[Paper Review] Application of bent crystals at IHEP 70-GeV accelerator to enhance the efficiency of its usage
This paper demonstrates the successful use of bent silicon crystals at the IHEP 70-GeV U-70 accelerator to enable high-efficiency, multiturn beam extraction, achieving up to 4×10¹¹ protons per spill with 65% extraction efficiency using a 3-mm, 0.9 mrad-bent crystal. The system enabled simultaneous operation of four experiments, including K± meson decay studies and secondary beam production, with no degradation in crystal performance over a 27-day irradiation period of 10²⁰ protons/cm².
Bent crystal was extracting 70-GeV protons with average intensity 4*10^11 (as measured in external beamline) per spill of 1.6 s duration, in parallel to the simultaneous work of two internal targets in the accelerator ring. An additional crystal, placed in the external beamline, was deflecting a small part of the extracted beam with intensity 10^7 protons toward another physics experiment. Crystal-extracted beam had a typical size of 4 mm by 4 mm fwhm at the end of the external beamline. Measurements for the extraction efficiency and other characteristics at the simultaneous work of four experimental set-ups are presented. With crystal working in the above-said regime during one month, no degradation of channeling was observed. The studies of extraction efficiency have been continued with new crystals.
Motivation & Objective
- To develop and demonstrate a high-efficiency, multiturn beam extraction method using bent silicon crystals at the IHEP 70-GeV accelerator.
- To enable simultaneous operation of multiple physics experiments by extracting beam via bent crystals while maintaining internal target operations.
- To assess the long-term stability and performance of bent crystals under high-intensity irradiation in a real accelerator environment.
- To explore the feasibility of using shorter, highly bent crystals to further improve extraction efficiency.
Proposed method
- Bent silicon crystals with 0.5–2 mrad bending angles were installed in straight sections 19 and 106 of the U-70 accelerator ring.
- Local orbit distortion systems in closed-loop operation were used to steer the beam precisely onto the crystals.
- Extraction occurred via septum magnets (OM-20 and OM-24) that captured the crystal-deflected beam, with partition thicknesses of 8 mm and 2.5 mm, respectively.
- A secondary crystal (Si30, ~9 mrad bent) deflected a small fraction (~10⁷ protons/cycle) into a separate beamline for additional experiments.
- Beam extraction efficiency was measured by comparing extracted intensity to the beam fraction directed onto the crystal, with ~4% measurement accuracy.
- Crystal performance was monitored over 27 days using repeated efficiency measurements and beam size characterization (4 mm × 4 mm FWHM at beamline end).
Experimental results
Research questions
- RQ1What is the maximum beam extraction efficiency achievable using bent silicon crystals in a 70-GeV proton accelerator?
- RQ2Can bent crystals enable simultaneous beam extraction for multiple experiments without degrading performance?
- RQ3How stable are bent crystal channeling properties under prolonged irradiation at high beam intensities?
- RQ4Can shorter, more highly bent crystals improve extraction efficiency beyond current values?
Key findings
- The 3-mm, 0.9 mrad-bent crystal achieved a beam extraction efficiency of 65% for 20% of the beam intensity directed onto the crystal.
- The 5-mm, 1.5 mrad-bent crystal achieved 42% extraction efficiency under the same beam fraction.
- Over a 27-day period, the Si19 crystal sustained an irradiation dose of ~10²⁰ protons/cm² with no measurable degradation in extraction efficiency (44±2% initially, 43±2% finally).
- The extracted beam had a typical size of 4 mm × 4 mm FWHM at the end of the external beamline, suitable for downstream experiments.
- Simulations suggest that shorter crystals (e.g., 1 mm or less) with optimized bending profiles could further increase extraction efficiency.
- The system successfully enabled simultaneous operation of four experiments: two internal targets (IT24, IT27) and two external beamlines (22, 23), including K± meson decay studies.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.