Skip to main content
QUICK REVIEW

[Paper Review] A Transfer Learning Approach for Automated Segmentation of Prostate Whole Gland and Transition Zone in Diffusion Weighted MRI

Saman Motamed, Isha Gujrathi|arXiv (Cornell University)|Sep 20, 2019
Prostate Cancer Diagnosis and TreatmentMedicine43 references11 citations
TL;DR

This paper proposes a transfer learning approach using a modified U-Net to improve automated segmentation of prostate whole gland and transition zone in diffusion-weighted MRI (DW-MRI), leveraging pre-trained features from a larger source cohort to enhance performance on smaller target cohorts. With as few as 30 fine-tuned target cases, the method achieves mean Dice scores of 0.80 for both structures—significantly outperforming non-transfer learning (0.65 and 0.51, respectively).

ABSTRACT

The segmentation of prostate whole gland and transition zone in Diffusion Weighted MRI (DWI) are the first step in designing computer-aided detection algorithms for prostate cancer. However, variations in MRI acquisition parameters and scanner manufacturing result in different appearances of prostate tissue in the images. Convolutional neural networks (CNNs) which have shown to be successful in various medical image analysis tasks including segmentation are typically sensitive to the variations in imaging parameters. This sensitivity leads to poor segmentation performance of CNNs trained on a source cohort and tested on a target cohort from a different scanner and hence, it limits the applicability of CNNs for cross-cohort training and testing. Contouring prostate whole gland and transition zone in DWI images are time-consuming and expensive. Thus, it is important to enable CNNs pretrained on images of source domain, to segment images of target domain with minimum requirement for manual segmentation of images from the target domain. In this work, we propose a transfer learning method based on a modified U-net architecture and loss function, for segmentation of prostate whole gland and transition zone in DWIs using a CNN pretrained on a source dataset and tested on the target dataset. We explore the effect of the size of subset of target dataset used for fine-tuning the pre-trained CNN on the overall segmentation accuracy. Our results show that with a fine-tuning data as few as 30 patients from the target domain, the proposed transfer learning-based algorithm can reach dice score coefficient of 0.80 for both prostate whole gland and transition zone segmentation. Using a fine-tuning data of 115 patients from the target domain, dice score coefficient of 0.85 and 0.84 are achieved for segmentation of whole gland and transition zone, respectively, in the target domain.

Motivation & Objective

  • Address the challenge of poor generalization in deep learning models for prostate segmentation when applied across different MRI acquisition protocols and scanners.
  • Overcome the limitations of training deep networks on small, domain-specific datasets by leveraging pre-trained features from a larger, source cohort.
  • Improve segmentation accuracy for both whole gland (WG) and transition zone (TZ) in diffusion-weighted MRI (DW-MRI), which are sensitive to acquisition parameter variations.
  • Provide clinicians with data-efficient guidelines on the minimum number of labeled cases needed for effective transfer learning in prostate segmentation.
  • Develop a modified Dice loss function to enhance performance in low-data regimes without requiring a separate detection network.

Proposed method

  • Fine-tune a pre-trained U-Net model on a small subset of labeled target-domain DW-MRI scans using transfer learning from a larger source cohort.
  • Apply a modified Dice loss function that reduces sensitivity to class imbalance and improves optimization in low-data settings.
  • Use a U-Net architecture with skip connections to preserve spatial resolution and capture multi-scale features for accurate segmentation.
  • Train the model end-to-end on the target domain using a subset of labeled images, starting from ImageNet-pretrained or source-cohort-trained encoder weights.
  • Evaluate performance using standard metrics including Dice Similarity Coefficient (DSC), with ablation studies on varying fine-tuning dataset sizes.
  • Compare transfer learning performance against a baseline model trained solely on the target domain without transfer.

Experimental results

Research questions

  • RQ1Can transfer learning from a large source cohort significantly improve segmentation accuracy on a smaller, target cohort with different MRI acquisition parameters?
  • RQ2What is the minimum number of labeled target-domain cases required to achieve clinically acceptable segmentation performance using transfer learning?
  • RQ3How does the proposed modified Dice loss function compare to the standard Dice loss in low-data regimes for prostate segmentation?
  • RQ4Does transfer learning eliminate the need for a separate prostate detection step in the segmentation pipeline?
  • RQ5How does model performance vary with increasing fine-tuning dataset size in the target domain?

Key findings

  • With only 30 fine-tuned cases from the target domain, the transfer learning model achieved a mean Dice Similarity Coefficient (DSC) of 0.80 for both whole gland and transition zone segmentation—compared to 0.65 and 0.51, respectively, without transfer learning.
  • Using 115 labeled target cases, the model reached a mean DSC of 0.85 for whole gland and 0.84 for transition zone, significantly outperforming the non-transfer learning baseline (0.71 DSC).
  • The modified Dice loss function improved segmentation performance in low-data regimes and eliminated the need for a separate prostate detection network.
  • Transfer learning enabled robust segmentation across different MRI scanners and acquisition protocols, reducing sensitivity to imaging parameter variations.
  • The results demonstrate that transfer learning allows high-accuracy segmentation with minimal labeling effort, providing a practical guideline for clinical data labeling.
  • The study confirms that leveraging pre-trained features from a larger source cohort is highly effective for cross-cohort prostate segmentation in DW-MRI.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.