Skip to main content
QUICK REVIEW

[Paper Review] First Commissioning of a Cryogenic Distillation Column for Low Radioactivity Underground Argon

H.O. Back, T. Alexander|arXiv (Cornell University)|Apr 26, 2012
Nuclear Physics and ApplicationsPhysics and Astronomy5 references14 citations
TL;DR

This paper presents the first successful commissioning of a cryogenic distillation column at Fermilab for purifying low-radioactivity underground argon. The system achieved continuous production of 99.9% pure argon with nitrogen contamination below 10 ppm, and batch operation reduced nitrogen to 500 ppm (99.95% purity), with 70–81% argon collection efficiency and a daily production rate of 0.84–0.98 kg.

ABSTRACT

We report on the performance and commissioning of a cryogenic distillation column for low radioactivity underground argon at Fermi National Accelerator Laboratory. The distillation column is designed to accept a mixture of argon, helium, and nitrogen and return pure argon with a nitrogen contamination less than 10 ppm. In the first commissioning, we were able to run the distillation column in a continuous mode and produce argon that is 99.9% pure. After running in a batch mode, the argon purity was increased to 99.95%, with 500 ppm of nitrogen remaining. The efficiency of collecting the argon from the gas mixture was between 70% and 81%, at an argon production rate of 0.84-0.98 kg/day.

Motivation & Objective

  • To develop and commission a cryogenic distillation system for purifying crude underground argon with high nitrogen and helium impurities.
  • To reduce nitrogen contamination in argon to below 10 ppm for use in dark matter detectors.
  • To achieve high-purity, low-radioactivity argon production at a sustainable daily rate.
  • To validate the performance of the distillation column using continuous and batch operation modes.
  • To measure and optimize argon collection efficiency and production rate for future large-scale deployment.

Proposed method

  • The distillation column is a 318 cm stainless steel tube packed with Sulzer Chemtech EX Laboratory Packing, equivalent to 58 theoretical stages.
  • A temperature gradient is maintained via a cryocooler at the top and heaters at the top and reboiler at the bottom to enable fractional distillation.
  • Cryogenic conditions liquefy argon and nitrogen at the column center, with more volatile nitrogen and helium exiting the top and pure argon collected in the reboiler.
  • Gas composition is monitored in real time using a Stanford Research Systems Universal Gas Analyzer (UGA) calibrated for argon, helium, and nitrogen.
  • The UGA measures partial pressures at mass-to-charge ratios 4 (He), 28 (N₂), and 40 (Ar), with no spectral interference among the three gases.
  • Two independent methods—liquid level monitoring and mass flow integration—were used to calculate argon collection efficiency.

Experimental results

Research questions

  • RQ1Can a cryogenic distillation column effectively purify crude underground argon with high nitrogen and helium impurities to meet detector-grade purity standards?
  • RQ2What is the achievable argon purity and collection efficiency in continuous versus batch operation modes?
  • RQ3What is the optimal operating parameter set for minimizing nitrogen contamination in the argon product?
  • RQ4What is the sustainable daily production rate of high-purity argon from the distillation system?
  • RQ5How accurate are independent mass measurement methods (liquid level vs. mass flow) in estimating collected argon?

Key findings

  • The cryogenic distillation column successfully produced argon with 99.9% purity in continuous mode, reducing nitrogen contamination to less than 10 ppm.
  • In batch mode, nitrogen concentration decreased to the UGA detection limit of 500 ppm, corresponding to 99.95% argon purity.
  • Argon collection efficiency was measured between 70% and 81% using two independent methods, with a discrepancy possibly due to calibration uncertainty.
  • The system achieved a daily argon production rate of 0.84–0.98 kg, based on a 5% argon feed and 75% ± 5% collection efficiency.
  • Helium was effectively removed from the system, with nearly all exiting through the waste stream, confirming its high volatility.
  • The UGA-based monitoring system provided reliable, real-time composition tracking with no interference between argon, nitrogen, and helium.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.