[Paper Review] Characterization of an MPPC-Based Scintillator Telescope and Measurement of Cosmic Muon Angular Distribution

Sahla Manithottathil, Anuj Gupta|arXiv (Cornell University)|Feb 18, 2026
Radiation Detection and Scintillator TechnologiesPhysics and Astronomy0 citations
TL;DR

The paper designs and characterizes an MPPC-coupled plastic scintillator telescope, calibrates gain and dark count rates, employs a three-fold coincidence target, and measures the cosmic muon angular distribution, yielding n = 1.44 ± 0.06 for I(θ) ∝ cos^n(θ).

ABSTRACT

This report presents the design, characterization, and application of a high-sensitivity optical detection system based on plastic scintillators coupled to Multi-Pixel Photon Counters (MPPCs). The primary objective was to evaluate the performance of MPPCs (Silicon Photomultipliers) as robust, low-voltage alternatives to traditional photomultiplier tubes for detecting faint scintillation light. The optoelectronic properties of the sensors were analyzed, including single-photoelectron gain calibration and dark count rate measurements, to optimize the signal-to-noise ratio. By embedding wavelength-shifting fibers to enhance light collection efficiency, the system was configured into a three-fold coincidence telescope. The angular distribution of the cosmic ray muon flux was measured to validate the detector's stability and geometric acceptance. Fitting the experimental data to a $\bm{\cos^n(θ)}$ distribution yielded an angular exponent of $\bm{n = 1.44 \pm 0.06}$, consistent with literature values. These results demonstrate the efficacy of the MPPC-scintillator coupling for precise photon counting and timing applications in high-energy physics instrumentation.

Motivation & Objective

  • Motivate robust, low-voltage photon counting detectors (MPPCs) for scintillator-based muon detection.
  • Characterize MPPC gain and dark count rate to optimize signal-to-noise and triggering thresholds.
  • Develop a three-fold coincidence telescope to measure muon angular distribution with controlled geometric acceptance.
  • Measure muon flux as a function of zenith angle and compare to theoretical models.
  • Validate MPPC-scintillator coupling for precision timing and counting in high-energy instrumentation.

Proposed method

  • Use plastic scintillators with wavelength-shifting fibers to couple light to MPPCs.
  • Calibrate single photoelectron gain from dark-count pulses to set amplitude thresholds.
  • Characterize dark count rate as function of threshold and temperature dependence.
  • Implement three-fold coincidence telescope (top, middle, bottom detectors) with a coincidence window ~200 ns.
  • Determine optimal operating threshold (3 p.e.) to minimize accidental coincidences (R_acc ≈ 6.6×10^-5 Hz).
  • Fit measured angular distribution to cos^n(θ) models and to curvature-aware/empirical Schwerdt models for comparison.

Experimental results

Research questions

  • RQ1What is the angular dependence of the ground-level cosmic muon flux as measured by a three-fold MPPC-based scintillator telescope?
  • RQ2What MPPC operating settings (gain, threshold) maximize muon detection efficiency while suppressing instrumental background?
  • RQ3How well do different muon angular distribution models describe the data obtained with the telescope (cos^2, cos^n, Shukla & Sankrith, Schwerdt)?
  • RQ4Is the three-fold coincidence approach effective at rejecting accidental coincidences and isolating penetrating muons?
  • RQ5What is the measured value of the angular exponent for the muon flux, and how does it compare with literature?

Key findings

  • The three-fold coincidence configuration with a 3 p.e. threshold yields negligible accidental coincidences (≈6.6×10^-5 Hz).
  • Measured single-p.e. charges indicate MPPC gains around 1.7×10^6 to 3.0×10^6 across channels.
  • Surface vs penetrating triggers show higher rate for surface (0.343 Hz) than penetrating (0.189 Hz), validating muon penetration selection.
  • Angular distribution fit yields an exponent n = 1.44 ± 0.06 for I(θ) ∝ cos^n(θ).
  • MPPC-based scintillator readout demonstrates high gain (10^5–10^6) and effective dark-count management for precise photon counting and timing.