Yun-Sik Jeon
Ewha Womans University
研究室紹介
Professor Yun-Sik Jeon's research lab specializes in computational orthodontic biomechanics, focusing on the three-dimensional analysis of tooth movement and stress distribution using finite element modeling. The lab investigates the center of resistance in dental arches, the effects of alveolar bone loss on orthodontic force delivery, and the biomechanical efficiency of various orthodontic appliances—particularly those incorporating temporary anchorage devices (TADs) and mini-implants. Their work emphasizes clinical applications through patient-specific 3D modeling and simulation to optimize treatment planning and minimize adverse effects such as root resorption or anchorage loss.
Research Overview
Research Output Trend
Figures are computed from collected data and may differ slightly.
Selected Papers
15최근 골내 고정 형태의 temporary anchorage device (TAD)를 많이 이용하게 되면서 다양한 위치로부터 그리고 강한 교정력을 이용할 수 있게 되었다. 이에 따라 치아군의 이동양상을 예측하고 치료계획을 세우기 위하여 다양한 치아군의 저항중심의 위치에 대한 이해가 필요하게 되었다. 본 연구에서는 3차원 유한요소해석을 이용하여 상악 4전치, 6전치 그리고 상악 전치열에서 3차원적 저항중심의 위치를 조사하고자 하였다. 이를 위하여 상악 전치열 14개 치아와 치근막 및 치조골의 3차원 유한요소모델을 제작하였고, 각 치아군별로 치관부를 협측, 설측 호선, 설측 splint wire로 고정하여 개별 치아이동을 최소화하고 적용된 힘이 치아에 고루 분산되도록 하였다. 상악 중절치 절단연의 중점에서 연장된 와이어 빔에 수직, 수평으로 100 g 또는 200 g의 힘을 가하여 치아의 변위를 해석하고, 각 치아군에 속한 치아들이 최대한 평행이동 되는 힘의 적용부위를 저항중심으로 정의하
Objective: The purpose of this study was to observe stress distribution and displacement patterns of the entire maxillary arch with regard to distalizing force vectors applied from interdental miniscrews. Methods: A standard three-dimensional finite element model was constructed to simulate the maxillary teeth, periodontal ligament, and alveolar process. The displacement of each tooth was calculated on x, y, and z axes, and the von Mises stress distribution was visualized using color-coded scale
Objective: The aim of this study was to investigate the three-dimensional (3D) position of the center of resistance of 4 mandibular anterior teeth, 6 mandibular anterior teeth, and the complete mandibular dentition by using 3D finite-element analysis. Methods: Finite-element models included the complete mandibular dentition, periodontal ligament, and alveolar bone. The crowns of teeth in each group were fixed with buccal and lingual arch wires and lingual splint wires to minimize individual toot
본 연구의 목적은 pendulum 장치, 미니임플란트를 동반한 pendulum장치(펜듈럼), 오픈코일 스프링 및 미니임플란트를 동반한 오픈코일 스프링 이용 시 각각의 치아이동 양상을 3차원적으로 분석하는 데 있었다. 상악 좌측 치조골 및 치아 모형을 제작하고, Calorific machineⓇ을 이용하여 모형상에서 대구치를 3 mm 원심이동시켰다. 실험은 5회씩 반복 실시하였다. 모델을 전산화 단층 촬영한 후 V-WorksTM를 이용하여 3차원 모델을 제작하였다. RapidformTM상에서 3차원적으로 이동방향과 이동량을 계측하였고, 각각의 장치에 관한 통계적 유의성을 검정하였다. 교정용 미니임플란트를 간접 골성 고정원으로 이용하여 오픈코일 스프링으로 구치부를 원심으로 이동시켰을 때가 치체이동에 가장 가까운 이동양상을 보였고, 고정원 소실도 적게 나타났다 (p < 0.05). 오픈코일 스프링, 펜듈럼 장치 모두 미니임플란트를 부가적으로 이용했을 때 고정원 소실량이 적었다 (p < 0
효과적인 교정치료계획의 수립을 위하여 치열군의 저항중심의 위치에 대한 평가는 필수적이다. 이번 연구의 목적은 상악 치열군(4전치, 6전치, 14치아)에서 치조골 손실에 따른 저항중심의 위치변화를 조사해보고자 하였다. 상악 전치열 14개 치아와 치주인대 및 0 mm, 2 mm, 4 mm 손실된 치조골의 3차원 유한요소 모델을 제작하였고 각 치아군(4전치, 6전치, 14치아)별로 치관부를 협측, 설측호선 및 splint wire로 고정하여 치아군 모델을 제작한 후 상악 중절치의 절단연 중점에서 연장된 splint wire에 4전치와 6전치군에는 200 g, 14치아군에는 400 g의 후방 견인력과 압하력을 적용하여 저항중심의 수직적, 수평적 위치를 분석하였다. 4전치군에서 저항중심의 수직 위치는 치조골 0 mm, 2 mm, 4 mm 손실에 따라 중절치의 절단연에서 치근방향 13.5 mm, 14.5 mm, 15 mm, 수평 위치는 후방 12 mm, 12 mm, 12.5 mm, 6전치군에서
PURPOSE. The purpose of this study was to propose finite element (FE) modeling methods for predicting stress distributions on teeth and mandible under chewing action. MATERIALS AND METHODS. For FE model generation, CT images of skull were translated into 3D FE models, and static analysis was performed considering linear material behaviors and nonlinear geometrical effect. To find out proper boundary and loading conditions, parametric studies were performed with various areas and directions of re
교정용 미니 임플랜트의 식립 부위에 대한 연구는 주로 구치부 치근사이 공간에 집중되어 왔다. 본 연구의 목적은 전치에서 구치에 이르는 치아간의 피질골 두께와 치근간 거리를 측정함으로써 교정용 미니 임플랜트 식립 시에 참고할 수 있는 임상적 지침을 제공하는 것이다. 연구를 위해 성인 28명(남자 14명, 여자 14명)의 CT를 V-works 4.0TM을 이용하여 3차원 영상으로 전환하였다. 중절치에서 제2대구치에 이르는 모든 치아 사이를 치간 접촉점을 지나면서 교합 평면에 수직이 되도록 잘라 90° 단면을 형성한 후 치조정으로부터 높이를 달리하여 0, 15, 30, 45°의 각도를 주어 피질골의 두께를 측정하였다. 또한 치조정으로부터 2, 4, 6 mm 높이에서 교합 평면에 평행하게 잘라 90° 단면을 만든 후 치근간 거리를 측정하였다. 피질골의 두께는 전치부에서 구치부로 갈수록 두꺼워지는 경향을 보였으며, 5-6과 1-1 사이, 6-7과 1-1, 1-2, 2-3 사이에서는 유의한 차
