TL;DR

This paper proposes a fast wavelet collocation (FWC) method to directly determine the absolute magnetic penetration depth λ in small-sized, polygonal superconducting films, overcoming limitations of conventional flux leakage subtraction (FLS) methods. The FWC method enables accurate λ extraction independent of film size, validated by consistent λ values across different-sized NbN films, including a 5×5 mm² film where FLS failed due to edge current effects.

ABSTRACT

In the previous four decades, a two-coil mutual inductance (MI) technique has been widely employed in characterizing magnetic penetration depth, $\lambda$, of superconducting films. However, the conventional methods used to obtain $\lambda$ are not applicable to small-sized films with common shapes, which limits the application of the MI technique in superconductivity research. Here, we first employed the fast wavelet collocation (FWC) method to a two-coil system and then proposed the possibility of directly obtaining the absolute $\lambda$ of polygonal superconducting films with arbitrary sizes. To verify its accuracy and advantages, we extracted the $\lambda$ values of square NbN films with different sizes using the FWC and conventional flux leakage subtraction (FLS) methods. Notably, the FLS method fails for a $5 imes 5 \, m mm^2$ film, which is attributed to the significant current peak at the film edge. In contrast, the absolute $\lambda$ extracted using the FWC method was independent of the film size. Finally, we established the applicability of the FWC method to large coil spacings, which may pave the way for integrating high-accuracy $\lambda$ measurements with the ionic liquid gating technique.

Motivation & Objective

  • Overcome the inability of conventional flux leakage subtraction (FLS) methods to accurately determine the absolute magnetic penetration depth λ in small-sized superconducting films.
  • Address the failure of FLS for films with significant edge current effects, such as 5×5 mm² square NbN films.
  • Develop a numerical method applicable to polygonal superconducting films of arbitrary size and shape.
  • Enable high-accuracy λ measurements compatible with advanced techniques like ionic liquid gating by extending applicability to large coil spacings.

Proposed method

  • Employ the fast wavelet collocation (FWC) method to solve the integral equation governing the mutual inductance in a two-coil system with a superconducting film.
  • Model the screening current distribution on the film using wavelet-based collocation to handle complex geometries and edge effects.
  • Use the FWC method to extract λ directly from measured mutual inductance data without relying on flux leakage subtraction.
  • Validate the method by comparing FWC-extracted λ values with those from the conventional FLS method on square NbN films of varying sizes.
  • Establish the method’s robustness by demonstrating consistent λ values across different film sizes, including large films where FLS fails.
  • Extend the FWC framework to large coil spacings, enabling integration with ionic liquid gating and other in-situ measurement techniques.

Experimental results

Research questions

  • RQ1Can the FWC method provide accurate and size-independent determination of the absolute magnetic penetration depth λ in small-sized, non-circular superconducting films?
  • RQ2Why does the conventional FLS method fail for large, small-sized superconducting films like 5×5 mm² square NbN films?
  • RQ3To what extent does the FWC method remain accurate when coil spacing increases, enabling compatibility with in-situ techniques?
  • RQ4How does the FWC method handle strong edge current effects that distort flux leakage in conventional FLS approaches?
  • RQ5Can the FWC method be generalized to arbitrary polygonal film shapes and sizes without prior assumptions about geometry or symmetry?

Key findings

  • The FWC method successfully extracted the absolute magnetic penetration depth λ for square NbN films of various sizes, yielding consistent values independent of film size.
  • For a 5×5 mm² NbN film, the conventional FLS method failed due to a significant current peak at the film edge, which distorted the flux leakage correction.
  • The FWC method achieved accurate λ extraction even in the presence of strong edge effects, demonstrating robustness beyond the applicability limit of FLS.
  • The FWC method was validated to be independent of film size, with extracted λ values remaining constant across different film dimensions.
  • The FWC method was shown to be applicable to large coil spacings, enabling future integration with ionic liquid gating and other in-situ measurement techniques.
  • The FWC method provides a reliable, size-independent alternative to FLS for measuring λ in small, non-circular superconducting films.