Skip to main content
QUICK REVIEW

[Paper Review] Enhancement of the X-Arapuca photon detection device for the DUNE experiment

C. Brizzolari, Sergio Brovelli|arXiv (Cornell University)|Jan 1, 2021
Neutrino Physics ResearchPhysics and Astronomy26 references30 citations
TL;DR

This paper presents a 50% enhancement in photon detection efficiency (PDE) of the X-Arapuca light trap for the DUNE experiment by developing a novel wavelength-shifting polymer (G2P FB118) and integrating a cryogenic trans-impedance amplifier for improved single-photoelectron sensitivity. The new WLS material, combined with a specular reflector on the slab edges, significantly boosts light collection in liquid argon, enabling higher PDE (2.9 ± 0.1%) compared to the baseline (1.8 ± 0.1%) without cross-talk corrections.

ABSTRACT

In the Deep Underground Neutrino Experiment (DUNE), the VUV LAr luminescence is collected by light trap devices named X-Arapuca, sizing (480x93) mm2. Six thousand of these units will be deployed in the first DUNE ten kiloton far detector module. In this work we present the first characterization of the photon detection efficiency of an X-Arapuca device sizing (200x75) mm2 via a complete and accurate set of measurements along the cell longitudinal axis with a movable 241-Am source. The MPPCs photosensors are readout by a cryogenic transimpedance amplifier to enhance the single photoelectron sensitivity and improve the signal-to-noise while ganging 8 MPPC for a total surface of 288 mm2. Moreover we developed a new photon downshifting polymeric material, by which the X-Arapuca photon detection efficiency was enhanced of about +50% with respect to the baseline off-shell product deployed in the standard device configuration. The achieved results are compared to previous measurements on a half size X-Arapuca device, with a fixed source facing the center, with no cold amplification stage, and discussed in view of the DUNE full size optical cell construction for both the horizontal and the vertical drift configurations of the DUNE TPC design and in view of liquid Argon doping by ppms of Xe. Other particle physics projects adopting Liquid Argon as target or active veto, as Dark Side and LEGEND or the DUNE Near Detector will take advantage of this novel wavelength shifting material.

Motivation & Objective

  • To improve the photon detection efficiency (PDE) of the X-Arapuca device for the DUNE far detector, which is critical for detecting supernova neutrino bursts.
  • To address the challenge of low PDE in large-area liquid argon time projection chambers (LAr TPCs), where VUV light from Ar2* de-excitation must be efficiently downshifted and collected.
  • To develop and validate a new, high-performance wavelength-shifting (WLS) polymer for use in LAr-based experiments, with enhanced light transmission and reflectivity.
  • To optimize the X-Arapuca design through cryogenic readout of SiPMs using a cold trans-impedance amplifier, improving signal-to-noise ratio and single-photoelectron sensitivity.
  • To establish a reproducible, high-purity liquid argon liquefaction method to minimize PDE corrections due to impurities and enable accurate, comparable measurements across configurations.

Proposed method

  • Conducted room-temperature, vacuum, and cryogenic measurements using a movable 241Am alpha source to scan the longitudinal axis of a 200×75 mm² X-Arapuca prototype.
  • Implemented a cryogenic trans-impedance amplifier (TIA) with BFP640 SiGe HBT and THS4531 op-amp to read out eight MPPCs (total 288 mm²) at liquid argon temperature, enhancing single-photoelectron sensitivity and signal-to-noise ratio.
  • Developed and tested a new polymeric WLS material (G2P FB118) with improved light transmission and reflectivity compared to the baseline Eljen EJ-286, using a 3M Vikuiti® specular reflector on the slab edges.
  • Performed absolute PDE measurements in liquid argon by calibrating the single-photoelectron response using the 241Am alpha spectrum and correcting for cross-talk (−18 ± 1%) and LAr purity (up to +2.6%).
  • Used the formula P_LAr = (0.77 + 0.23 × τ_T / 1414 ns)⁻¹ to correct for triplet decay time effects, ensuring accurate PDE normalization.
  • Compared PDE across three configurations: baseline EJ-286 without reflector, EJ-286 with reflector, and G2P FB118 with reflector, using peak mean ratios (μ_FB118 / μ_EJ-286) to compute relative PDE gain (Gε).

Experimental results

Research questions

  • RQ1What is the absolute photon detection efficiency (PDE) of the X-Arapuca device when using the novel G2P FB118 WLS polymer compared to the baseline Eljen EJ-286?
  • RQ2How does the integration of a cryogenic trans-impedance amplifier affect the signal-to-noise ratio and single-photoelectron sensitivity in liquid argon?
  • RQ3To what extent does applying a specular reflector (Vikuiti®) on the edges of the WLS slab enhance the PDE in both air and liquid argon?
  • RQ4How do LAr purity and triplet decay time (τ_T) corrections impact the accuracy of PDE measurements in liquid argon?
  • RQ5Can a clean, reproducible method for liquefying high-purity argon be established to minimize PDE corrections and enable direct comparison across measurement campaigns?

Key findings

  • The X-Arapuca device achieved a 50% increase in PDE when replacing the baseline Eljen EJ-286 WLS material with the novel G2P FB118 polymer, resulting in a PDE of 2.9 ± 0.1% compared to 1.8 ± 0.1% for the baseline.
  • The addition of a 3M Vikuiti® specular reflector on the WLS slab edges increased the PDE by approximately 10 ± 1% in liquid argon, with a larger 40% increase observed at room temperature.
  • The cryogenic trans-impedance amplifier improved the signal-to-noise ratio to 7.3 ± 0.3, enhancing single-photoelectron sensitivity and enabling accurate absolute PDE measurements in liquid argon.
  • The measured PDE of 1.8 ± 0.1% for the baseline configuration is lower than previous reports (3.5 ± 0.5%) due to differences in overvoltage (+2.7 V vs. +5 V), lack of cold front-end electronics, and fixed-source geometry in earlier measurements.
  • The singlet and triplet decay time constants (τ_S = 6 ns, τ_T = 1294 ± 35 ns) and their relative amplitudes (0.77 and 0.23) were measured in agreement with previous literature, validating the measurement framework.
  • A high-purity, reproducible liquid argon liquefaction procedure was established, minimizing PDE corrections due to impurities (≤2.6%) and enabling direct comparison across different measurement campaigns.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.