Skip to main content
QUICK REVIEW

[Paper Review] Ferromagnetic dynamics detected via one- and two-magnon NV relaxometry

Brendan McCullian, Ahmed M. Thabt|arXiv (Cornell University)|Nov 3, 2019
Diamond and Carbon-based Materials ResearchMaterials Science48 references6 citations
TL;DR

This paper introduces a two-magnon Raman-like relaxation process in nitrogen-vacancy (NV) centers in diamond to detect ferromagnetic dynamics at microwave frequencies exceeding the NV spin resonance frequency—previously inaccessible via conventional one-magnon NV relaxometry. The key finding is that a Suhl instability at high microwave powers generates non-equilibrium magnons that drive NV relaxation through two-magnon processes, enabling detection beyond the traditional frequency limit and explaining a previously unexplained field shift in the NV response.

ABSTRACT

The NV center in diamond has proven to be a powerful tool for locally characterizing the magnetic response of microwave excited ferromagnets. To date, this has been limited by the requirement that the FMR excitation frequency be less than the NV spin resonance frequency. Here we report NV relaxometry based on a two-magnon Raman-like process, enabling detection of FMR at frequencies higher than the NV frequency. For high microwave drive powers, we observe an unexpected field-shift of the NV response relative to a simultaneous microwave absorption signal from a low damping ferrite film. We show that the field-shifted NV response is due to a second order Suhl instability. The instability creates a large population of non-equilibrium magnons which relax the NV spin, even when the uniform mode FMR frequency exceeds that of the NV spin resonance frequency, hence ruling out the possibility that the NV is relaxed by a single NV-resonant magnon. We argue that at high frequencies the NV response is due to a two-magnon relaxation process in which the difference frequency of two magnons matches the NV frequency, and at low frequencies we evaluate the lineshape of the one-magnon NV relaxometry response using spinwave instability theory.

Motivation & Objective

  • To extend the frequency range of NV center-based relaxometry beyond the NV spin resonance frequency.
  • To explain an experimentally observed field shift in NV response relative to microwave absorption in low-damping ferrite films at high microwave powers.
  • To demonstrate that the NV response at high frequencies is not due to single-magnon resonance but to a two-magnon relaxation process.
  • To characterize the lineshape of one-magnon NV relaxometry using spin wave instability theory.
  • To establish the role of the Suhl instability in generating non-equilibrium magnons that mediate NV relaxation.

Proposed method

  • Utilizes nitrogen-vacancy (NV) centers in diamond as nanoscale magnetic sensors to probe microwave-excited ferromagnets.
  • Employs a two-magnon Raman-like relaxation process where the energy difference of two magnons matches the NV spin resonance frequency.
  • Analyzes NV relaxation dynamics under high microwave drive powers, identifying deviations from single-magnon behavior.
  • Applies spinwave instability theory to model the one-magnon relaxometry lineshape at low powers.
  • Compares NV response to simultaneous microwave absorption measurements to isolate non-equilibrium effects.
  • Identifies the Suhl instability as the source of non-equilibrium magnon populations that relax the NV spin.

Experimental results

Research questions

  • RQ1Can NV relaxometry detect ferromagnetic dynamics at microwave frequencies above the NV spin resonance frequency?
  • RQ2What causes the observed field shift in the NV response relative to microwave absorption at high microwave powers?
  • RQ3Is the NV relaxation at high frequencies mediated by a single-magnon or a two-magnon process?
  • RQ4How do spinwave instabilities influence the NV relaxation dynamics in ferromagnetic films?
  • RQ5What is the role of non-equilibrium magnons in enabling NV relaxation beyond the conventional frequency limit?

Key findings

  • The NV response at microwave frequencies above the NV spin resonance frequency is enabled by a two-magnon relaxation process, not single-magnon resonance.
  • A field shift in the NV response relative to microwave absorption is attributed to a second-order Suhl instability generating non-equilibrium magnons.
  • The Suhl instability leads to a large population of non-equilibrium magnons that drive NV relaxation even when the FMR frequency exceeds the NV frequency.
  • At low microwave powers, the one-magnon NV relaxometry lineshape is successfully modeled using spinwave instability theory.
  • The two-magnon process allows detection of ferromagnetic dynamics beyond the prior frequency limit of NV relaxometry.
  • The results rule out single-magnon relaxation as the mechanism for the observed NV response at high frequencies.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.