TL;DR

The paper develops and validates deep learning models to automatically detect critical findings on non-contrast head CTs—ICH (and subtypes), fractures, midline shift, and mass effect—using large multicenter datasets (Qure25k and CQ500) and reports AUCs and operating point performances.

ABSTRACT

Importance: Non-contrast head CT scan is the current standard for initial imaging of patients with head trauma or stroke symptoms. Objective: To develop and validate a set of deep learning algorithms for automated detection of following key findings from non-contrast head CT scans: intracranial hemorrhage (ICH) and its types, intraparenchymal (IPH), intraventricular (IVH), subdural (SDH), extradural (EDH) and subarachnoid (SAH) hemorrhages, calvarial fractures, midline shift and mass effect. Design and Settings: We retrospectively collected a dataset containing 313,318 head CT scans along with their clinical reports from various centers. A part of this dataset (Qure25k dataset) was used to validate and the rest to develop algorithms. Additionally, a dataset (CQ500 dataset) was collected from different centers in two batches B1 & B2 to clinically validate the algorithms. Main Outcomes and Measures: Original clinical radiology report and consensus of three independent radiologists were considered as gold standard for Qure25k and CQ500 datasets respectively. Area under receiver operating characteristics curve (AUC) for each finding was primarily used to evaluate the algorithms. Results: Qure25k dataset contained 21,095 scans (mean age 43.31; 42.87% female) while batches B1 and B2 of CQ500 dataset consisted of 214 (mean age 43.40; 43.92% female) and 277 (mean age 51.70; 30.31% female) scans respectively. On Qure25k dataset, the algorithms achieved AUCs of 0.9194, 0.8977, 0.9559, 0.9161, 0.9288 and 0.9044 for detecting ICH, IPH, IVH, SDH, EDH and SAH respectively. AUCs for the same on CQ500 dataset were 0.9419, 0.9544, 0.9310, 0.9521, 0.9731 and 0.9574 respectively. For detecting calvarial fractures, midline shift and mass effect, AUCs on Qure25k dataset were 0.9244, 0.9276 and 0.8583 respectively, while AUCs on CQ500 dataset were 0.9624, 0.9697 and 0.9216 respectively.

Motivation & Objective

  • Motivate automated triage and rapid identification of urgent head CT findings to reduce treatment delays.
  • Develop large-scale, center-diverse datasets (Qure25k and CQ500) with radiology reports and expert consensus as gold standards.
  • Train separate deep learning models for intracranial hemorrhages, fractures, and mass effect/midline shift.
  • Provide per-findings performance metrics to support clinical deployment and benchmarking.

Proposed method

  • Train slice-level hemorrhage classifiers using ResNet18 with five parallel fully connected layers for each hemorrhage type and combine slice confidences with a random forest for scan-level prediction.
  • Train dense segmentation models (UNet) for IPH, SDH, EDH, and use a DeepLab-based approach for calvarial fracture detection with hard negative mining to address sparsity.
  • Use a two-branch approach for midline shift and mass effect with a modified ResNet18 and parallel FC layers, aggregated via random forest to obtain scan-level confidences.
  • Preprocess CT scans by selecting axial non-contrast series, resampling to 5 mm, resizing to 224x224, and stacking brain, bone, and subdural windows as channels.
  • Evaluate using ROC curves with AUC as primary metric, and report sensitivities and specificities at high-sensitivity and high-specificity operating points.

Experimental results

Research questions

  • RQ1Can deep learning models accurately detect five types of intracranial hemorrhage on non-contrast head CTs across diverse centers?
  • RQ2Can models reliably detect calvarial fractures, midline shift, and mass effect, and how do they compare to radiologist consensus?
  • RQ3How do model performances generalize between development (Qure25k) and independent clinical validation (CQ500) datasets?
  • RQ4What is the impact of using a majority radiologist consensus versus single-reader gold standards on measured performance?
  • RQ5Can an automated triage system reduce time to treatment by providing reliable scan triage in busy or remote settings?

Key findings

  • On Qure25k, AUCs were 0.9194 for ICH, 0.9544 for intraventricular hemorrhage, 0.9276 for midline shift, 0.9244 for calvarial fracture, and 0.8583 for mass effect.
  • On CQ500 (B1+B2), AUCs were 0.9419 for ICH, 0.9544 for IPH, 0.9310 for IVH, 0.9521 for SDH, 0.9731 for EDH, 0.9574 for SAH, 0.9624 for calvarial fracture, 0.9697 for midline shift, and 0.9216 for mass effect.
  • At high sensitivity operating points on CQ500, sensitivities were 0.9463 (ICH), 0.9487 (calvarial fracture), 0.9385 (midline shift) with specificities 0.7098, 0.8606, 0.8944 respectively.
  • The algorithms achieved higher AUCs on CQ500 than on Qure25k, with mass effect showing the largest disparity (0.9216 vs 0.8583).
  • CQ500 showed higher reader concordance for ICH (Fleiss’ kappa 0.7827) and IPH (0.7746) than for calvarial fracture (0.4507) and SDH (0.5418).
  • The study provides publicly accessible CQ500 dataset for benchmarking and demonstrates per-finding deep learning performance on head CTs.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.