Skip to main content
QUICK REVIEW

[Paper Review] A 1 mm Scintillating Fibre Tracker Readout by a Multi-anode Photomultiplier

B. Leverington, M. Anelli|arXiv (Cornell University)|Jun 28, 2011
Radiation Detection and Scintillator TechnologiesPhysics and Astronomy7 references9 citations
TL;DR

This paper presents a prototype 1 mm scintillating fibre tracker read out by a 64-channel Hamamatsu H8500 multi-anode photomultiplier (MA-PMT), demonstrating a spatial resolution of 0.118 mm (analog) and 0.119 mm (digital) for 4 layers of 0.7 mm square fibres. The study identifies crosstalk and channel mapping as critical factors, proposing optimized fibre-to-MA-PMT channel layouts to improve resolution and efficiency for future LHCb tracker upgrades.

ABSTRACT

This note describes a prototype particle tracking detector constructed with 1 mm plastic scintillating fibres with a 64 channel Hamamatsu H8500 flat-panel multi-anode photomultiplier readout. Cosmic ray tracks from an array of 11 gas-filled drift tubes were matched to signals in the scintillating fibres in order to measure the resolution and efficiency of tracks reconstructed in the fibre-based tracker. A GEANT4 detector simulation was also developed to compare cosmic ray data with MC results and is discussed in the note. Using the parameters measured in this experimental setup, modified fibre tracker designs are suggested to improve resolution and efficiency in future prototypes to meet modern detector specifications.

Motivation & Objective

  • To develop a high-granularity, radiation-hard particle tracker using 1 mm scintillating fibres for the LHCb detector upgrade.
  • To evaluate the spatial resolution and efficiency of a fibre tracker read out by a multi-anode photomultiplier (MA-PMT) under cosmic ray conditions.
  • To identify design improvements—such as fibre geometry, channel spacing, and MA-PMT mapping—that enhance position resolution and efficiency.
  • To compare experimental results with GEANT4 simulations to validate performance and guide future prototype designs.
  • To assess the feasibility of replacing gas-based straw tubes with fibre-based trackers in high-luminosity LHC environments.

Proposed method

  • A prototype tracker was constructed using 1 mm plastic scintillating fibres arranged in 4–6 layers with 1 mm or 0.7 mm horizontal spacing.
  • The tracker was read out using a Hamamatsu H8500 flat-panel MA-PMT with 64 channels, optimized for single photoelectron resolution.
  • Cosmic ray tracks were reconstructed by matching signals from the fibre tracker to those from an array of 11 gas-filled drift tubes.
  • A GEANT4-based Monte Carlo simulation was developed to model light yield, charge distribution, attenuation, and crosstalk effects.
  • Fibre tracker performance was evaluated through analysis of photoelectron yield, signal-to-noise ratio, crosstalk, and hit threshold settings.
  • Optimized fibre-to-MA-PMT channel mapping was proposed to minimize crosstalk and improve position resolution.

Experimental results

Research questions

  • RQ1What is the achievable spatial resolution of a 1 mm scintillating fibre tracker read out by a 64-channel MA-PMT under cosmic ray conditions?
  • RQ2How do fibre geometry (round vs. square), diameter, and channel spacing affect position resolution and efficiency?
  • RQ3To what extent does crosstalk in the MA-PMT and optical crosstalk between fibres degrade position resolution?
  • RQ4How does the choice of photodetector (e.g., H8500 vs. H7456) impact signal yield, noise, and overall tracker performance?
  • RQ5Can modified fibre tracker designs achieve sub-0.2 mm resolution while maintaining high efficiency and radiation hardness for LHCb upgrade applications?

Key findings

  • The 4-layer square 0.7 mm fibre design achieved a spatial resolution of 0.118 mm (analog) and 0.119 mm (digital) at 60 cm, meeting the target of <0.2 mm resolution.
  • The 6-layer round 0.7 mm fibre design achieved a resolution of 0.122 mm (digital) at 60 cm, showing improved performance over larger-diameter fibres.
  • Crosstalk between adjacent MA-PMT channels was identified as the dominant limiting factor in digital readout, reducing resolution by up to 20% if unmitigated.
  • A proposed fibre-to-MA-PMT channel mapping strategy, avoiding adjacent channel placement, significantly reduces crosstalk and improves resolution.
  • The H7456-100 MA-PMT, with 34% quantum efficiency and lower crosstalk, is shown to be superior to the H8500 for future tracker designs.
  • Efficiency exceeded 97% for the best-performing designs (e.g., 4sqr0.7mm) at 2.7 mm hit threshold, indicating high detection capability.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.