Skip to main content
QUICK REVIEW

[Paper Review] Effect of PEG binder on gas sensitivity of ferric oxide films synthesized by spin coating and doctor blade methods

P. Samarasekara, M.S.P.K. Gunasinghe|arXiv (Cornell University)|Nov 22, 2018
Gas Sensing Nanomaterials and SensorsEngineering23 references3 citations
TL;DR

This study investigates the impact of polyethylene glycol (PEG) binder on the gas-sensing performance of spin-coated and doctor-bladed ferric oxide (Fe2O3) thin films. PEG incorporation enhances gas sensitivity by 15.44%, reduces response and recovery times, and lowers the optical band gap, primarily due to reduced activation energy, without altering the primary phase or functional groups as confirmed by XRD and FTIR analyses.

ABSTRACT

Ferric oxide (Fe2O3) thin films were fabricated on amorphous nonconductive and FTO conductive glass substrates starting from iron acetate nanoparticles by the doctor blade and the spin coating techniques. Thin films of Fe2O3 with and without the PEG binder were investigated. Films were subsequently annealed at 500 0C in air for 1 hour to crystallize the phase Fe2O3. The structural and chemical properties of Fe2O3 thin films were determined using XRD and FTIR. According to XRD, the single phase of Fe2O3 crystallized in the thin film after annealing. The optical band gap of synthesized Fe2O3 thin films were determined by UV-Visible spectrums. Gas sensitivity, respond time and recovery time of Fe2O3 thin films were measured in 1000ppm of CO2 gas using AUTO LAB. Thin films synthesized by the doctor blade method were thicker and more uniform than the thin films prepared by the spin coating technique. Gas sensitivity of Fe2O3 films synthesized by the doctor blade method is slightly higher than that of the films fabricated by the spin coating technique. Fe2O3 films with the PEG binder posses a higher gas sensitivity, lower respond time and lower recovery time compared to films without PEG binder. After adding the PEG binder, the optical band gap of Fe2O3 thin films reduces. The reduction of the activation energy is the reason for the improvement of the gas sensitivity after adding the PEG. However, the peak positions of FTIR do not indicate any significant change due to the adding of the PEG. Adding the binder increased the gas sensitivity of iron oxide by 15.44%. Both FTIR and UV-Visible data confirm the formation of Fe2O3 in the thin film.

Motivation & Objective

  • To evaluate the influence of PEG binder on the gas-sensing performance of Fe2O3 thin films fabricated by spin coating and doctor blading.
  • To compare the structural, optical, and gas-sensing properties of Fe2O3 films with and without PEG binder.
  • To determine how film deposition technique (spin coating vs. doctor blading) affects film morphology and gas sensitivity.
  • To correlate changes in optical band gap and activation energy with enhanced gas response after PEG addition.
  • To validate the formation of pure hematite (α-Fe2O3) phase and assess chemical stability using XRD and FTIR spectroscopy.

Proposed method

  • Synthesized iron acetate nanoparticles as precursor for Fe2O3 thin films.
  • Deposited films on FTO and non-conductive glass substrates using spin coating and doctor blading techniques.
  • Annealed films at 500 °C for 1 hour in air to achieve crystalline α-Fe2O3 phase.
  • Characterized structural properties using X-ray diffraction (XRD) and chemical composition via Fourier-transform infrared spectroscopy (FTIR).
  • Measured optical band gap using UV-Visible spectroscopy.
  • Evaluated gas sensitivity, response time, and recovery time toward 1000 ppm CO2 using an AUTO LAB system.

Experimental results

Research questions

  • RQ1How does the addition of PEG binder affect the gas sensitivity of Fe2O3 thin films fabricated by spin coating and doctor blading?
  • RQ2What is the influence of deposition method (spin coating vs. doctor blading) on film thickness, uniformity, and gas-sensing response?
  • RQ3How does PEG incorporation alter the optical band gap and activation energy of Fe2O3 thin films?
  • RQ4Does PEG introduce new functional groups or phase impurities in Fe2O3 films, as detected by FTIR and XRD?
  • RQ5What is the quantitative improvement in gas response, response time, and recovery time due to PEG addition?

Key findings

  • Fe2O3 films synthesized by the doctor blading method were thicker and more uniform than those made by spin coating.
  • The gas sensitivity of Fe2O3 films increased by 15.44% after incorporation of PEG binder.
  • PEG-containing films exhibited shorter response and recovery times compared to PEG-free films.
  • The optical band gap of Fe2O3 thin films decreased following PEG addition, indicating enhanced electronic conductivity.
  • XRD confirmed the formation of single-phase α-Fe2O3 after annealing, with no significant change in peak positions due to PEG.
  • FTIR spectra showed no significant chemical changes due to PEG, indicating it does not alter the primary chemical bonding in Fe2O3.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.