[Paper Review] A cardiac electromechanics model coupled with a lumped parameters model for closed-loop blood circulation. Part II: numerical approximation
This paper presents a novel implicit-explicit (IMEX) numerical scheme for coupling a 3D cardiac electromechanics model with a 0D lumped parameters model of blood circulation in a fully segregated, stable manner. The method enables accurate, scalable simulation of closed-loop circulation with robust reconstruction of the stress-free reference configuration via a projection-based algorithm, validated through grid convergence and clinically relevant hemodynamic scenarios including preload, afterload, and contractility variations.
In the framework of accurate and efficient segregated schemes for 3D cardiac electromechanics and 0D cardiovascular models, we propose here a novel numerical approach to address the coupled 3D-0D problem introduced in Part I of this two-part series of papers. We combine implicit-explicit schemes to solve the different cardiac models in a multiphysics setting. We properly separate and manage the different time and space scales related to cardiac electromechanics and blood circulation. We employ a flexible and scalable intergrid transfer operator that enables to interpolate Finite Element functions among different meshes and, possibly, among different Finite Element spaces. We propose a numerical method to couple the 3D electromechanical model and the 0D circulation model in a numerically stable manner within a fully segregated fashion. No adaptations are required through the different phases of the heartbeat. We also propose a robust algorithm to reconstruct the stress-free reference configuration. Due to the computational cost associated with the numerical solution of this inverse problem, the reference configuration recovery algorithm comes along with a novel projection technique to precisely recover the unloaded geometry from a coarser representation of the computational domain. We show the convergence property of our numerical schemes by performing an accuracy study through grid refinement. To prove the biophysical accuracy of our computational model, we also address different scenarios of clinical interest in our numerical simulations by varying preload, afterload and contractility. Indeed, we simulate physiologically relevant behaviors and we reproduce meaningful results in the context of cardiac function.
Motivation & Objective
- To develop a numerically stable, fully segregated numerical method for coupling 3D cardiac electromechanics with 0D lumped parameter models of blood circulation.
- To address the challenge of disparate time and space scales between cardiac mechanics and systemic circulation.
- To enable accurate simulation of physiologically relevant hemodynamic behaviors under varying preload, afterload, and contractility.
- To reconstruct the stress-free reference configuration of the heart efficiently using a projection technique on coarser meshes.
- To ensure robustness and scalability across different cardiac phases without requiring model adaptations.
Proposed method
- Employment of implicit-explicit (IMEX) time integration schemes to handle stiff and non-stiff components of the cardiac and circulatory models separately.
- Use of a flexible, scalable intergrid transfer operator to interpolate finite element functions across non-matching meshes and finite element spaces.
- Adoption of a segregated solution strategy that decouples the 3D electromechanical and 0D circulation models while preserving stability and accuracy.
- Development of a novel projection-based algorithm to recover the stress-free reference configuration from a coarser computational representation.
- Implementation of a robust algorithm for reconstructing the unloaded heart geometry without requiring iterative re-meshing or remapping.
- Use of grid refinement studies to verify the convergence properties of the numerical schemes.
Experimental results
Research questions
- RQ1How can a stable and accurate coupling be achieved between 3D cardiac electromechanics and 0D lumped parameter circulation models in a segregated framework?
- RQ2What numerical strategy ensures stability and accuracy when handling vastly different time and space scales in the coupled system?
- RQ3How can the stress-free reference configuration of the heart be reconstructed efficiently and accurately from a coarser mesh representation?
- RQ4Can the proposed method reproduce physiologically relevant hemodynamic responses under varying preload, afterload, and contractility?
- RQ5What is the convergence behavior of the numerical scheme under grid refinement?
Key findings
- The proposed IMEX scheme demonstrates optimal convergence rates in space and time, confirmed through systematic grid refinement studies.
- The intergrid transfer operator enables accurate and stable interpolation between non-matching meshes and finite element spaces.
- The stress-free reference configuration is reconstructed with high precision using the novel projection technique, significantly reducing computational cost.
- The model successfully reproduces physiologically realistic hemodynamic responses, including pressure-volume loops and ejection fraction changes, under varied preload, afterload, and contractility conditions.
- The fully segregated approach maintains stability and accuracy across all phases of the cardiac cycle without requiring model modifications.
- The method is computationally scalable and robust, suitable for patient-specific simulations with complex geometry and hemodynamics.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.