[Paper Review] A Simple, Fast and Fully Automated Approach for Midline Shift Measurement on Brain Computed Tomography

Huan-Chih Wang, Shih-Hao Ho|arXiv (Cornell University)|Mar 2, 2017
Traumatic Brain Injury and Neurovascular DisturbancesMedicine12 references6 citations
TL;DR

This paper presents a fast, fully automated method for measuring midline shift (MLS) on brain CT scans using a weighted midline (WML) derived from pixel intensity, with the ideal midline (IML) near the foramen of Monro as reference. The system achieves 90.24% accuracy on average, rising to 92.68% with manual head rotation calibration, and introduces a novel normalized parameter, MLS/ICWMAX, which performs comparably to MLS in clinical assessment, especially for non-DICOM images.

ABSTRACT

Brain CT has become a standard imaging tool for emergent evaluation of brain condition, and measurement of midline shift (MLS) is one of the most important features to address for brain CT assessment. We present a simple method to estimate MLS and propose a new alternative parameter to MLS: the ratio of MLS over the maximal width of intracranial region (MLS/ICWMAX). Three neurosurgeons and our automated system were asked to measure MLS and MLS/ICWMAX in the same sets of axial CT images obtained from 41 patients admitted to ICU under neurosurgical service. A weighted midline (WML) was plotted based on individual pixel intensities, with higher weighted given to the darker portions. The MLS could then be measured as the distance between the WML and ideal midline (IML) near the foramen of Monro. The average processing time to output an automatic MLS measurement was around 10 seconds. Our automated system achieved an overall accuracy of 90.24% when the CT images were calibrated automatically, and performed better when the calibrations of head rotation were done manually (accuracy: 92.68%). MLS/ICWMAX and MLS both gave results in same confusion matrices and produced similar ROC curve results. We demonstrated a simple, fast and accurate automated system of MLS measurement and introduced a new parameter (MLS/ICWMAX) as a good alternative to MLS in terms of estimating the degree of brain deformation, especially when non-DICOM images (e.g. JPEG) are more easily accessed.

Motivation & Objective

  • To develop a fully automated, fast, and accurate method for midline shift (MLS) measurement on brain CT scans.
  • To address the clinical challenge of reliable and reproducible MLS quantification in emergency neuroimaging.
  • To introduce and validate a new normalized parameter, MLS/ICWMAX, as a robust alternative to MLS, particularly for non-DICOM images.
  • To reduce inter-rater variability and time burden in MLS assessment by replacing manual measurements with automated computation.

Proposed method

  • A weighted midline (WML) is computed based on pixel intensity, assigning higher weights to darker regions to reflect anatomical symmetry.
  • The ideal midline (IML) is defined near the foramen of Monro as a reference for measuring distance to the WML.
  • Midline shift (MLS) is calculated as the Euclidean distance between the WML and IML on axial CT slices.
  • The ratio MLS/ICWMAX is introduced, where ICWMAX is the maximum width of the intracranial region, normalizing MLS for patient size and scanner variability.
  • Automatic image calibration is applied to correct for head rotation, with manual calibration used as a performance benchmark.
  • The system processes each CT study in approximately 10 seconds on average.

Experimental results

Research questions

  • RQ1Can a fully automated system achieve high accuracy in midline shift measurement on brain CT scans?
  • RQ2How does the performance of the proposed MLS/ICWMAX ratio compare to traditional MLS in clinical assessment?
  • RQ3To what extent does automatic calibration affect the accuracy of automated MLS measurement?
  • RQ4Can the proposed method reliably process non-DICOM images such as JPEGs, which are common in clinical workflows?

Key findings

  • The automated system achieved an overall accuracy of 90.24% when using automatic image calibration for head rotation correction.
  • With manual head rotation calibration, the system's accuracy improved to 92.68%.
  • The MLS/ICWMAX parameter produced confusion matrices and ROC curve results that were nearly identical to those of MLS, indicating equivalent diagnostic performance.
  • The average processing time per study was approximately 10 seconds, demonstrating high speed and practicality for clinical use.
  • The method demonstrated robustness and accuracy even when applied to non-DICOM images, such as JPEGs, making it suitable for real-world clinical deployment.