light-weight type of radiant heating and cooling system which uses a ceiling as a radiant surface. To obtain improved thermal comfort and maintain the room temperature comfortably, it is important to estimating the cooling capacity of the RCPS. The purpose of this study is to presents an experimental methodology to estimate the cooling performance of the RCPS. This paper also presents an estimation result of the cooling capacity of the RCPS using the

4
Article|2 citations·2012
주거건물의 냉방 부하 패턴에 따른 구체축열시스템 운전 방안
박상훈, 여명석, 유미혜, 이유지, 정웅준, 김광우

Compared to Packaged Terminal Air Conditioning Systems, Radiant Cooling Systems have the advantage of energy saving and thermal comfort. Thermally Activated Building System (TABS) is one of the radiant heating and cooling systems. The main difference between TABS and other radiant systems lies in the usage of the time-lag effect of storing heat energy in the concrete. Current energy usage in summer time is concentrated within a specific time by using Packaged Terminal Air-Conditioner (PTAC). Due

5
Article|2 citations·2023
Workplace Violence Experienced by Community Mental Health Workers
Heeseung Choi, Soyoun Shin, Junhee Jeon, Haewoo Lee, Jong-Eun Lee, Chonghee Seo, Sumi Kim, Sanghoon Park, So Hyun Woo
SJR Q2Issues in Mental Health Nursing

A cross-sectional online survey was conducted to 1) investigate the prevalence of workplace violence and workers' emotional distress, 2) explore factors associated with workplace violence, and 3) assess workers' needs for preventive measures. A total of 763 community mental health workers participated in Korea. Among them, 85.85% of workers experienced workplace violence, including verbal (74.31%), emotional (66.45%), infectious (47.44%), informational (42.60%), sexual (32.50%), and physical (23

Sociology and Political ScienceSocial Sciences
6
Article|1 citations·2014
천장 복사 패널의 유형에 따른 방냉량 평가에 관한 연구
박상훈, 김동우, 여명석, 김광우
대한건축학회논문집

The Radiant Ceiling Panel (RCP) is a type of radiant cooling system that uses a ceiling as a radiant surface for radiant heat exchange. The RCP has advantages of energy saving and reduced size of blow fans due to the reduced distribution energy. Also, it is not affected by interior partitions or zoning. Today, an increasing interest is being shown to extend the application of RCP, in order to save on the initial investment cost and to avoid the use of HVAC systems that cause uncomfortable air fl

7
Article|1 citations·2013
엑세스플로어 일체형 복사난방패널의 열성능 예측을 위한 열해석
최소원, 김광우, 여명석, 박상훈, 김동우, 안민철
대한건축학회논문집

The purpose of this study is to propose an 3-dimensional analytical model for analyzing heating performance of the access floor integrated radiant model. Proposed analytical unit model was divided into several control volumes considering material and shape of the panel components, and then thermal resistance network model is applied. The numerical analysis was carried out using finite volume method which satisfies heat balance equation. Proposed method was evaluated its suitability by comparing

8
Article|0 citations·2005
스펙트랄 분해를 응용한 폴리곤 메쉬의 워터마킹
손정교, 최형인, 김태완, 권성화, 박상훈, 신헌주

그래픽, 오디오, 텍스트 정보 등의 저작권 보호를 위해 사용되어오던 디지털 워터마킹은 이제 기하 정보의 저작권을 보호하는데에도 중요하게 쓰이게 되었다. 스펙트랄 영역에서의 다각형 모델에 대한 워터마킹은 여러 가지 공격에 대하여 강건함을 갖는다. 우리는 기존의 스펙트랄 영역에서의 워터마킹 기법을 일반화하고 이에 기반한 새로운 방법을 제시한다. 워터마크를 삽입 할 때에 라플라시안 행렬의 고유값과 고유벡터를 찾지 않는다. 대신 스케일링 함수로부터 얻어진 선형작용소를 사용한다. 테스트 결과는 서로 상충되는 워터마크를 삽입하고 추출하는데 드는 비용과 공격에 대한 강건성을 어떻게 조정하였는지 보여준다.

9
Article|0 citations·2012
주거건물의 구체축열시스템 적용 시 비정상상태 해석을 반영한 설계 방법에 관한 연구
이유지, 유미혜, 정웅준, 박상훈, 여명석, 김광우
대한건축학회논문집

The thermally activated building system (TABS) is a thermal storage that uses the concrete slab to reduce the peak cooling load. A radiant cooling/heating system is typically designed with consideration on a peak load in a steady state to size the capacity. However, the design of the TABS should consider the time-lag effect due to the high heat capacity of the concrete slab in an un-steady state. Temperature of the concrete slab cannot be changed instantly, which may cause overcooling, overheati

10
Article|0 citations·2014
Component Analysis of Thermally Activated Building System in Residential Buildings
정웅준, 이유지, 유미혜, 박상훈, 여명석, 김광우
Architectural Research

The packaged terminal air conditioner, the typical cooling system for the residential buildings, consumes a large amount of electricity in a short period time during peak hours. In order to reduce the peak load and conserve the electricity, the thermally activated building system can be used as a secondary system to handle the partial cooling load. However, the thermally activated building system may cause condensation and under-cooling. Thus, design of both systems should be performed with care

11
Article|0 citations·2014
하절기 단열 성능 향상을 위한 통기성 지붕의 통기 구조에 관한 실험적 연구
박상훈, 조구상, 이선우, 여명석, 김광우
대한건축학회논문집

The thermal performance of the building envelope is mainly required for guaranteeing a comfortable and hygienic interior climate. A roof is a part of the building envelope which provides protection from the thermal damage of the sun. To improve this protection ability, we can consider using a ventilated roof, which has a ventilation layer known as a cavity, beneath the roof cover panel. The objective of this study is to evaluate the influence of such factors as the slope of the roof, size or sha