[Paper Review] Detecting hip fractures with radiologist-level performance using deep neural networks
A deep DenseNet-based CNN system analyzes frontal pelvic X-rays to detect hip fractures with radiologist-level performance, achieving an AUC of 0.994 on a large hold-out test set.
We developed an automated deep learning system to detect hip fractures from frontal pelvic x-rays, an important and common radiological task. Our system was trained on a decade of clinical x-rays (~53,000 studies) and can be applied to clinical data, automatically excluding inappropriate and technically unsatisfactory studies. We demonstrate diagnostic performance equivalent to a human radiologist and an area under the ROC curve of 0.994. Translated to clinical practice, such a system has the potential to increase the efficiency of diagnosis, reduce the need for expensive additional testing, expand access to expert level medical image interpretation, and improve overall patient outcomes.
Motivation & Objective
- Motivate automated, accurate hip fracture detection to reduce missed fractures and imaging costs.
- Leverage a large, real-world dataset to train a robust deep learning pipeline.
- Develop an end-to-end system that excludes inappropriate studies, localises the femoral neck, and detects fractures automatically.
Proposed method
- Use a DenseNet-172 CNN with 12 features per layer and 1.43M parameters.
- Train with primary fracture presence loss and secondary location loss (intra-capsular vs. extra-capsular).
- Apply extensive data augmentation and regularisation (dropout 0.2, weight decay 1e-5).
- Pre-process with three CNNs: CNN-frontal to identify frontal pelvis X-rays, CNN-bounding to localise the femoral neck, CNN-metal to exclude metal implants.
- Train with Adam optimizer (lr=1e-4), 25 epochs, batch size 14, on PyTorch hardware; ~22 hours total.
Experimental results
Research questions
- RQ1Can a deep learning model achieve radiologist-level accuracy on hip fracture detection from frontal pelvic X-rays?
- RQ2What is the performance (AUC, accuracy, precision, recall) of a fully automated pipeline compared to radiologist reports?
- RQ3How does automated localization of the femoral neck impact fracture detection performance?
- RQ4What is the effect of data heterogeneity and pre-processing on model efficacy?
Key findings
- The model achieves an ROC AUC of 0.994 on the hold-out test set.
- The automated system matches or exceeds human upper-bound performance under the study’s evaluation setup.
- High-precision and high-sensitivity operating points yield comparable performance to radiologist estimates across metrics.
- Pre-processing CNNs effectively filter inputs, localise the femoral neck, and remove cases with metal, enabling robust fracture detection.
- Compared with recent automated approaches, the DenseNet-based system shows superior accuracy and F1 on the same test conditions.