송시몬 교수
Simon Song
한양대학교 기계공학부 · 공학
연구실 소개
송시몬 교수 연구실은 마이크로플루이디크스와 나노소재를 기반으로 한 혁신적인 센서 및 분석 기술을 개발하고 있습니다. 특히, 레이저 패터닝을 활용한 나노다공성 막 제작, 온도 및 기체 감지에 적합한 유연한 고감도 센서, 그리고 종이 기반 마이크로플루이드릭스를 통한 정밀한 유량 제어 기술을 핵심 연구 분야로 삼고 있습니다. 이들 기술은 생물학적 샘플의 농축, 진단 센서, 환경 모니터링 등 다양한 의료 및 환경 응용 분야에 기여하고 있습니다.
연구 현황
연구 성과 추이
표시된 성과는 수집된 데이터 기준으로 산출되며, 일부 차이가 있을 수 있습니다.
주요 논문
15Laser-patterning of nanoporous membranes at the junction of a cross channel in a microchip is used to integrate protein concentration with an electrokinetic injection scheme. Upon application of voltage, linear electrophoretic concentration of charged proteins is achieved at the membrane surface because buffer ions can easily pass through the membrane while proteins larger than the molecular weight cutoff of the membrane (>5700) are retained. Simple buffer systems can be used, and the concentrat
A new, microfluidic temperature sensor system, based on a thermoresponsive conjugated polymer supramolecule, has been developed. By generating blue-phase polydiacetylene (PDA) sensor droplets using hydrodynamic instability, we were able to monitor the variation of fluorescent intensity of the droplets with respect to the flow temperature.
Chip-level integration of microdialysis membranes is described using a novel method for in situ photopatterning of porous polymer features. Rapid and inexpensive fabrication of nanoporous microdialysis membranes in microchips is achieved using a phase separation polymerization technique with a shaped UV laser beam. By controlling the phase separation process, the molecular weight cutoffs of the membranes can be engineered for different applications. Counterflow dialysis is used to demonstrate ex
A highly sensitive, tunable, flexible and microfluidic compatible gas sensor was developed based on a photochromic spiropyran-embedded PDMS composite.
Paper-based microfluidic devices have recently attracted attention for their ability to utilize the inherent capillary force, or absorptivity, of paper to generate flows instead of requiring an external force. This allows for a simple sensor system that can be readily manufactured at low costs; however, sophisticated flow control is still necessary to implement and analyze diverse functions. In this paper, we propose a facile flow rate control method by varying the permeability of chromatography
Droplet control through the use of light-induced thermocapillary effects has recently garnered attention due to its non-intrusive and multifunctional nature. An important issue in droplet control is the estimation of the thermocapillary force. The purpose of the present study is to estimate the thermocapillary force and propose empirical equations between the force and simply measurable key parameters such as droplet diameter and power of heat source. In addition, we aim to shift the droplet tra
A new, microfluidic polydiacetylene (PDA) sensor system based on the hydrodynamic focusing principle is developed. Narrow fluorescent bands are observed when the focused stream of a PDA solution contacts the sheath flows of cyclodextrin (CD) receptor molecules (see figure). The system allows for continuous and rapid monitoring of molecular recognition events.
Rational design of a hydrocarbon sensor that enables visual differentiation of saturated aliphatic hydrocarbons (SAHCs) is very difficult owing to the lack of useful functional groups that can interact with the sensor system. Here, we report a microbead embedded with polydiacetylene that undergoes faster swelling and faster blue-to-red color change in response to the hydrocarbons of shorter alkyl chains. Accordingly, visual differentiation among n-pentane, n-heptane, n-nonane, and n-undecane was
A microfluidic technique was employed to fabricate polydiacetylene (PDA)-embedded hydrogel microfibers. By taking advantage of calcium ion-induced insoluble hydrogel formation, supramolecularly assembled diacetylene (DA)-surfactant complexes were successfully immobilized in the calcium alginate fibers. Thus, instantaneous microfiber formation was observed when the core flow of DA supramolecules-containing alginate solution met the sheath flow of calcium ions. UV irradiation of the resulting fibe
The viscosity of biofluids can be used to acquire meaningful medical information on the conditions of a patient but has seldom been utilized in clinical practices owing to cumbersome measurement procedures and the need for large sample volumes. We present a colorimetric method to measure the viscosity of blood plasma using a paper-based viscometer developed in this study specifically for clinical diagnosis. The proposed analytical device consists of multilayered papers with fluid-loading, -mixin
Polymerizable supramolecular monomer vesicles are readily fabricated by employing a hydrodynamic focusing method on a microfluidic chip. The polymerized diacetylenene nanovesicles, generated using the microfluidic method, display an improved fluorescence property compared to those prepared by employing a conventional bulk method. The flexibility of the vesicle size control by manipulating the flow conditions is another significant feature of the new microfluidic approach.
대표 연구 분야
송시몬 교수의 연구를 Nubint에서 더 깊이 살펴보세요
이 연구실의 논문을 앱에서 열어 AI와 함께 읽고, 핵심을 요약하고, 내 글에 인용하세요.