[Paper Review] A microwave paraphoton and axion detection experiment with 300 dB electromagnetic shielding at 3 GHz

M. Betz, F. Caspers|arXiv (Cornell University)|Jul 13, 2012
Dark Matter and Cosmic PhenomenaPhysics and Astronomy5 references5 citations
TL;DR

This paper presents a microwave-based experiment at CERN to detect paraphotons and axions via the 'light shining through the wall' (LSW) effect, employing a 300 dB electromagnetic shielding system and a vector signal analyzer with 24 μHz resolution bandwidth. No signal was observed, leading to improved exclusion limits for paraphotons at 2.9565 GHz, setting a new sensitivity threshold for hidden photon searches.

ABSTRACT

For the microwave equivalent of "light shining through the wall" (LSW) experiments, a sensitive microwave detector and very high electromagnetic shielding is required. The screening attenuation between the axion generating cavity and the nearby detection cavity should be greater than 300 dB, in order to improve over presently existing exclusion limits. To achieve these goals in practice, a "box in a box" concept was utilized for shielding the detection cavity, while a vector signal analyzer was used as a microwave receiver with a very narrow resolution bandwidth in the order of a few micro-Hz. This contribution will present the experimental layout and the results to date.

Motivation & Objective

  • To search for weakly interacting sub-eV particles (WISPs), including paraphotons and axions, via microwave-based light shining through the wall (LSW) experiments.
  • To improve upon existing exclusion limits for paraphotons by achieving >300 dB electromagnetic shielding between emitter and detector cavities.
  • To demonstrate a highly sensitive microwave detection system with sub-microhertz resolution bandwidth using a vector signal analyzer.
  • To validate the stability and sensitivity of the experimental setup over an 11.5-hour measurement run under stringent noise and frequency stability constraints.
  • To lay the groundwork for future axion searches by integrating a magnetic field into the setup.

Proposed method

  • A 'box in a box' electromagnetic shielding design was implemented to achieve >300 dB attenuation between the emitting and detecting microwave cavities.
  • Two identical silver-coated brass cavities (140 mm diameter, 120 mm height) were tuned to 2.9565 GHz and coupled via inductive loops for critical coupling to the TE011 mode.
  • A vector signal analyzer with a 20 Hz bandwidth and 24 μHz resolution was used to detect narrowband signals, with baseband downconversion and IQ digitization.
  • The system was phase-locked to a common 10 MHz reference to maintain frequency stability within the resolution bandwidth.
  • Welch’s method with 90% overlapping Hann-windowed segments was applied to 11.5-hour time traces to estimate the noise power spectrum and achieve a 24 μHz resolution bandwidth.
  • The noise temperature model included contributions from the cavity, low-noise amplifier (32.4 K), and reflected noise waves, with the resonant frequency tracked via spectral noise maxima.

Experimental results

Research questions

  • RQ1Can a microwave LSW experiment achieve >300 dB electromagnetic shielding to suppress background noise and isolate the detection cavity?
  • RQ2What is the minimum detectable power level achievable with a vector signal analyzer operating at 24 μHz resolution bandwidth in a high-sensitivity microwave setup?
  • RQ3Does the experimental system maintain frequency stability over an 11.5-hour measurement run, as required for narrowband signal detection?
  • RQ4Can the absence of a signal in the detection cavity be used to set a new exclusion limit for paraphotons at 2.9565 GHz?
  • RQ5What is the sensitivity of the system to kinetic mixing parameters χ for hidden photons, given the measured parameters and noise levels?

Key findings

  • No signal was detected in the 11.5-hour measurement run, leading to a new exclusion limit for paraphotons at 2.9565 GHz.
  • The minimum detectable power in the detection cavity was determined to be −211 dBm, corresponding to a sensitivity threshold for signal power.
  • The system achieved a resolution bandwidth of 24 μHz through Welch’s method on a 11.5-hour time trace, enabling detection of extremely narrow spectral lines.
  • The resonant frequency of the detection cavity remained stable within ±1.5 mHz over the measurement period, as confirmed by pre- and post-run noise power spectra.
  • The measured noise floor was consistent with theoretical expectations, with the maximum noise temperature occurring at the cavity’s resonant frequency.
  • The exclusion limit for the kinetic mixing parameter χ was improved compared to previous experiments, as shown in Figure 2, due to the high shielding and narrowband detection.