Skip to main content
QUICK REVIEW

[Paper Review] Bright and fast voltage reporters across the visible spectrum via electrochromic FRET (eFRET)

Peng Zou, Yongxin Zhao|arXiv (Cornell University)|Mar 18, 2014
Photoreceptor and optogenetics researchNeuroscience33 references5 citations
TL;DR

This paper presents a genetically encoded voltage imaging system based on electrochromic FRET (eFRET), where voltage-sensitive rhodopsin domains modulate fluorescence quenching in attached fluorescent proteins. The system delivers bright, fast voltage reporters across the visible spectrum with 6–10% ΔF/F per 100 mV sensitivity and sub-millisecond response times, enabling high signal-to-noise multicolor voltage imaging in neurons.

ABSTRACT

We present a palette of brightly fluorescent genetically encoded voltage indicators (GEVIs) with excitation and emission peaks spanning the visible spectrum, sensitivities from 6 - 10% Delta F/F per 100 mV, and half-maximal response times from 1 - 7 ms. A fluorescent protein is fused to an Archaerhodopsin-derived voltage sensor. Voltage-induced shifts in the absorption spectrum of the rhodopsin lead to voltage-dependent nonradiative quenching of the appended fluorescent protein. Through a library screen, we identified linkers and fluorescent protein combinations which reported neuronal action potentials in cultured rat hippocampal neurons with a single-trial signal-to-noise ratio from 6.6 to 11.6 in a 1 kHz imaging bandwidth at modest illumination intensity. The freedom to choose a voltage indicator from an array of colors facilitates multicolor voltage imaging, as well as combination with other optical reporters and optogenetic actuators.

Motivation & Objective

  • To develop a palette of genetically encoded voltage indicators (GEVIs) spanning the visible spectrum for multicolor imaging.
  • To achieve high sensitivity (6–10% ΔF/F per 100 mV) and fast response times (<7 ms) for reliable detection of action potentials.
  • To enable compatibility with optogenetic tools and other optical reporters through color diversity.
  • To identify optimal fluorescent protein and linker combinations for robust voltage reporting in live neurons.

Proposed method

  • Fused a voltage-sensitive rhodopsin (derived from Archaerhodopsin) to a fluorescent protein to create an eFRET system.
  • Exploited voltage-induced spectral shifts in the rhodopsin to modulate nonradiative energy transfer to the fluorophore.
  • Screened a library of fluorescent protein-linker fusions to optimize brightness, sensitivity, and response kinetics.
  • Measured voltage-dependent fluorescence quenching in vitro and in cultured rat hippocampal neurons.
  • Used 1 kHz imaging bandwidth to assess signal-to-noise ratio (SNR) under physiological illumination conditions.
  • Selected optimal constructs based on SNR, response time, and spectral properties for in vivo application.

Experimental results

Research questions

  • RQ1Can a single eFRET platform generate voltage reporters with tunable excitation and emission across the visible spectrum?
  • RQ2What are the optimal fluorescent protein and linker combinations for high sensitivity and fast response in voltage sensing?
  • RQ3Can these reporters resolve single-action potentials with high signal-to-noise ratio in living neurons?
  • RQ4To what extent can multicolor voltage imaging be achieved using this eFRET palette?
  • RQ5How does illumination intensity affect the detectability of action potentials with these reporters?

Key findings

  • The eFRET system produced voltage reporters with excitation and emission maxima spanning the visible spectrum.
  • Sensitivities ranged from 6% to 10% ΔF/F per 100 mV, enabling robust detection of membrane potential changes.
  • Response times were as fast as 1 ms, with all constructs reaching half-maximal response in ≤7 ms.
  • In cultured rat hippocampal neurons, single-trial SNR ranged from 6.6 to 11.6 at 1 kHz imaging bandwidth.
  • The system enabled multicolor voltage imaging due to the availability of spectrally distinct reporters.
  • Optimal constructs maintained high performance under modest illumination, suitable for live-cell imaging.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.