Shin Hye CHUNG
Seoul National University · 歯学
研究室紹介
Professor Shin Hye Chung's research lab specializes in biomaterials and oral implantology, focusing on the development and evaluation of advanced implant materials and surface modifications to enhance osseointegration and clinical performance. Key research directions include the synthesis and characterization of doped hydroxyapatite for improved osteoconductivity, the optimization of 3D printing technologies for dental restorations, and the biomechanical and biological evaluation of implant surfaces—particularly titanium-zirconium oxide coatings and surface topographies—under functional loading. The lab integrates computational modeling, in vivo animal studies, and clinical imaging to advance precision dentistry and implant design.
Research Overview
Research Output Trend
Figures are computed from collected data and may differ slightly.
Selected Papers
15With the advent of 3D printing technologies in dentistry, the optimization of printing conditions has been of great interest, so this study analyzed the accuracy of 3D-printed temporary restorations of different sizes produced by digital light processing (DLP) and liquid crystal display (LCD) printers. Temporary restorations of 2-unit, 3-unit, 5-unit, 6-unit, and full-arch cases were designed and printed from a DLP printer using NextDent C&B or an LCD printer using Mazic D Temp (n = 10 each)
The purpose of this study was to evaluate the geometry and surface characteristics of osseointegration after functional loading by radiographic, periodontal and histomorphometric analyses. We analysed three groups of implants with different geometry and surface characteristics using experimental dogs. The control group received Brånemark implants (group 1). Group 2 and group 3 implants each had a 0.5-mm pitch height but differed in surface characteristics. Group 2 implants were machine surfaced
AIM: The aim of this study was to evaluate and compare the osseointegration in rabbit tibiae of smooth and roughened powder injection moulded (PIM) zirconia implants with or without (Ti,Zr)O2 surface coatings. MATERIAL AND METHODS: Twenty-five rabbits received four types of external hex implants with identical geometry on the tibiae: PIM zirconia implants, roughened PIM zirconia implants, (Ti,Zr)O2 -coated PIM zirconia implants and (Ti,Zr)O2 -coated roughened PIM zirconia implants. The surface c
The root of the maxillary central incisor teeth tended to be positioning labially in the alveolar bony housing. The result of the CT analysis confirms the clinical guideline as a dependable clinical reference in immediate implant placement.
The present report presents a case of dens invaginatus (DI) in a patient with 4 maxillary incisors. A 24-year-old female complained of swelling of the maxillary left anterior region and discoloration of the maxillary left anterior tooth. The maxillary left lateral incisor (tooth #22) showed pulp necrosis and a chronic apical abscess, and a periapical X-ray demonstrated DI on bilateral maxillary central and lateral incisors. All teeth responded to a vitality test, except tooth #22. The anatomic f
OBJECTIVE: To compare the antimicrobial and physical properties of experimental primers containing chlorhexidine (CHX) or ursolic acid (UA) with a commercial primer. MATERIALS AND METHODS: Two antibacterial agents, 3 mg each of CHX and UA were incorporated respectively into 1 ml of Transbond XT primer (TX) to form antibacterial primers, TX-CHX and TX-UA. The antimicrobial activity of the three primers (TX, TX-CHX, and TX-UA) against Streptococcus mutans in both planktonic and biofilm phases was
The aim of this study was to evaluate the long term stability of shear bond strength (SBS) when 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) containing universal adhesive was used in the ceramic bracket bonding on dental zirconia. Twenty human maxillary incisors were collected. The ceramic bracket was bonded on the buccal enamel surface after the acid-etching and orthodontic primer application (Group CON). Sixty zirconia specimens were sintered, sandblasted and divided into three experi
BACKGROUND: A Case Difficulty Assessment Form was designed for use in endodontic curricula, and to assist practitioners with treatment planning, referral and recording. The aim of this study was to determine how endodontic case difficulty factors influence the operating time of single-visit nonsurgical endodontic treatments under general anesthesia. METHODS: Data on 198 single-visit endodontic treatments (80 anterior teeth, 43 premolars, and 75 molars) performed under general anesthesia by a spe
BACKGROUND: Safety issues for dental restorative composites are critical to material selection, but, limited information is available to dental practitioners. This study aimed to compare the chemical and biological characteristics of three nanohybrid dental composites by assessing filler particle analysis, monomer degree of conversion (DC), the composition of eluates, and cytotoxicity and reactive oxygen species (ROS) production in fibroblasts. METHODS: Three nanohybrid composites (TN, Tetric N-
Serum HE4 levels may not only allow for the detection of ovarian cancer, but also allow for better differentiation of cases of ovarian cancer versus other benign ovarian tumors compared with serum CA-125.
The purpose of this study is to evaluate the shear bond strength (SBS) of a primer-treated ceramic bracket on dental zirconia and to compare it with conventional ceramic bracket bonding on surface-treated zirconia. Sintered and finished dental zirconia was sandblasted. Samples were divided according to the treated surfaces: no treatment (X), ceramic primer on zirconia (Z), ceramic primer on bracket base (B), and ceramic primer on both zirconia and bracket base (ZB). The ceramic bracket was bonde