Skip to main content
QUICK REVIEW

[Paper Review] Characterization of a double torsion pendulum used to detect spin-induced torque based on Beth's experiment

Runa Yasuda, A. Hatakeyama|arXiv (Cornell University)|May 13, 2021
Mechanical and Optical ResonatorsPhysics and Astronomy14 references2 citations
TL;DR

This study presents a double torsion pendulum system that achieves a photon-spin-induced torque sensitivity of 2×10⁻¹⁷ N·m over 10⁴ seconds, approaching the thermal noise limit. Using forced torsional oscillation with polarization-modulated circularly polarized light, the system confirms angular momentum transfer of ħ per photon, validating a modern replication of Beth’s 1936 experiment with enhanced sensitivity and passive vibration isolation.

ABSTRACT

We characterized a double torsion pendulum system, including measurements of the photon-spin-induced torque. Our experimental strategy was similar to that used in Beth's experiment, which was performed in 1936 to measure photon-spin-induced torque using forced oscillation caused by polarization modulation of light incident on a suspended object. Through simple passive isolation of the suspended object from external vibration noise, the achieved torque sensitivity was 2 x 10^{-17} N m in a measurement time of 10^4 s, which is close to the thermal noise limit and one order smaller than the minimum torque measured in Beth's experiment. The observed spin-induced torque exerted on the light-absorbing optics is consistent with the angular momentum transfer of hbar per photon.

Motivation & Objective

  • To develop a high-sensitivity torsion pendulum system for detecting photon-spin-induced torque.
  • To replicate Beth’s 1936 experiment using a modern forced oscillation method with improved noise isolation.
  • To measure the angular momentum transfer of ħ per photon from circularly polarized light to a light-absorbing object.
  • To confirm that observed torque arises from photon spin, not radiation pressure or other spurious effects.
  • To demonstrate the feasibility of using the double pendulum for future studies of spin transfer from atomic gases to solids.

Proposed method

  • Employed a double torsion pendulum with the first stage acting as a passive vibration isolator to reduce environmental noise.
  • Used a red probe laser and position-sensitive detector (PSD) for optical lever angle measurement with dφ = dx/(2L).
  • Applied a 852 nm laser with polarization modulated via a liquid crystal variable retarder (LCVR) to periodically flip photon spin from +ħ to -ħ.
  • Performed forced torsional oscillation at the pendulum’s resonance frequency (0.11 Hz) and used lock-in detection with quadrature components for signal extraction.
  • Calculated torque sensitivity using the measured quadrature component uncertainty and system parameters (Q, ωR, I) via Eq. (3).
  • Estimated thermal noise limit using Nther = π/4 × √(4kBTIωR/(Q∆t)) and compared it to experimental sensitivity.

Experimental results

Research questions

  • RQ1Can a double torsion pendulum system achieve torque sensitivity close to the thermal noise limit in detecting photon-spin-induced torque?
  • RQ2Does the observed torque on a light-absorbing ND filter match the expected angular momentum transfer of ħ per photon from circularly polarized light?
  • RQ3Is the measured torque primarily due to photon spin, or are contributions from radiation pressure or radiometer effects significant?
  • RQ4How does passive isolation via a double pendulum architecture improve sensitivity compared to Beth’s original setup?
  • RQ5Can this system reliably detect spin-induced torque at the 10⁻¹⁷ N·m level with a 10⁴ s integration time?

Key findings

  • The torque sensitivity of the system was measured at 2×10⁻¹⁷ N·m over a 10⁴ s measurement time, which is close to the thermal noise limit of 2×10⁻¹⁷ N·m.
  • The observed photon-spin-induced torque on the ND filter is consistent with angular momentum transfer of ħ per photon for left-circularly polarized light.
  • The polarization dependence of the torque showed a linear relationship with the photon spin component along the propagation direction, confirming spin origin.
  • Radiation pressure torque contribution was estimated at 1×10⁻¹⁸ N·m, which is negligible compared to the observed 1×10⁻¹⁶ N·m modulation from polarization changes.
  • The quadrature component uncertainty of 0.1 µrad in 10⁴ s measurements translates to a torque detection uncertainty of 2×10⁻¹⁷ N·m, matching the thermal noise limit.
  • The system successfully demonstrated a modern, high-sensitivity replication of Beth’s 1936 experiment using passive isolation and lock-in detection.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.