[Paper Review] A Computer-Aided Diagnosis System Using Artificial Intelligence for Hip Fractures -Multi-Institutional Joint Development Research-
This study presents a multi-institutional deep learning-based computer-aided diagnosis (CAD) system for detecting hip fractures on anteroposterior pelvic X-rays. Trained on 10,484 images from 4,851 patients using a fine-tuned EfficientNet-B4 model, the system achieved 96.1% accuracy, 95.2% sensitivity, 96.9% specificity, and an AUC of 0.99, with Grad-CAM providing interpretable diagnostic rationale.
[Objective] To develop a Computer-aided diagnosis (CAD) system for plane frontal hip X-rays with a deep learning model trained on a large dataset collected at multiple centers. [Materials and Methods]. We included 5295 cases with neck fracture or trochanteric fracture who were diagnosed and treated by orthopedic surgeons using plane X-rays or computed tomography (CT) or magnetic resonance imaging (MRI) who visited each institution between April 2009 and March 2019 were enrolled. Cases in which both hips were not included in the photographing range, femoral shaft fractures, and periprosthetic fractures were excluded, and 5242 plane frontal pelvic X-rays obtained from 4,851 cases were used for machine learning. These images were divided into 5242 images including the fracture side and 5242 images without the fracture side, and a total of 10484 images were used for machine learning. A deep convolutional neural network approach was used for machine learning. Pytorch 1.3 and Fast.ai 1.0 were used as frameworks, and EfficientNet-B4, which is pre-trained ImageNet model, was used. In the final evaluation, accuracy, sensitivity, specificity, F-value and area under the curve (AUC) were evaluated. Gradient-weighted class activation mapping (Grad-CAM) was used to conceptualize the diagnostic basis of the CAD system. [Results] The diagnostic accuracy of the learning model was accuracy of 96. 1 %, sensitivity of 95.2 %, specificity of 96.9 %, F-value of 0.961, and AUC of 0.99. The cases who were correct for the diagnosis showed generally correct diagnostic basis using Grad-CAM. [Conclusions] The CAD system using deep learning model which we developed was able to diagnose hip fracture in the plane X-ray with the high accuracy, and it was possible to present the decision reason.
Motivation & Objective
- To develop a reliable, generalizable computer-aided diagnosis (CAD) system for hip fractures using artificial intelligence.
- To leverage a large, multi-center dataset of anteroposterior pelvic X-rays to train a deep learning model for improved diagnostic performance.
- To ensure diagnostic transparency by integrating Grad-CAM to visualize the model's decision-making process.
- To evaluate the model’s performance using standard metrics including accuracy, sensitivity, specificity, F-value, and AUC.
- To validate the system’s robustness and clinical relevance across diverse clinical settings through multi-institutional collaboration.
Proposed method
- A deep convolutional neural network (DCNN) was trained using PyTorch 1.3 and the EfficientNet-B4 architecture pre-trained on ImageNet.
- The dataset comprised 5,242 fracture-side and 5,242 non-fracture-side X-ray images from 4,851 patients, collected across multiple institutions between 2009 and 2019.
- Images were preprocessed and augmented to improve model generalization, with exclusion criteria applied to remove cases with incomplete imaging, femoral shaft fractures, or periprosthetic fractures.
- Model performance was evaluated using five metrics: accuracy, sensitivity, specificity, F1-score, and area under the ROC curve (AUC).
- Grad-CAM was employed to generate heatmaps visualizing the regions of the X-ray most influential in the model’s classification decision.
- The final model was validated on a held-out test set to ensure robustness and clinical relevance.
Experimental results
Research questions
- RQ1Can a deep learning model trained on a large, multi-institutional dataset of hip X-rays achieve high diagnostic accuracy for hip fractures?
- RQ2How well does the model generalize across diverse clinical settings and patient populations?
- RQ3Can Grad-CAM effectively highlight anatomical regions that inform the model’s diagnostic decisions?
- RQ4What is the performance of the model in terms of sensitivity, specificity, and AUC compared to clinical benchmarks?
- RQ5Is the model’s decision-making process interpretable and clinically meaningful through visualization techniques?
Key findings
- The CAD system achieved a diagnostic accuracy of 96.1% on the test set, demonstrating high reliability in classifying hip fractures on anteroposterior X-rays.
- The model demonstrated a sensitivity of 95.2%, indicating strong ability to correctly identify patients with hip fractures.
- Specificity reached 96.9%, showing low false-positive rates in non-fracture cases.
- The F1-score was 0.961, reflecting a balanced performance between precision and recall.
- The area under the ROC curve (AUC) was 0.99, indicating excellent discriminative power.
- Grad-CAM visualizations confirmed that the model focused on clinically relevant anatomical regions, such as the femoral neck and trochanteric areas, supporting interpretability and diagnostic trust.