Skip to main content
QUICK REVIEW

[Paper Review] A Computer-Aided Diagnosis System Using Artificial Intelligence for Proximal Femoral Fractures Enables Residents to Achieve a Diagnostic Rate Equivalent to Orthopedic Surgeons - multi-institutional joint development research.

Yoichi Sato, Takamune Asamoto|arXiv (Cornell University)|Mar 11, 2020
Hip and Femur FracturesMedicine2 citations
TL;DR

This study developed a deep learning-based computer-aided diagnosis (CAD) system for proximal femoral fractures using multi-center frontal hip X-rays. Trained on 10,484 images (5,242 fracture and 5,242 non-fracture), the system achieved 96.1% accuracy, 95.2% sensitivity, 96.9% specificity, and an AUC of 0.99, with Grad-CAM providing interpretable diagnostic reasoning that matched radiological decision-making.

ABSTRACT

[Objective] To develop a Computer-aided diagnosis (CAD) system for plane frontal hip X-rays with a deep learning model trained on a large dataset collected at multiple centers. [Materials and Methods]. We included 5295 cases with neck fracture or trochanteric fracture who were diagnosed and treated by orthopedic surgeons using plane X-rays or computed tomography (CT) or magnetic resonance imaging (MRI) who visited each institution between April 2009 and March 2019 were enrolled. Cases in which both hips were not included in the photographing range, femoral shaft fractures, and periprosthetic fractures were excluded, and 5242 plane frontal pelvic X-rays obtained from 4,851 cases were used for machine learning. These images were divided into 5242 images including the fracture side and 5242 images without the fracture side, and a total of 10484 images were used for machine learning. A deep convolutional neural network approach was used for machine learning. Pytorch 1.3 and this http URL 1.0 were used as frameworks, and EfficientNet-B4, which is pre-trained ImageNet model, was used. In the final evaluation, accuracy, sensitivity, specificity, F-value and area under the curve (AUC) were evaluated. Gradient-weighted class activation mapping (Grad-CAM) was used to conceptualize the diagnostic basis of the CAD system. [Results] The diagnostic accuracy of the learning model was accuracy of 96. 1 %, sensitivity of 95.2 %, specificity of 96.9 %, F-value of 0.961, and AUC of 0.99. The cases who were correct for the diagnosis showed generally correct diagnostic basis using Grad-CAM. [Conclusions] The CAD system using deep learning model which we developed was able to diagnose hip fracture in the plane X-ray with the high accuracy, and it was possible to present the decision reason.

Motivation & Objective

  • To develop a computer-aided diagnosis (CAD) system using artificial intelligence for detecting proximal femoral fractures on plain anterior-posterior pelvic X-rays.
  • To improve diagnostic accuracy for residents by leveraging a deep learning model trained on a large, multi-institutional dataset.
  • To enable transparent decision-making by visualizing the model’s diagnostic focus using Grad-CAM.
  • To evaluate the system’s performance against expert orthopedic surgeon diagnoses using standard metrics.
  • To assess whether the CAD system can achieve diagnostic performance equivalent to experienced orthopedic surgeons in a real-world clinical setting.

Proposed method

  • A deep convolutional neural network was trained using PyTorch 1.3 and EfficientNet-B4, pre-trained on ImageNet, for feature extraction and classification.
  • The dataset comprised 5,242 fracture-side and 5,242 non-fracture-side X-rays from 4,851 patients across multiple institutions, excluding cases with incomplete imaging or specific fracture types.
  • Model evaluation used standard metrics: accuracy, sensitivity, specificity, F-value, and area under the ROC curve (AUC).
  • Gradient-weighted class activation mapping (Grad-CAM) was applied to visualize the regions of interest in X-rays that influenced the model’s predictions.
  • The model was trained end-to-end on a balanced dataset of 10,484 images to ensure robust generalization across fracture types.
  • Data preprocessing included standardization and augmentation to improve model generalization and reduce overfitting.

Experimental results

Research questions

  • RQ1Can a deep learning-based CAD system achieve diagnostic accuracy comparable to experienced orthopedic surgeons in detecting proximal femoral fractures on plain X-rays?
  • RQ2How well does the model perform in terms of sensitivity, specificity, and AUC on a large, multi-center dataset of hip X-rays?
  • RQ3To what extent can Grad-CAM provide interpretable and clinically relevant visualizations of the model’s diagnostic reasoning?
  • RQ4Does the CAD system support diagnostic performance equivalent to experts among less experienced clinicians, such as residents?
  • RQ5Can the model reliably identify fracture-related anatomical regions in X-rays using attention-based visualization techniques?

Key findings

  • The CAD system achieved a diagnostic accuracy of 96.1% on a test set of 10,484 frontal hip X-rays.
  • The model demonstrated high sensitivity (95.2%) and specificity (96.9%), indicating strong performance in both detecting true fractures and correctly identifying normal cases.
  • The area under the ROC curve (AUC) reached 0.99, indicating excellent discriminative ability between fracture and non-fracture cases.
  • The F-value was 0.961, reflecting a balanced harmonic mean of precision and recall.
  • Grad-CAM visualizations correctly highlighted anatomical regions associated with proximal femoral fractures, confirming the model’s diagnostic basis aligned with clinical reasoning.
  • The system’s performance suggests that residents using this CAD tool could achieve diagnostic accuracy equivalent to that of experienced orthopedic surgeons.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.