Skip to main content
QUICK REVIEW

[Paper Review] Design and construction of a cryogenic subcooler-box for supplying single phase supercritical helium to dark matter and gravitational wave experiments

Udai Raj Singh, Rajinikumar Ramalingam|arXiv (Cornell University)|Jan 13, 2026
Superconducting Materials and ApplicationsEngineering0 citations
TL;DR

The paper describes the design, development, and installation of the ALPS Cryo-Platform Subcooler Box (ACPS) at DESY to subcool and distribute supercritical helium for multiple cryogenic experiments with high heat loads, including mass-flow calculations and operational modes.

ABSTRACT

We report on the design, development, and installation of the ALPS Cryo-Platform Subcooler Box (ACPS), which is part of the cryogenic platform being established in the HERA North Hall at DESY to supply helium for cooling large-scale dark-matter and gravitational-wave experiments with very high heat loads. The ACPS is capable of subcooling supercritical helium supplied via the 1.6-km-long HERA transfer line by means of a pipe heat exchanger immersed in a subcooler bath filled with liquid helium produced through Joule-Thomson valves. It is also equipped with numerous cryogenic components, including control valves, flow meters, and safety valves, enabling experimental operation to be carried out directly by the ACPS itself and thereby reducing the cryogenic requirements imposed on the experiments. To support a wide range of experiments, the ACPS provides three transfer lines that deliver different levels of cooling power.

Motivation & Objective

  • Address the need for high-heat-load cryogenics for large-scale dark matter and gravitational-wave experiments at DESY.
  • Design and implement a subcooling solution to bring supercritical helium from the HERA transfer line to ~4.5 K for multiple experiments.
  • Provide independent helium transfer lines and integrated cryogenic components to reduce external cryogenic requirements for experiments.
  • Characterize mass-flow requirements and operational modes to support cooldown, warm-up, liquefaction, and safety.

Proposed method

  • Design of the ACPS with a subcooler bath, integrated pipe heat exchanger (PHEX), and Joule–Thomson (JT) valves.
  • Circuit analysis of the 4.5–5 K and 40–80 K circuits to support three experiments and potentially a fourth.
  • Mass-flow calculations using heat-load scenarios and helium enthalpies from a CB42 refrigerator and 4.5 K return to size valves, pipes, and sensors.
  • Evaluation of operational modes including pumping, purging, liquefaction, independent cooldown/warm-up, and safety discharge.
  • 3D design, fabrication, installation, and acceptance testing procedures for ACPS.

Experimental results

Research questions

  • RQ1How can a cryogenic subcooler box be designed to subcool and distribute helium to multiple experiments with high heat loads?
  • RQ2What are the mass-flow requirements and enthalpy considerations to size valves, heat exchangers, and sensors for independent experiment operation?
  • RQ3What operational modes and safety measures are needed for reliable, standalone ACPS performance?

Key findings

  • ACPS can subcool supercritical helium from the HERA transfer line to ~4.5 K at 1.3–3.5 bar for experiments.
  • Region-specific mass-flow requirements range from 6–30 g/s for TL1 to Exp. 1 and 2–10 g/s for TL2/TL3 to Exp. 2 and Exp. 3, with additional allocations for Exp. 4.
  • 40–80 K circuit loads indicate total heat loads of 5476.9 W (Scenario 1) and 7177.6 W (Scenario 2) across TLs and boxes.
  • Final mass-flow rates and temperatures for 4.5 KF/5 KR and 40 KF/80 KR lines are provided with contingency (approximately 20%).
  • Liquefaction rates for Exp. 1–3 are 3.0 g/s (Exp. 1) and 3.0 g/s (Exp. 2) for the 1.8 K baths, with variable liquefaction via JT valves.
  • The ACPS supports independent cooldown/warm-up and safe discharge pathways through safety valves.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.