Objective: This study compared occlusal contact areas of ideally planned set-up and accomplished final models against the initial in class I and II molar relationships at finishing. Methods: Evaluations were performed for 41 post-orthodontic treatment cases, of which 22 were clinically diagnosed as class I and the remainder were diagnosed as full cusp class II. Class I cases had four first premolars extracted, while class II cases had maxillary first premolars extracted. Occlusal contact areas w
Objective: To evaluate the factors that affect torque control during anterior retraction when utilizing the C-retractor with a palatal miniplate as an exclusive source of anchorage without posterior appliances. Methods: The C-retractor was modeled using a 3-dimensional beam element (0.9-mm-diameter stainless-steel wire) attached to mesh bonding pads. Various vertical heights and 2 attachment positions for the lingual anterior retraction hooks (LARHs) were evaluated. A force of 200 g was applied
Objective: The aims of this study were to use a 3-dimensional (3D) system to compare molar relationship assessments performed from the buccal and lingual aspects, and to measure differences in occlusal contact areas between Class II and Class I molar relationships. Methods: Study casts (232 pairs from 232 subjects, yielding a total of 380 sides) were evaluated from both the buccal and lingual aspects, so that molar relationships could be classified according to the scheme devised by Liu and Mels
Objective: The purpose of this study was to investigate the stress distribution on the orthodontic mini-implant (OMI) surface and periodontal ligament of the maxillary first and second molars as well as the tooth displacement according to the OMI position in the dragon helix appliance during scissors-bite correction. Methods: OMIs were placed at two maxillary positions, between the first and the second premolars (group 1) and between the second premolar and the first molar (group 2). The stress
교정용 미니스크류를 이용하여 하악 전치의 함입이 가능하다고 알려져 있으나 분절의 크기에 따른 예측가능한 이동 양상에 대하여 보고된 바는 미미하다. 본 연구에서는 하악 4전치와 6전치 분절 모델에서 미니스크류와 훅의 위치를 달리하여 함입력을 적용하였을 때 응력분포와 초기 변위 양상을 분석하고자 하악 전치와 치주인대, 치조골에 대한 3차원 유한요소 모델을 제작하여 미니스크류 및 호선상 훅의 위치에 의해 결정되는 힘 벡터에 따른 치아의 3차원 각 평면에서의 변위량 및 von Mises 응력분포 양상을 비교하였다. 하악 4전치 분절에서는 함입력의 위치에 무관하게 공히 치관의 전방 경사가 발생하였으며 측절치 원심의 미니스크류와 후하방 힘을 가한 경우 경사 정도가 최소인 것으로 나타났다. 6전치 분절의 함입 시 견치 전방에 위치한 미니스크류에 의해 역시 상당한 치관의 전방 경사 및 순측 치경부 치근막에 von Mises stress가 집중되었으며 견치 후방에 위치한 미니스크류와 중절치-측절치
The methods for the occlusal force measurement have long been developed. The occlusal analyzing equipment utilizing the pressure-sensitive film (Prescale) is useful for the assessment and comparison among large group of patients. On the other hand, the apparatus which uses the grid-based sensor sheet (T-scan) can be a useful assistant for acquiring the well-balanced occlusion. The device that can process the electrical input from the strain gauge which is attached to the tooth surface can collec
Objective: Teeth discoloration is a rare orthodontic complication. The aim of this study was to report the clinical progression of discoloration during orthodontic treatment. Methods: Discolored teeth, detected during orthodontic treatment between January 2003 and December 2012 by a single dentist using similar techniques and appliances, were analyzed. Results: The total number of teeth that showed discoloration was 28. Progression of discoloration was evaluated in only 24 teeth that were observ
본 연구에서는 NiTi scissors-bite corrector를 세 가지 서로 다른 굵기 0.018" × 0.025", 0.016" × 0.022", 0.016" 의 NiTi 와이어로 제작하였을 때 각각의 치아 이동 양상을 치아 이동 시뮬레이션 장치인 Calorific machine을 이용하여 3차원적으로 분석하고자 하였다. 가위교합에 이환된 상악 제2대구치 모형을 제작하고 제2소구치와 제1대구치 사이에 교정용 미니 임플랜트(orthodontic mini-implant)를 식립하여 제1대구치에 간접골성고정원을 설계하였다. 세 가지 굵기의 NiTi scissors-bite corrector를 부착하여 실험하였다. 치아의 이동 전후에 실험 모형은 computed tomography (CT)로 촬영하고 3차원 데이터로 변환하여 중첩하였다. 치아 이동 방향과 이동량을 계측하여, NiTi scissors-bite corrector 와이어 굵기에 따른 치아 이동 양상에 관한 통계적 유의성을