Skip to main content
QUICK REVIEW

[Paper Review] Dark Matter Axion Search Using a Josephson Traveling Wave Parametric Amplifier

C. Bartram, T. Braine|arXiv (Cornell University)|Oct 15, 2021
Dark Matter and Cosmic PhenomenaPhysics and Astronomy2 references13 citations
TL;DR

This paper presents the first use of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in a dark matter axion search, achieving a new exclusion bound for axion-like particles with couplings above $10^{-13}\ \text{GeV}^{-1}$ at a mass of 19.84 $\mu$eV. The JTWPA enabled high-gain, broadband amplification over a 3 GHz bandwidth, significantly advancing the potential for future wideband axion searches in experiments like ADMX.

ABSTRACT

We present a new exclusion bound of axion-like particle dark matter with axion-photon couplings above $\mathrm{10^{-13}}$ $\mathrm{GeV^{-1}}$ over the frequency range 4796.7--4799.5 MHz, corresponding to a narrow range of axion masses centered around 19.84 $μ$eV. This measurement represents the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in a dark matter search. The JTWPA was operated in the insert of the Axion Dark Matter eXperiment (ADMX) as part of an independent receiver chain that was attached to a 0.588-liter cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.

Motivation & Objective

  • To demonstrate the feasibility of using a Josephson Traveling Wave Parametric Amplifier (JTWPA) in a dark matter axion search experiment.
  • To achieve high-sensitivity detection of axion-like particles by leveraging the JTWPA's wide bandwidth and low noise performance.
  • To set a new exclusion bound for axion-photon coupling strength in the DFSZ model at a narrow mass range centered at 19.84 $\mu$eV.
  • To validate the resilience and operational stability of the JTWPA under real experimental conditions, including magnetic field disturbances.
  • To enable future broadband axion searches by demonstrating the JTWPA's potential for covering large regions of axion parameter space efficiently.

Proposed method

  • The JTWPA was integrated into the ADMX experiment as a standalone receiver chain, attached to a 0.588-liter TM$_{010}$ cavity within the magnet bore.
  • The amplifier operated via four-wave mixing in a lumped-element transmission line with embedded Josephson junctions, providing broadband gain across a 3 GHz bandwidth.
  • The pump frequency and power were tuned to optimize gain at specific frequencies, compensating for intrinsic gain oscillations spaced ~38 MHz apart.
  • Receiver chain performance was characterized using a noise source and calibration tones, with system noise temperature measured via the Y-Factor method.
  • Axion signal extraction used optimal filtering with a Maxwell-Boltzmann velocity distribution model, and power excesses above 3$\sigma$ were flagged as candidates.
  • Systematic uncertainties were evaluated by combining fractional uncertainties from magnetic field, cavity quality factor, attenuation, and SNRI fitting, with total uncertainty on axion power at 26%.

Experimental results

Research questions

  • RQ1Can a Josephson Traveling Wave Parametric Amplifier (JTWPA) be successfully deployed in a dark matter axion search experiment with sufficient sensitivity and stability?
  • RQ2What is the achievable sensitivity of the JTWPA-based receiver chain in detecting axion-like particles with axion-photon coupling strengths above $10^{-13}\ \text{GeV}^{-1}$?
  • RQ3How does the JTWPA’s broadband gain performance compare to conventional amplifiers like the JPA or MSA in the context of narrowband axion haloscope experiments?
  • RQ4To what extent do mechanical vibrations in the cavity insert affect the resonant frequency and thus the sensitivity of the search?
  • RQ5Can the JTWPA be operated reliably under accidental magnetic field exposure, and what recovery mechanisms are feasible?

Key findings

  • The JTWPA achieved sustained operation for several months during engineering runs and successfully operated through a magnetic field transient, recovering fully after warming above niobium's critical temperature.
  • A new exclusion bound was set for axion-like particles with coupling strength above $10^{-13}\ \text{GeV}^{-1}$ at an axion mass of 19.84 $\mu$eV, corresponding to a frequency range of 4796.7–4799.5 MHz.
  • The system noise temperature was measured to be low enough to enable detection of axion signals at the quantum limit, with a total uncertainty of 26% on the axion power measurement.
  • The resonant frequency of the cavity drifted from 4.7975 GHz to 4.7990 GHz during data-taking due to liquid helium reservoir filling, causing mechanical vibrations that shifted the cavity mode.
  • Two power excesses above 3$\sigma$ were identified, but they were not persistent across scans and were therefore not identified as axion candidates.
  • The dominant systematic uncertainties were attributed to cavity quality factor ($Q$) and SNRI fitting, each contributing 20% fractional uncertainty, with $B^2VC_{010}$ and $T_{\text{HFET}}/\epsilon$ also significant.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.