Skip to main content

Sewook Pyo

Yonsei University · 歯学

研究室紹介

Professor Sewook Pyo's research lab specializes in digital and regenerative dentistry, focusing on the advancement of computer-guided implant surgery, osseointegration, and biomaterials for alveolar bone regeneration. The lab investigates implant accuracy through advanced imaging and stability assessment techniques, such as cone beam CT and damping capacity analysis, while also exploring photofunctionalization and novel bone graft substitutes like octacalcium phosphate to enhance peri-implant bone formation. A key emphasis is placed on improving clinical outcomes through digital workflows in implant-supported prosthetics and objective evaluation of tooth and implant stability.

dental implantologyosseointegrationdigital dentistrybone regenerationimplant stability

Research Overview

Papers
31
Total Citations
285
Papers (5y)
21
Primary Field
歯学

Research Output Trend

Figures are computed from collected data and may differ slightly.

Publications per year (5y)
21total
2022
2023
2024
2025
2026
Citations per year (5y)
100total
20222023202420252026

Selected Papers

15
1
Review|54 citations·2019
Methods Used to Assess the 3D Accuracy of Dental Implant Positions in Computer-Guided Implant Placement: A Review
Se-Wook Pyo, Young‐Jun Lim, Ki‐Tae Koo, Jungwon Lee
SJR Q1Journal of Clinical MedicineOA

The purpose of this review is to examine various assessment methods in order to compare the accuracy between the virtually planned and clinically achieved implant positions. In this review, comparison methods using pre- and post-operative computed topography (CT) data and digital impressions for definitive prosthesis will be described. The method for the displacement and strain for quantification of the error will also be explored. The difference between the planned and the actual implant placem

Oral SurgeryDentistry
2
Article|43 citations·2013
Photofunctionalization Enhances Bone-Implant Contact, Dynamics of Interfacial Osteogenesis, Marginal Bone Seal, and Removal Torque Value of Implants
Se-Wook Pyo, Young‐Bum Park, Hong‐Seok Moon, Jae Hoon Lee, Takahiro Ogawa
Implant DentistryOA

Photofunctionalization enhanced the morphology, quality, and behavior of periimplant osteogenesis, including the increased BIC, expedited robust interfacial bone deposition, and improved marginal bone seal and support.

Oral SurgeryDentistry
3
Article|33 citations·2020
Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: anin vitrostudy
Jungwon Lee, Se-Wook Pyo, Hyun‐Jae Cho, Jung‐Sub An, Jae‐Hyun Lee, Ki‐Tae Koo, Yong‐Moo Lee
SJR Q1Journal of Periodontal & Implant ScienceOA

Purpose: A stability-measuring device that utilizes damping capacity analysis (DCA) has recently been introduced in the field of dental implantology. This study aimed to evaluate the sensitivity and reliability of this device by measuring the implant stability of ex vivo samples in comparison with a resonance frequency analysis (RFA) device. Methods: Six implant beds were prepared in porcine ribs using 3 different drilling protocols to simulate various implant stability conditions. Thirty-six po

Oral SurgeryDentistry
4
Review|28 citations·2020
Ceramic Materials and Technologies Applied to Digital Works in Implant-Supported Restorative Dentistry
Se-Wook Pyo, Dae‐Joon Kim, Jung‐Suk Han, In‐Sung Yeo
SJR Q2MaterialsOA

Computer-aided design and manufacturing technology has been closely associated with implant-supported restoration. The digital system employed for prosthodontic restorations comprises data acquisition, processing, and manufacturing using subtractive or additive methods. As digital implantology has developed, optical scanning, computer-based digital algorithms, fabricating techniques, and numerical control skills have all rapidly improved in terms of their accuracy, which has resulted in the deve

OrthodonticsDentistry
5
Review|26 citations·2023
Advancements in Methods of Classification and Measurement Used to Assess Tooth Mobility: A Narrative Review
Gi Youn Kim, Sunjai Kim, Jae‐Seung Chang, Se-Wook Pyo
SJR Q1Journal of Clinical MedicineOA

Evaluating tooth mobility is clinically significant, not only for diagnosing periodontal tissues but also in determining the overall periodontal treatment plan. Numerous studies related to tooth mobility have been conducted over the years, including the proposal of various classifications as well as the development of electronic devices for objective measurement. However, there is still no consensus on the measurement methods and criteria for assessing tooth mobility. In this study, we provide a

Oral SurgeryDentistry
6
Article|19 citations·2023
Impact of profile angle of CAD-CAM abutment on the marginal bone loss of implant-supported single-tooth posterior restorations
Jin-Won Han, Jin-Woo Han, Se-Wook Pyo, Sunjai Kim
SJR Q1Journal of Prosthetic Dentistry
Oral SurgeryDentistry
7
Article|18 citations·2023
Comparison of the clinical outcomes of resin-modified glass ionomer and self-adhesive resin cementations for full-coverage zirconia restorations
Se-Wook Pyo, Koungjin Park, René Daher, Ho‐Beom Kwon, Jungsuk Han, Jae‐Hyun Lee
SJR Q1Journal of DentistryOA
OrthodonticsDentistry
8
Article|10 citations·2024
Comparative Analysis of Bone Regeneration According to Particle Type and Barrier Membrane for Octacalcium Phosphate Grafted into Rabbit Calvarial Defects
Se-Wook Pyo, Jeong‐Won Paik, Dana Lee, Young-Wook Seo, Jin‐Young Park, Sunjai Kim, Seong‐Ho Choi
SJR Q2BioengineeringOA

