[Paper Review] CATIROC: an integrated chip for neutrino experiments using photomultiplier tubes

S. Conforti, M. Settimo|arXiv (Cornell University)|Nov 27, 2020
Neutrino Physics ResearchPhysics and Astronomy9 references11 citations
TL;DR

This paper presents CATIROC, a 16-channel ASIC designed for high-precision charge and time measurement in photomultiplier tubes (PMTs) used in large-scale neutrino experiments. It demonstrates that CATIROC is suitable for liquid scintillator detectors like JUNO, achieving sub-150 ps time resolution and 15 fC charge resolution, with optimized configurations mitigating dead time and charge pile-up effects in photon-counting mode.

ABSTRACT

An ASIC named CATIROC (Charge And Time Integrated Read Out Chip) has been developed for the next-generation neutrino experiments using a large number of photomultiplier tubes (PMTs). Each CATIROC provides the time and the charge measurements for 16 configurable input channels operating in trigger-less mode. Originally designed for the light emission in water Cherenkov detectors, we show in this paper that its use can be extended to liquid-scintillator based experiments. The $\\sim$26000 3-inch PMTs of the JUNO experiment, under construction in China, is a case in point. This paper describes the features of CATIROC with a special attention to the most critical points for its application to the time profile of the light emission in liquid scintillators. The achieved performances in both charge and time measurements can be inputs for future high-precision experiments making use of PMTs or other photo-sensitive detectors.

Motivation & Objective

  • To adapt CATIROC, originally designed for water Cherenkov detectors, to liquid scintillator-based neutrino experiments such as JUNO.
  • To evaluate CATIROC's performance in measuring charge and time for signals with extended temporal profiles typical of liquid scintillators (up to hundreds of nanoseconds).
  • To identify and mitigate critical issues such as trigger dead time and charge pile-up when multiple hits arrive within tens to hundreds of nanoseconds.
  • To validate CATIROC's suitability for photon-counting mode operation in large-scale PMT arrays, where single-photoelectron detection is common.
  • To provide a comprehensive characterization of CATIROC’s configurable parameters for optimal performance in liquid scintillator applications.

Proposed method

  • Characterization of CATIROC’s auto-trigger mode and compressed digital output for high-channel-count systems.
  • Measurement of time resolution using independent approaches, including correction for non-linearities in the TDC ramp.
  • Evaluation of charge linearity and resolution using high-gain (HG) and low-gain (LG) modes, with charge integration windows set to ~20 ns.
  • Systematic testing of trigger dead time (TTrigDeadTime) and digitization dead time (TDeadTime ~9 µs), including mitigation via the SCA system.
  • Use of a toy Monte Carlo simulation to assess the impact of signal wiggles on charge reconstruction accuracy.
  • Comparison of CATIROC’s response with an independent readout system using 3-inch PMTs, validated across a large sample of JUNO PMTs.

Experimental results

Research questions

  • RQ1Can CATIROC reliably measure charge and time for PMT signals with temporal spreads up to hundreds of nanoseconds, as found in liquid scintillators?
  • RQ2What is the effective dead time of CATIROC when processing multiple hits with inter-arrival times typical of liquid scintillator light emission?
  • RQ3To what extent does charge pile-up bias the measurement when two hits arrive within the trigger dead time window?
  • RQ4How does CATIROC’s performance in charge resolution and linearity compare under high-gain and low-gain configurations in the context of liquid scintillator signals?
  • RQ5Can CATIROC be effectively used in photon-counting mode for experiments like JUNO, where most PMTs detect only one photoelectron per event?

Key findings

  • CATIROC achieves a time resolution of better than 150 ps, with potential for further improvement through correction of TDC ramp non-linearities.
  • The charge resolution is 15 fC in high-gain mode and 73 fC in low-gain mode, with linearity deviation below 1% across the dynamic range.
  • The trigger threshold can be set as low as 0.16 pC (~0.3 PE), enabling detection of single photoelectrons with a PMT gain of 3×10⁶.
  • A dead time of approximately 9 µs is observed, primarily due to charge digitization, but can be mitigated via the SCA system to recover missed signals.
  • Charge pile-up and signal loss are minimized when CATIROC is properly configured, especially for inter-hit times within 250 ns, which covers 99% of cases in JUNO’s SPMT system.
  • The CATIROC response is consistent with independent readout systems, with a discrepancy in reconstructed mean and standard deviation of less than 0.01 ADC units and 0.3%, respectively, across typical PMT signal parameters.