송성은 교수
Sung-yeon Song
고려대학교 영상의학과 · 의학
연구실 소개
송성은 교수의 연구실은 유방암의 정밀 진단을 위한 다중모odal 영상 기반 기술 개발에 주력하고 있습니다. 특히 MRI를 활용한 컴퓨터 지원 진단(CAD), 방사선 영상 특성과 유전자형 간의 연관성 분석, 그리고 다중영상 융합 및 방사선형 특징(radiomics)을 통한 전임상 예측 모델 개발이 핵심 연구 방향입니다. 이는 유방암의 조기 진단 및 개인화된 치료 전략 수립에 기여하고자 합니다.
연구 현황
연구 성과 추이
표시된 성과는 수집된 데이터 기준으로 산출되며, 일부 차이가 있을 수 있습니다.
주요 논문
15BACKGROUND: We aimed to investigate the efficacy of computer-aided detection (CAD) for MRI in the assessment of tumor extent, lymph node status, and multifocality in invasive breast cancers in comparison with other breast imaging modalities. METHODS: Two radiologists measured the maximum tumor size, as well as, analyzed lymph node status and multifocality in 86 patients with invasive breast cancers using mammography, ultrasound, CT, MRI with and without CAD, and 18-fludeoxyglucose positron emiss
BACKGROUND: As both intravoxel incoherent motion (IVIM) modeling and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) provide perfusion parameters, IVIM-derived perfusion parameters might be expected to correlate with the kinetic features from DCE-MRI. PURPOSE: To investigate the association between IVIM parameters and prognostic factors and to evaluate the correlation between IVIM parameters and kinetic features in invasive breast cancer patients using computer-aided diagnosis (CA
BACKGROUND: In diffusion-weighted imaging (DWI) of breast MRI, simultaneous multislice acceleration techniques can be used for readout-segmented echo planar imaging (rs-EPI) to shorten the scan time. PURPOSE: To compare the image quality, apparent diffusion coefficient (ADC) value, and scan time of rs-EPI and simultaneous multislice rs-EPI (SMS rs-EPI) sequences. STUDY TYPE: Retrospective. SUBJECTS: In all, 134 consecutive women (mean age: 55.3 years) with invasive breast cancer who underwent pr
At supplemental screening breast US, close attention should be paid to the presence of a margin that is not circumscribed, and multiple lesions should be separately assessed to reduce the number of missed breast cancers.
A predictive model incorporating breast MRI-derived multiparametric and radiomic features may be valuable in predicting ALNM preoperatively in patients with TNBC.
Background Human epidermal growth factor receptor 2-positive (HER2+) breast cancer has two distinct subtypes according to hormone receptor (HR) status. Survival, pattern of recurrence, and treatment response differ between HR-/HER2+ and HR+/HER2+ cancers. Purpose To investigate imaging and clinicopathologic features of HER2+ cancers and their correlation with HR expression. Material and Methods Between 2011 and 2013, 252 consecutive patients with 252 surgically confirmed HER2+ cancers (125 HR- a
We recommend the CH area ratio of an axillary lymph node on ultrasound as a quantitative indicator for the classification of lymph nodes. The CH area ratio can improve diagnostic performance when compared with the LT axis ratio or blood flow pattern.
Of the CAD-assessed kinetic features, higher peak enhancement may correlate with higher histologic grade, and higher delayed-plateau component and angio-volume correlate with higher Ki-67 index. These results support the clinical application of kinetic features in prognosis assessment.
Background Supplemental breast ultrasonography (US) has been used as a surveillance imaging method in women with personal history of breast cancer (PHBC). However, there have been limited data regarding diagnostic performances. Purpose To evaluate diagnostic performances of supplemental breast US screening for women with PHBC and to compare with those for women without PHBC. Material and Methods Between 2011 and 2012, 12,230 supplemental US exams were performed in 12,230 women with negative mamm
BACKGROUND: Computer-aided detection (CAD) can detect breast lesions by using an enhancement threshold. Threshold means the percentage of increased signal intensity in post-contrast imaging compared to precontrast imaging. If the pixel value of the enhanced tumor increases above the set threshold, CAD provides the size of the tumor, which is calculated differently depending on the set threshold. Therefore, CAD requires the accurate setting of thresholds. We aimed to compare the diagnostic accura
대표 연구 분야
송성은 교수의 연구를 Nubint에서 더 깊이 살펴보세요
이 연구실의 논문을 앱에서 열어 AI와 함께 읽고, 핵심을 요약하고, 내 글에 인용하세요.