This animal study was aimed to evaluate the efficacy of new bone formation and volume maintenance according to the particle type and the collagen membrane function for grafted octacalcium phosphate (OCP) in rabbit calvarial defects. The synthetic bone substitutes were prepared in powder form with 90% OCP and granular form with 76% OCP, respectively. The calvarial defects were divided into four groups according to the particle type and the membrane application. All specimens were acquired 2 weeks

Biomedical EngineeringEngineering
9
Article|9 citations·2021
Reliability Verification of Damping Capacity Assessment Through In Vitro Analysis of Implant Micromotion in Peri-implant Bone Loss Model
Se-Wook Pyo, Hyung Keun Kim, Ohyung Kwon, Otgonbold Jamiyandorj, Keun‐Woo Lee
SJR Q2The International Journal of Oral & Maxillofacial Implants

Within the limitations of this in vitro study, the implant stability measured by a damping capacity assessment was suitable for investigating the extent of implant micromotions, which were determined by 0.5-mm horizontal changes in the peri-implant bone level.

Oral SurgeryDentistry
10
Article|6 citations·2019
A noninvasive esthetic treatment of isolated microdontia using new high-translucent cubic-phase zirconia (5Y-PSZ) laminate veneers: A case report
Min-Zin Ahn, Do-Gwan Ahn, Se-Wook Pyo, Hee‐Kyung Kim
The Journal of Korean Academy of ProsthodonticsOA
OrthodonticsDentistry
11
Review|6 citations·2024
Clinical performance of implant-assisted removable partial dentures using implant surveyed crowns: a systematic review and meta-analysis
So-Yeun Kim, Young-Eun Cho, Seoung‐Jin Hong, Jung‐Bo Huh, Se-Wook Pyo, Yuseung Yi, Soo-Yeon Yoo
SJR Q1The Journal of Advanced ProsthodonticsOA

According to the findings of this systematic review, ICRPD has a reasonable survival/success rate, minimal bone loss, and high patient satisfaction.

Oral SurgeryDentistry
12
Article|6 citations·2023
Digital mounting accuracy of 2 intraoral scanners with a single anterior or bilateral posterior occlusal scan: A three-dimensional analysis
Cheol-Ho Cha, Se-Wook Pyo, Jae‐Seung Chang, Sunjai Kim
SJR Q1Journal of Prosthetic Dentistry
OrthodonticsDentistry
13
Article|5 citations·2023
Up to a 15-Year Survival Rate and Marginal Bone Resorption of 1780 Implants with or without Microthreads: A Multi Center Retrospective Study
Ji‐Hwan Oh, Se-Wook Pyo, Jae‐Seung Chang, Sunjai Kim
SJR Q1Journal of Clinical MedicineOA

The effect of microthreads at the implant neck on the amount of marginal bone resorption is controversial. This multicenter retrospective study compared the implant survival rate and amount of marginal bone resorption between two platform-switching internal connection implant systems with or without microthreads. Patient-related (age and sex), surgery-related (implant installation site, type, diameter, and length), and prosthesis-related (prosthesis type) data were collected from patient charts

Oral SurgeryDentistry
14
Article|4 citations·2011
Maxillary anterior all ceramic restoration using digital impression and CAD/CAM
Se-Wook Pyo, Young‐Bum Park, Jee‐Hwan Kim, Hong‐Seok Moon, Keun‐Woo Lee
The Journal of Korean Academy of ProsthodonticsOA

The digital impression technique has been developed for more precise restorations and convenient procedures in prosthodontic treatment compared to the conventional impression technique. Along with the utilization of CAD/CAM, the introduction of digital impression technique actualizes the digitalization of dental treatments. This case is to compare two different prostheses introducing each procedure in detail; one from CAD/CAM after taking digital impression and the other from the conventional te

OrthodonticsDentistry
15
Article|4 citations·2017
Study on application to the field of dentistry using optical coherence tomography (OCT)
Se-Wook Pyo, Young‐Jun Lim, Won‐Jin Lee, Jun-Jae Lee
The Journal of Korean Academy of ProsthodonticsOA

목적: 본 논문은 다양한 의료분야 진단에 사용되고 있는 비침습적 영상진단장치 중 낮은 투과 깊이를 가지지만 우수한 분해능과 실시간 영상획득이 가능한 광간섭 단층영상기기(OCT)의 기본 작동 원리, 종류, 장단점 및 응용분야 등을 소개한다. 재료 및 방법: 본 논문에 사용된 연구 데이터는 PubMed, 의료저널 및 관련논...

Biomedical EngineeringEngineering

Research Areas

Oral SurgeryOrthodonticsBiomedical Engineering

Sewook Pyoの研究をNubintでさらに深く

この研究室の論文をアプリで開き、AIと共に読み、要約し、引用しましょう。